1 Features
Compatible with APEX SA50、MSK MSK4200 |
|
Continuous output current 5A |
|
Peak current 7A |
|
Analog DC signal input 4V~8V |
|
High efficiency :97% |
|
TO-3 Package |
Absolute maximum rating |
Recommended operating conditions |
Supply voltage+VS:80V Supply voltage+VCC:16V Internal power loss:60W Storage temperature:-65~+150℃ Input voltage,VIN:+VCC
|
Supply voltage+VS:28V Supply voltage+VCC:12V Input voltage,+V1:4V~8V operating temperature:-55℃~+125℃
|
No |
Character |
conditions VS=28V±1.4V VCC=12V±1V RL=1KΩ RSENSE A、RSENSE B\GND -55℃≤Tc≤125℃ |
HSA50 |
Symbol |
|
min Typical value |
max |
||||
1 |
Static current |
V1=6V(DC) |
- |
20 |
mA |
2 |
Turn-on voltage |
IO=5A |
- |
2.4 |
V |
3 |
shut-off leakage current |
Output shutoff,Vs=70V no load |
- |
250 |
μA |
4 |
Switching frequency |
VI=6V(DC) |
40 |
50 |
KHZ |
TC=25℃ VI=3V(DC),duty factor0% |
B ON /A OFF |
|
|
||
5 |
Duty factor A |
TC=25℃,VI=6V(DC) |
40 |
60 |
% |
TC=25℃, VI=9V(DC) duty factor 100% |
A ON/B OFF |
|
|||
TC=25℃, VI=3V(DC) duty factor 100% |
B ON /A OFF |
|
|||
6 |
Duty factor B |
TC=25℃,VI=6V(DC) |
40 |
60 |
% |
TC=25℃, VI=9V(DC) duty factor 0% |
A ON/B OFF |
|
No |
symbol |
Designation |
No |
symbol |
Designation |
1 |
RSENSE B |
Inductor B |
5 |
RSENSE A |
Inductor A |
2 |
BOUT |
Output B |
6 |
+VCC |
power |
3 |
+VS |
Power |
7 |
GND |
Ground |
4 |
AOUT |
Output A |
8 |
Input |
Analog input signal |
Symbol |
Data/mm |
||
|
Min |
Typical |
Min |
A |
- |
- |
6.35 |
A1 |
- |
- |
2.70 |
Φb |
0.90 |
- |
1.10 |
ΦD |
- |
- |
25.65 |
ΦD1 |
- |
- |
22.20 |
α |
- |
40 |
- |
X1 |
29.95 |
- |
30.35 |
X |
- |
- |
39.22 |
L |
11.70 |
- |
- |
ΦP |
3.80 |
- |
4.20 |