wireless CT turn ratio tester

  • ETCR9500B Wireless High Voltage CT Turn Ratio Tester

    Current, transformation ratio, polarity and phase difference test of the transformer and current transformer primary and secondary circuits below 35kV. 1. Model No.: ETCR9500B 2. Turn Ratio Range:1~500 3. Primary Current Test Accuracy: 0.0A~800A/0.1A/ ±0.5%FS 4. Secondary Current Test Accuracy: 0.00mA~5A/0.01mA/ ±0.5%FS 5. CT Size:φ48mm & φ8mm 6. Power Supply: DC6V alkaline batteries LR03 (1.5V AAA X 8)

  • ETCR9500C-008 Three-Channel Wireless High Voltage CT Turn Ratio Tester

    Measurement of primary and secondary current, transformation ratio, phase difference, polarity and phase sequence of current transformers and transformers below 35kV 1. Model No.: ETCR9500C-008 2. Primary Current Test Accuracy : 0.0A~800A/0.1A/±0.5%FS 3. Secondary Current Test Accuracy: 0.00mA~5A/ 0.01mA/ ±0.5%FS 4. Turn Ratio Measurement Range: 1~500 5. Transmission Distance: Primary: 100m; Seconary: 2m cable 6. Power Supply: DC6V alkaline batteries (1.5V AAA × 8)

  • ETCR9500C-030 Three-Channel Wireless High Voltage CT Turn Ratio Tester

    Measurement of primary and secondary current, transformation ratio, phase difference, polarity and phase sequence of current transformers and transformers below 35kV 1. Model No.: ETCR9500C-030 2. Primary Current Test Accuracy : 0.0A~800A/0.1A/±0.5%FS 3. Secondary Current Test Accuracy: 0.00mA~10A/ 0.01mA/ ±0.5%FS 4. Turn Ratio Measurement Range: 1~500 5. Transmission Distance: Primary: 100m; Seconary: 2m cable 6. Power Supply: DC6V alkaline batteries (1.5V AAA × 8)

  • ETCR9620B Wireless Low Voltage CT Turn Ratio Tester

    Leakage current, current, transformation ratio, ratio difference, angle difference, phase difference and polarity test of current transformer primary & secondary circuits in 380V/220V power distribution system. 1. Model No.:ETCR9620B 2. Primary Current Test Accuracy: 0.0A~3000A/ 0.1A/ ±1%FS 3. Secondary Current Test Accuracy : 0.00mA~5A/ 0.01mA/ ±0.5%FS 4. Turn Ratio Measurement Range: 1~500 5. Wireless Transmission Distance: 100M 6. Power Supply : Alkaline batteries (1.5V AAA X 4PCS & 6F22 9V X1PCS)

  • ETCR9550B Wireless H/L Voltage CT Turn Ratio Tester

    Measurement of primary and secondary current, transformation ratio, phase difference, polarity and phase sequence of current transformers and transformers below 35kV 1. Model No.: ETCR9550B 2. Primary Current Test Accuracy : High voltge clamp: 0.0A~800A/0.1A/±0.5%FS Flexible coil clamp: 0.0A~3000A/0.1A/±1%FS 3. Secondary Current Test Accuracy: 0.00mA~5A/ 0.01mA/ ±0.5%FS 4. Turn Ratio Measurement Range: 1~500 5. Transmission Distance: Primary: 100m; Seconary: 2m cable 6. Power Supply: DC6V alkaline batteries (1.5V AAA × 8)