spd ac

  • 275V ac surge protection device 3 phase SPD

    Type 2 surge protector SPD 275V In:20kA Imax: 40kA Low voltage Up Internal disconnection, statue indicator, and remote signaling IEC 61643-11

  • Type 2 ac surge protection device SPD 750V

    Type 2 surge protector SPD 750V In:20kA Imax: 40kA Low voltage Up Internal disconnection, statue indicator, and remote signaling IEC 61643-11

  • Type 1+2 AC surge protection device SPD 15kA

    Type 1+2 AC power surge protector Iimp:15kA In: 30kA Low voltage Up Internal disconnection, statue indicator, and remote signaling IEC 61643-11

  • Type 2 AC SPD 2P 40kA 420V

    Type 2 surge protector In:20kA Imax: 40kA Low voltage Up Internal disconnection, statue indicator, and remote signaling IEC 61643-11 OEM acceptable

  • Class C plug in surge protective device 420V 4poles

    Type 2 surge protector In:20kA Imax: 40kA Low voltage Up Internal disconnection, statue indicator, and remote signaling IEC 61643-11 OEM acceptable

  • JLSP-GA275/80/4P ac spd power surge protective device

    AC surge protective device 275V MAX Vac: 275V IMAX: 80KA RoHS, IEC, UL certificates Phase 4P DIN Rail 35mm Easy to be replaced with pluggable design Packing with inner box to prevent transport vibration

  • surge lightning protection arrester JLSP-BC/25

    AC surge protective device 230V 400V Lightning impluse current (10/350us) 25KA AC network Un: 230/400V Iimp(10/350us): 25KA In(8/20us): 50KA RoHS, IEC, UL certificates Phase 1P, 2P, 3P, 4P DIN Rail 35mm Easy to be replaced with pluggable design Packing with inner box to prevent transport vibration

  • 400v supplier 50ka 230v surge lightning protection arrester

    AC surge protective device 230V 400V Lightning impluse current (10/350us) 25KA AC network Un: 230/400V Iimp(10/350us): 25KA In(8/20us): 50KA RoHS, IEC, UL certificates Phase 1P, 2P, 3P, 4P DIN Rail 35mm Easy to be replaced with pluggable design Packing with inner box to prevent transport vibration

  • surge lightning protection arrester Jinli supplier 50ka 400v

    AC surge protective device 230V 400V Lightning impluse current (10/350us) 25KA AC network Un: 230/400V Iimp(10/350us): 25KA In(8/20us): 50KA RoHS, IEC, UL certificates Phase 1P, 2P, 3P, 4P DIN Rail 35mm Easy to be replaced with pluggable design Packing with inner box to prevent transport vibration

  • Type 2 ac surge protection device SPD 750V

    Type 2 surge protector SPD 750V, U=750V, In:20kA, Imax: 40kA for 690V ac power system Low voltage Up Internal disconnection, statue indicator, and remote signaling IEC 61643-11 OEM/ODM manufacturer Sungrow, Goodwe, Graowatt supplier, work with Huawei

  • Type 1 2 AC surge protection device SPD 15kA

    Type 1+2 AC power surge protector Iimp:15kA In: 30kA Low voltage Up Internal disconnection, statue indicator, and remote signaling IEC 61643-11 OEM/ODM

  • Class C plug in surge protective device 420V 4poles

    Type 2 surge protector, Uc=440V, ac spd three phase Uc=440V, In:20kA, Imax: 40kA Low voltage Up Internal disconnection, statue indicator, and remote signaling IEC 61643-11 OEM/ODM manufacturer Sungrow, Goodwe, Growatt supplier, work with Huawei

  • JLSP-BC/15 surge lightning protection arrester

    AC surge protective device 230V 400V AC network Un: 230/400V Iimp(10/350us): 15KA RoHS, IEC, UL certificates Phase 1P, 2P, 3P, 4P DIN Rail 35mm Easy to be replaced with pluggable design Packing with inner box to prevent transport vibration

  • JLSP-BC/15/4P surge lightning protection arrester

    AC surge protective device 230V 400V AC network Un: 230/400V Iimp(10/350us): 15KA RoHS, IEC, UL certificates Phase 4P DIN Rail 35mm Easy to be replaced with pluggable design Packing with inner box to prevent transport vibration

  • JLSP-BC/25 surge lightning protection arrester

    AC surge protective device 230V 400V Lightning impluse current (10/350us) 25KA AC network Un: 230/400V Iimp(10/350us): 25KA In(8/20us): 50KA RoHS, IEC, UL certificates Phase 1P, 2P, 3P, 4P DIN Rail 35mm Easy to be replaced with pluggable design Packing with inner box to prevent transport vibration

  • JLSP-BC680/12.5 surge lightning protection arrester

    AC surge protective device 460, 277/480, 400/690V AC network Un: 277V-690V Iimp(10/350us): 12.5KA RoHS, IEC, UL certificates Phase 1P, 2P, 3P, 4P DIN Rail 35mm Easy to be replaced with pluggable design Packing with inner box to prevent transport vibration

  • surge lightning protection arrester JLSP-BC680/12.5

    AC surge protective device 460, 277/480, 400/690V AC network Un: 277V-690V Iimp(10/350us): 12.5KA RoHS, IEC, UL certificates Phase 1P, 2P, 3P, 4P DIN Rail 35mm Easy to be replaced with pluggable design Packing with inner box to prevent transport vibration

  • lightning protection ac power spd JLSP-GA175/40/4P

    AC surge protective device 175V MAX Vac: 175V IMAX: 40KA RoHS, IEC, UL certificates Phase: 4P DIN Rail 35mm Easy to be replaced with pluggable design Packing with inner box to prevent transport vibration

  • surge lightning protection arrester JLSP-BC/15/4P

    AC surge protective device 230V 400V AC network Un: 230/400V Iimp(10/350us): 15KA RoHS, IEC, UL certificates Phase 4P DIN Rail 35mm Easy to be replaced with pluggable design Packing with inner box to prevent transport vibration

  • surge lightning protection arrester JLSP-BC/15

    AC surge protective device 230V 400V AC network Un: 230/400V Iimp(10/350us): 15KA RoHS, IEC, UL certificates Phase 1P, 2P, 3P, 4P DIN Rail 35mm Easy to be replaced with pluggable design Packing with inner box to prevent transport vibration

[  A total of  3  pages]