◆IPX8 class, stable and long-life during operation
◆Easy to install, only two steps (Cover, pull)
◆Fast installation, only 15-30 seconds needed to seal one connection
◆No limitation of spare space, especially design for MIMO &massive MIMO Antenna, also convenient to deploy on wall-mounted, high tower, pole-mounted condition etc.,
◆Easy to uninstall, only need knife to cut tube open
◆No skill required by engineers, uniform quality after installation, stable and good sealing and weatherproofing performance
◆Much time cost, and labor cost saving
◆Good operating capability under extreme cold and hot condition, highland, salt-mist situation, heavy windy weather, and anti-UV, anti-ozone
En-CST is new silicone rubber cold shrink tube with special appearance. It’s specially designed to improve silicone cold shrink tube’s resistance to puncture and other external damage. It is also for weatherproofing protection on cable connections or joint, mostly applied on cell sites, such as connection between jumper cable and connector (7/16 DIN, N type or 4.3-10 connector) on RF equipment (RRU, Antenna and passive device), and joint between feeder and jumper cable. Comparing with tape sealing protection, time of installation is much shorter (15-30 seconds), more convenient, uniform waterproofing quality.
Applications
1. It is widely used for waterproof seal in coaxial cables on telecommunication base stations, N-type connector, 1/2 jumper, Din head and 1/2 jumper connector;
2.It can be used as a waterproof seal for cable television connector;
3. It can be used as a waterproof seal for connecting wires and cables;
4.Insulation seal for other types of connection;
Property
Item |
Parameter and Result |
Test Method |
|
Waterproof |
Class |
Pass, IPX8 |
IEC 60529:1989+A1:1999+A2:2013; 1 meter depth in water, duration: 8 hours |
Physical and mechanical properties |
Shore Hardness |
A/41/1 |
ASTM D2240-15 |
Tensile Strength |
9.89 MPa |
ASTM D412-15aMethod A |
|
Elongation |
910% |
ASTM D412-15aMethod A |
|
Tear Strength |
46.2 KN/m |
ASTM D624-00(2012) |
|
Brittleness temperature by impact |
Pass |
ASTM D746-14 |
|
Flammability |
Horizontal burning |
HB |
UL 94-2013 Rev.6-2016 Section 7 |
Temperature |
Installation temperature |
-40℃ - 60℃ |
|
Operation temperature |
-60℃ - 90℃ |
||
Stock temperature |
-60℃ - 90℃ |
Note:Not for specifications. Values are typical, not to be considered minimum or maximum.
Mode |
I.D (mm) |
Relaxed I.D (mm) |
Relaxed Length (mm) |
Description |
en-CST-40 |
≥38 |
≤12 |
≥140 |
Cold Shrink Tube, designed for 1/2" jumper to equipment, only applicable for 7/16 DIN or 4.3-10 connector |
en-CST-28 |
≥27 |
≤12 |
≥110 |
Cold Shrink Tube, designed for 1/2" jumper to equipment, only applicable for 4.3-10 or Type N connector |
en-CST-AISG |
≥22 |
≤10 |
≥110 |
Cold Shrink Tube, applicable for AISGcable to RET |