high voltage CT turn ratio tester

  • ETCR9500B Wireless High Voltage CT Turn Ratio Tester

    Current, transformation ratio, polarity and phase difference test of the transformer and current transformer primary and secondary circuits below 35kV. 1. Model No.: ETCR9500B 2. Turn Ratio Range:1~500 3. Primary Current Test Accuracy: 0.0A~800A/0.1A/ ±0.5%FS 4. Secondary Current Test Accuracy: 0.00mA~5A/0.01mA/ ±0.5%FS 5. CT Size:φ48mm & φ8mm 6. Power Supply: DC6V alkaline batteries LR03 (1.5V AAA X 8)

  • ETCR9500C-008 Three-Channel Wireless High Voltage CT Turn Ratio Tester

    Measurement of primary and secondary current, transformation ratio, phase difference, polarity and phase sequence of current transformers and transformers below 35kV 1. Model No.: ETCR9500C-008 2. Primary Current Test Accuracy : 0.0A~800A/0.1A/±0.5%FS 3. Secondary Current Test Accuracy: 0.00mA~5A/ 0.01mA/ ±0.5%FS 4. Turn Ratio Measurement Range: 1~500 5. Transmission Distance: Primary: 100m; Seconary: 2m cable 6. Power Supply: DC6V alkaline batteries (1.5V AAA × 8)

  • ETCR9570 Multifunction H/L Voltage CT Turn Ratio Tester

    Turn ratio measurement; transformation ratio polarity display; voltage measurement; primary current and secondary current measurement; voltage and current waveform display; phase between primary current and secondary current, phase between each current and voltage; frequency measurement; Active power, reactive power, power factor measurement; harmonic measurement. 1. Model No.:ETCR9570 2. Voltage Range:0V~600V 3. Current Sensor Range :0A~3000A/0A~600A/ 0A~10A 4. Turn Ratio Measurement Range: 1~9999 5. Phase Range: 0~360° 6. Hot Power Supply : Lithium battery 7.4V 5200mAH

  • ETCR9500C-030 Three-Channel Wireless High Voltage CT Turn Ratio Tester

    Measurement of primary and secondary current, transformation ratio, phase difference, polarity and phase sequence of current transformers and transformers below 35kV 1. Model No.: ETCR9500C-030 2. Primary Current Test Accuracy : 0.0A~800A/0.1A/±0.5%FS 3. Secondary Current Test Accuracy: 0.00mA~10A/ 0.01mA/ ±0.5%FS 4. Turn Ratio Measurement Range: 1~500 5. Transmission Distance: Primary: 100m; Seconary: 2m cable 6. Power Supply: DC6V alkaline batteries (1.5V AAA × 8)

  • ETCR9550B Wireless H/L Voltage CT Turn Ratio Tester

    Measurement of primary and secondary current, transformation ratio, phase difference, polarity and phase sequence of current transformers and transformers below 35kV 1. Model No.: ETCR9550B 2. Primary Current Test Accuracy : High voltge clamp: 0.0A~800A/0.1A/±0.5%FS Flexible coil clamp: 0.0A~3000A/0.1A/±1%FS 3. Secondary Current Test Accuracy: 0.00mA~5A/ 0.01mA/ ±0.5%FS 4. Turn Ratio Measurement Range: 1~500 5. Transmission Distance: Primary: 100m; Seconary: 2m cable 6. Power Supply: DC6V alkaline batteries (1.5V AAA × 8)