Advantage:
1. Bypass charging function,AC charge available when the unit off
2. 90-280V AC Widely input voltage Grid electricity and battery power priority is optional.
3. Higher charge current and adjustable Communicate with our MPPT charge controller.
4. Intelligent protection, high class of security.
Date Sheet
Model | IVPA3524 | IVPA5048 | IVPA7548 | IVPA10048 |
Rated Output Power(VA) | 3500VA | 5000VA | 7500VA | 10000VA |
Rated Output Power(W) | 2800W | 4000W | 6000W | 8000W |
Nominal DC Input Voltage | 24V | 48V | 48V | 48V |
Input Voltage Waveform | Sinusoidal(Utility or generator) | |||
Teriminal connection | L N | HOT1 HOT2 | ||
Low Line Disconnect | 170Vac±7V(UPS) | 90Vac±7V(Appliances) | ||
Low Line Re-connect AC Input Range | 180Vac±7V(UPS) | 100Vac±7V(Appliances) | ||
High Line Disconnect | 280Vac±7V | |||
High Line Re-connect | 270Vac±7V | |||
Max AC Input Voltage | 280Vrms | |||
Nominal Input Frequency | 50Hz/60Hz | |||
Low Line Frequency Disconnect | 40±1Hz | |||
Low Line Frequency Re-connect | 42±1Hz | |||
High Line Frequency Disconnect | 65±1Hz | |||
High Line Frequency Re-connect | 63±1Hz | |||
Output Voltage Waveform | Synchronize with input voltage | |||
Over-Load Protection(SMPS load) | Over current protector | air switch protection | Over current protector | air switch protection |
Output Short Circuit Protection | Over current protector | air switch protection | Over current protector | air switch protection |
Efficiency(Line mode) | ≥95% | |||
Transfer Time (AC to DC) | 15ms (typical value) | |||
Transfer Time (DC toAC) | 15ms (typical value)/30ms (special value) | |||
Pass Through Without Battery | NO | |||
Over current Protector (grid) | 50A | 63A | 63A | 63A |
Utility Charge Mode Specificati | ||||
Nominal Input Voltage | 80- 140Vac | 90-280Vac | ||
Input Voltage Range | Depends On The Battery Type | |||
Nominal Output Voltage | 40A | 50A | 60A | 80A |
Max Charge Current | 0-40A | 0-50A | 0-60A | 0-80A |
Charge Current Regulation | Circuit breaker | |||
Battery Initial Voltage | 50A | 63A | 63A | 63A |
Charger Short Circuit | Dependent on battery type or self-defined | |||
Breaker Size | YES |
Product Detail
Installation Procedure:
1. Insure the DC voltage of inverter in accordance with the battery voltage.
2. Insure the positive pole (red)of inverter connect with the positive pole (red) of battery, and the negative pole (black) of inverter connect with the negative pole (black) of battery, then tighten the screw.
3. Turn on the inverter and see if it is good, if good then turn off.
4. Connect with AC power / Ground wire, turn on the inverter and see if it is working normally (charge the battery, show charge current) if so, turn off the inverter.
5. Connect with the load/ground wire and turn on the inverter (Power saver auto or Power saver off ).
6. Turn on the Load.
FQA
Q :Can we use this inverter with AC electricity?
A :Yes, Felicitysolar pure sine wave inverter can hybrid AC, generator, solar, UPS electricity.
Q :If we use DC and AC electricity both, which one will be first?
A :Felicitysolar pure sine wave inverter is AC first.
Q :How about the efficiency of this inverter
A :Felicitysolar pure sine wave inverter has 80% power efficiency.
Q : What kind of certification of this inverter you have?
A :We have many certification, IEC certification by Beide Compliance Loboratory, SONCAP by CIC,etc.