CE Approval Round design LED Driver Sensor 120-240VAC DIP Switch For Ceiling Light
Detailed Product Description
Input voltage |
220~240VAC 50/60Hz |
Input current |
0.3A-0.15A |
Input power |
35 W |
Detection area |
50%/100% |
Hold time |
5s/90s/ 5min/10min |
Daylight threshold |
2Lux /10Lux /50Lux/Disable |
Stand-by period |
0s/10s/10min /+∞ |
Stand-by dimming level |
10%/30% |
Microwave frequency |
5.8GHz±75MHz |
Microwave power |
<0.3mW |
Detection angle |
30°~150° |
Mounting height |
Max.6m(ceiling mounted) Max.3m(wall mounted) |
Detection range |
Max.ø14m(ceiling mounted) Max.10m(wall mounted) |
Output LED current |
0.45A/0.55A/0.60A/0.70A ±5% |
Output LED voltage |
33V~43V DC |
Output LED power |
30W |
Empty load voltage |
≤60V DC |
Power factor |
≥0.9 |
Efficiency |
89% (Max.) |
Operating temperature |
Ta:- 20°C~50°C Tc: 85°C |
Abnormal protection |
SCP:Auto recovery,OVP,OCP,OTP |
EMC standard |
EN55015 |
Safety standard |
EN61347-1 EN61347-2-13 EN60598-1 |
IP rating |
IP20 |
Life time |
30,000 hours |
Warranty |
3 years |
Wiring diagram
Mechanical structure(mm)
Lux on/off
Adopted dual PD technology, HT30VR is able to differentiate artificial light brightness from natural light after installed inside the fixture, and automatically turn off light
when ambient brightness exceeds preset lux level.
Preconditions to use the Lux-off function:
1. Standby period is +∞;
2. Standby dimming level is on 10%, 20% or 30%;
3. Daylight threshold is on 30Lux, 50Lux, 80Lux or 120Lux.
Demo
Application