Solar Light Energy Storage System of LifePO4 Battery Packs

Sales Solar Light Energy Storage System of LifePO4 Battery Packs

Solar Light Energy Storage LifePO4 Battery:Long-lasting,maintanance-free, prolonged cycle life,competitive price,no necessary to change the battery all the time.

Product Detail  

Product Item:Solar Light Energy Storage System of LifePO4 Battery Packs

Main Features

  • Revolutionary cutting-edge technology of maintenance-free and long-lasting solar light energy storage system;
  • Prolonged cycle life of LiFePO4 battery up to 6,000 times, equivalent to working life of solar panels and LED lamp;
  • Made of automotive-grade lithium iron phosphate cells and high efficiency solar integrated controller;
  • World's first-class brand components for boost system, together with industrial single microchip to achieve programmable control;
  • 384Wh (3.2V120AH), equivalent to 12.8V30AH system.


Specifications

Item

Parameters

Notes

Total EnergyWh

384


Nominal VoltageV

3.2


Nominal CapacityAh)

120


Standard Charge CurrentA

20

Adjustable

Max. Charge CurrentA

30

Recommended

Charge Cutoff VoltageV

6.0

5-6V solar panel power150W

Charge Cutoff CurrentA

1

Adjustable

Standard Discharge CurrentA

0.9

28-38V 0.9A direct drive LED light

Max. Continuous Discharge CurrentA

75

Recommended

Discharge Cutoff VoltageV

2.5

Battery voltage

Impedance

1

Between the positive and negative of the battery

Outer Case

ABS


Dimensionsmm

260(L)*185(W)*95(H)

Outer case size

Weightkg

3.4KG

Outer case weight

Working Temperature

-2055


Storage Temperature (

-4055


Working Condition MoistureRH

≤85%


Storage Condition MoistureRH

5%95%


Wires&Connectors

Charge:12AWG wire+ waterproof connector

LED:16AWG wire+waterproof connector



Detail Pictures 



Other Features

Test Conditions, Methods and Performance

1. Test conditions

All tests were conducted at temperature of 25 ° C, humidity of 25% ~85%, and atmospheric pressure of 86 kPa~106 kPa unless otherwise specified.

2.Measuring instruments

  •     Voltage: DC voltmeter of accuracy ≥0.5,inner resistance≥ 1kΩ / V;
  •    Current: DC meter of accuracy≥0.5;
  •    Temperature: thermometer of appropriate range;the scale value should not be greater than 1℃;
  •    Time: Timing meter to show hour, minute, and second,with ± 1% accuracy

3. Standard charging

Charge with a DC power supply (switching power supply) at voltage of 5.0V, 20C (A) constant current until the current down to 1A.

4. Standard discharge

After charging in accordance with (3.3), discharge at 0.9 (A) current till cutoff.

5. Battery capacity

Discharge in accordance with (3.4), and record discharge time(h), energy (Wh) = power (W) * discharge time (h).


6. Electrical Characteristics

Item

Test Instructions

Criteria

Normal Temp. Performance

Full charge in accordance with (3.3), store at 20±5 for 2h, then discharge in accordance with (3.4)

Discharge time 240min;

No fire,no explosion

 High Temp. Performance

Full charge in accordance with (3.3), store at 55±2 for 2h, then discharge in accordance with (3.4)

Discharge time 240min;

No fire,no explosion

 Low Temp. Performance

Full charge in accordance with (3.3), store at -20±2 for 2h, then discharge in accordance with (3.4)

Discharge time 150min;

No fire,no explosion

Normal Temp. Capacity Retention

Full charge in accordance with (3.3), store at 20±5 for 30 days, then discharge in accordance with (3.4)

Capacity retention:≥95%

C-rate Discharge Performance

Full charge in accordance with (3.3), standby at room temperature for 10min, and then discharge at 1C current till cut-off voltage at 2.5V, record the discharge capacity

Discharge capacity≥90%

Cycle Life

Full charge the battery in accordance with (3.3)at 20 ℃ ± 5 ℃, standby for 5min, and then then discharge in accordance with (3.4) till termination conditions;

Repeat the cycle;

Detect battery capacity every 25 cycles according to the standard charge and discharge test.

When the capacity is  80% of the rated, cycle life2000;

When the capacity is  60% of the rated, cycle life6000;


7. Environmental Performance

Item

Test Conditions

Criteria

Constant Temperature & Constant Heat Experiment

Full charge the battery in accordance with (3.3) and then store it open-circuit at the conditions of temperature of 40 ℃ ± 2 ℃, relative humidity 90 ~ 95%  for 48 hours;

Then return to the temperature condition of 20 ℃ ± 5 ℃, relative humidity of 25% to~ 85%

Discharge  in accordance with (3.4)

The battery pack has no obvious deformation, corrosion, smoke or explosion; discharge capacity is greater than 80% of rated.

