>Bypass charging function: when the unit off,it can be activated with bypass output and can charge the battery.
>High charging current,the max charging current can be 200A for IVPA10048 and 180A for IVPA7548,170A for IVPA5048,120A for IVPA3524.
>Wide range of AC input voltage:the range of AC input voltage can be 90-280V for IVPA7548 and IVPA10048,80-140V for IVPA5048 and IVPA3524.It can be better compatible with generator working.It is rare to have wide rang input voltage for the power frequency inverter.
>Electricity and battery priority is optional:customer can choose Electricity or battery priority according to their needs.
>Battery self-defined:customer can set the overcharge voltage and float voltage,and over-discharge voltage.
>50/60HZ compatible.
>Intelligent: Intelligent adjustment of over-discharge voltage,intelligent fine-tuning of over-discharge voltage according to the power of the load; intelligent cooling fan, intelligent adjustment of speed according to power and charging current and core temperature inside the machine.
>Safety: Safety design is upgraded overall. Comprehensive protection(Among them,transformer over-temperature protection is a leading design in the industry).
>Later it can communicate with our MPPT. And the electricity charging and solar charging can be managed comprehensively and scientifically.
Advantage:
1. Protect personal safety
2. Temperature compensation, protect battery
3. Battery overcharge, discharge protect
4. Inverter over load, output short circuit protect
5. Over temperature protect
6. Transposition protect
7. AC input, output over-current protect
8. Charge short circuit protect
Date Sheet
Model
IVPA3524
IVPA5048
IVPA7548
IVPA10048
Rated Output Power(VA)
3500VA
5000VA
7500VA
10000VA
Rated Output Power(W)
2800W
4000W
6000W
8000W
Nominal DC Input Voltage
24V
48V
48V
48V
Input Voltage Waveform
Sinusoidal(Utility or generator)
Teriminal connection
L N
HOT1 HOT2
Low Line Disconnect
170Vac±7V(UPS)
90Vac±7V(Appliances)
Low Line Re-connect AC Input Range
180Vac±7V(UPS)
100Vac±7V(Appliances)
High Line Disconnect
280Vac±7V
High Line Re-connect
270Vac±7V
Max AC Input Voltage
280Vrms
Nominal Input Frequency
50Hz/60Hz
Low Line Frequency Disconnect
40±1Hz
Low Line Frequency Re-connect
42±1Hz
High Line Frequency Disconnect
65±1Hz
High Line Frequency Re-connect
63±1Hz
Output Voltage Wave form
Synchronize with input voltage
Over-Load Protection(SMPS load)
Overcurrent protector
air switch protection
Overcurrent protector
air switch protection
Output Short Circuit Protection
Overcurrent protector
air switch protection
Overcurrent protector
air switch protection
Efficiency(Line mode)
≥95%
Transfer Time (AC to DC)
15ms (typical value)
Transfer Time (DC toAC)
15ms (typical value)/30ms (special value)
Pass Through Without Battery
NO
Overcurrent Protector (grid)
50A
63A
63A
63A
Utility Charge Mode Specificati
Nominal Input Voltage
80- 140Vac
90-280Vac
Input Voltage Range
Depends On The Battery Type
Nominal Output Voltage
40A
50A
60A
80A
Max Charge Current
0-40A
0-50A
0-60A
0-80A
Charge Current Regulation
Circuit breaker
Battery Initial Voltage
50A
63A
63A
63A
Charger Short Circuit
Dependent on battery type or self-defined
Breaker Size
YES
Product Detail
Installation Procedure:
1. Insure the DC voltage of inverter in accordance with the battery voltage.
2. Insure the positive pole (red)of inverter connect with the positive pole (red) of battery, and the negative pole (black) of inverter connect with the negative pole (black) of battery, then tighten the screw.
3. Turn on the inverter and see if it is good, if good then turn off.
4. Connect with AC power / Ground wire, turn on the inverter and see if it is working normally (charge the battery, show charge current) if so, turn off the inverter.
5. Connect with the load/ground wire and turn on the inverter (Power saver auto or Power saver off ).
6. Turn on the Load.
Certification