Type E thermocouple wire

Sales Type E thermocouple wire

Type E bare thermocouple wire develops the highest source voltage(EMF) per℃ for measuring tiny temperature shift,it is suitable in oxidizing or inert gas atmospheres up to 900℃(ASTM E230:870℃),  The composition of positive(EP) is Ni90Cr10, negative(EN) is Cu55Ni45.

 

  • TYPE : EP/EN
  • DIA : 0.10-8.0mm

Product Detail  

SPECIFICATIONS DETAILS

Specification

EMF(mv)

100

200

400

600

800

NiCr(EP)

2.784~ 2.844

5.938~ 6.002

12.709~ 12.819

19.537~ 19.699

26.102~ 26.308

 

2.814

5.97

12.764

19.618

26.205

CuNi(EN)

3.467~ 3.543

7.410~ 7.492

16.109~ 16.255

25.362~ 25.588

34.664~ 34.960

 

3.505

7.451

16.182

25.475

34.812

NiCr-CuNi

6.251~ 6.387

13.348~ 13.494

28.818~ 29.074

44.899~ 45.287

60.766~ 61.268

 

6.319

13.421

28.946

45.093

61.017

Physical parameters

Specification 

Density (g/cm3)

MP(℃) 

TS(mpa) 

Extensibility 

Resistivity (20℃μΩ.m)

NiCr(EP)

8.5

1427

490

10

0.71

CuNi(EN)

8.5

1220

390

25

0.5




 

QUALITY GUARANTEE

SICC can supply type E thermocouple wire material meet the accuracy standard IEC60584 and ASTM E230. The advanced melting skills combined controls the chemical composition to achieve the highest quality products , our produce base has the capacity of 900 tons annual with 35000 square meters that can meet your comprehensive requirements. Whatever the bright annealed or oxidized conditions, all thermocouple conductors are calibrated at our lab ,this includes the testing of EMF, chemical composition, physical and thermoelectric properties before shipment.

 

SICC provides calibration results for all bare thermocouple wires with each shipment, including EMF values, accuracy, batch number, raw materials chemistry, lab environment condition,etc. Each order has only one job number for tracement. Calibration capability is available up to 1000C on suitable thermocouple types.

Our lab routinely calibrates at the following fixed points:100C,200C,400C,600C,800C for type E thermocouple materials, we work continuously to reduce the measurement uncertainty at each calibration temperature and new estimates are made every six months to ten months, ensuring any deviations are identified early so that results generated by the lab remain consistent and accurate.

 

Contact us today for your any requirements.

 

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
X

Home

Supplier

Leave a message

Leave a message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.