Temperature Impact

After the battery pack is charged as required by 3.3,place it open-circuited in the oven;

1) Keep it at -40 ℃ ± 2 ℃ low temperature for 120min;

2) Then raised till 75 ° C ± 2 ° C at a rate of 10 ° C / min;

3) Maintain 75 ℃ ± 2 ℃ high temperature for 120min;

4) Drop the temperature till -40 ° C ± 2 ° C at a rate of 10 ° C / min

Repeat the cycle for 4 times,and then restore to room temperature;

remove the battery pack from the oven, standby at 25 ℃ for  120min till the lithium battery return to room temperature.

No deformation, nor cracking, nor leakage ;

Open circuit voltage, charge capacity are in line with the product specifications, and the battery can still be normally charged and discharged.


8.Safety Tests

Item

Test Instructions

Criteria

Crush Test

The battery pack is charged as required by 3.3 ;

placed between the two extruded surfaces; 

gradually increasing the pressure at 2KN;

keep for 1min.

No fire, no explosion

Acupuncture Test

Fully charge the battery pack according to the provisions of 3.3; 

Place the thermocouple in the battery pack;

Acupuncture through the center of battery pack with a Ф5 stainless steel needle at a speed of 20-40mm / s.

No fire,no explosion,no leakage 

Short-Circuit Test

After the battery pack is charged in accordance of 3.3;

Keep for 1 h at 20 ° C ± 5 ° C;

Short-circuit the battery pack for 10min ( external resistance <10mΩ).

No fire,no explosion,no leakage 

Drop Test

After standard charging according to 3.3,the battery pack is kept in condition of 20 ° C ± 5 ° C for 1 h; and free fall the battery  from a height of 1.5m to the wooden floor.

No fire,no explosion,no leakage 

Over Charge Test

Remove BMS,charge the battery pack at  10A / 30V CC CV until one of the single cells voltage is higher than 5V at 20 ℃ ± 5 ℃ ambient temperature.

No fire,no explosion,no leakage 

Over Discharge Test

Remove BMS, discharge the battery pack at 0.5C (60A) current till the voltage drops to 0V at 20 ℃ ± 5 ℃ ambient temperature.

No fire,no explosion,no leakage 


 Storage, maintenance and transportation

1 Storage

When the battery pack is to be stored for a long time, charge the battery pack to about 50% of SOC (charging about 2 hours at 30A CC after discharging), and place it in a clean, dry and ventilated place, avoid of contact with corrosive substances, away from fire and heat. Charge/discharge cycle the battery pack every three months.

2 Transportation

The battery pack should be packed with care before transport. Truck, trains, ships, airplanes and other means of transport are permitted for transportation of the battery packs.The cargo should be prevented from severe vibration, shock or squeeze,and sheltered from sun and rain during transportation.

3 Maintenance

  • The recommended storage SOC is 40%-60% of rated;
  • It is recommended to charge (at 10A for2 hours ) the battery pack every 6 months for long time storage;
  • Please do not re-assemble the battery pack without the manufacturer’s guidance during maintenance in case of performance deterioration;
  • Please do not disassemble the battery pack; and dissection of the cells is strongly forbidden.

Usage Precautions

1 Do not reverse the polarity to prevent short circuit;

2 Do not put the battery pack into water or soak it;

3 Do not charge the battery pack in hot conditions; Do not use or store batteries near heat sources such as fire or heaters;

4 Do not use nails or other sharp objects to pierce the battery pack;hammering or stamping on the battery packs is prohibited.

5 It is forbidden to disassemble the battery packs or cells in any way;

6 If any anomaly should occur to the battery pack such as odor spreading, heat, deformation, discoloration , remove the battery pack immediately from the appliance or charger, and contact the manufacturer;

7 If the electrolyte of battery leaks accidentally and happens to splash into the eyes, do not wipe, but immediately rinse them with water instead, and seek medical assistance in a timely manner for serious cases.

8 Ambient temperature will affect the discharge capacity. If the ambient temperature exceeds the standard environment range(25 ℃ ± 5 ℃), the discharge capacity will be slightly reduced.

Product liability

1 KOK shall not be liable for any accidents resulting from violation of the operation specified in the specifications;

2 The contents of this specification are subject to change without notice due to the improvement of product quality or the upgrading of relevant technical parameters. For the latest product information, please contact our company


Applications



Pakage: OEM gift box. We can baranding OEM design for you

Come and get one. Email us at market@kokpower.com, call us at 0086-755-2937 1122; or you can send us message below, we will reply you in time.

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
X

Home

Supplier

Leave a message

Leave a message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.