Heat-absorbing and Fireproof Blanket KC9000

Sales Heat-absorbing and Fireproof Blanket KC9000

KC9000 heat-absorbing and fireproof blanket is a fireproof product that can be directly coated on the external protection of equipment, power cable, cable bridge, etc., which can effectively prevent flame spread and reduce the serious damage caused by high temperature conduction.

Product Detail  

Product Instruction

KC9000 heat-absorbing and fireproof blanket is a fireproof product that can be directly coated on the external protection of equipment, power cable, cable bridge, etc., which can effectively prevent flame spread and reduce the serious damage caused by high temperature conduction. In case of fire, the product can resist the high temperature flame above 1000℃, and release chemical crystal water to absorb a lot of heat, effectively reduce the surface temperature of the protected facilities, and provide adequate emergency response time for the protection of the facilities.


Product Features

  • Class A non-combustible material, excellent fire performance
  • Low thermal conductivity, excellent thermal insulation performance
  • Crystal water can be released at high temperature, effectively reducing the space temperature
  • No powder or slag after coating
  • Can be cut arbitrarily, the construction is efficient and convenient
  • Environment-friendly material, non-toxic and harmless


Applications

  • Cable bridge and other steel structure
  • Power wires, cables, intermediate joints, etc.
  • Cable busbar
  • Equipment package


Technical Parameters

 

No.

Test Item

Typical Value

Test standards

1

Tensile Strength,kPa

≥600(Coated metal foil)

GB/T 17911-2018

2

Combustion performance

A

GB 8624-2012

3

Coefficient of thermal conductivity,W/m·k,500℃

0.069

YB/T 4130

4

Bulk density

400、600、800

/

5

Fire performance

2h None of the fuses or circuit breakers are disconnected and none of the bulbs remain on

In accordance with the IEC 60331-1:2018 Integrity tests for cables under flame condition - Part 1: Test method for fire supply and impact of cables with a rated voltage up to 0.6/1kV and an outer diameter exceeding 20mm by flame temperature not less than 830℃


Direction for Use

1. Measure the size according to the on-site installation environment;
2. Cut with electric scissors;
3. Wrap the cut fire blanket on the pipe fittings;
4. Use refractory aluminum foil tape for edge sealing;
5. The stainless steel cable tie is fastened and shaped


Product Specification

型号

Specifications

Package

Width(mm)

Thickness(mm)

Length(m)

Model

610

10

6

1 roll/box

 


Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
X

Home

Supplier

Leave a message

Leave a message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.