sewage source heat pump
“Hstars”screw-type sewage source heat pump unit is mainly based on water energy, and meets the needs of winter heating and summer cooling through advanced water source heat pump central air conditioning system. The system is approximately 50% energy efficient compared to conventional air conditioning heating systems.
Brand: Hstars
Cooling capacity range: 98kw ~ 7931kw; heating range: 119kw ~ 9142kw
Applications: hotels, hospitals, sauna bath centers, factory and other areas.
sewage source heat pump
Brief introduction: “Hstars”screw-type sewage source heat pump unit is mainly based on water energy, and meets the needs of winter heating and summer cooling through advanced water source heat pump central air conditioning system. The system is approximately 50% energy efficient compared to conventional air conditioning heating systems.
Brand: Hstars
Cooling capacity range: 98kw ~ 7931kw; heating range: 119kw ~ 9142kw
Applications: hotels, hospitals, sauna bath centers, factory and other areas.
Technical Parameters:
Cooling capacity range 98kw ~ 7931kw Heating range 119kw ~ 9142kw
Application areas Hotels, hospitals, sauna bath centers, factories and other areas.
First, the unit features:
1. The water source heat pump system can be cooled and heated, and one machine can be used for multiple purposes: one system can replace the original two sets of devices or systems of boiler and air conditioner: it saves a lot of energy and also reduces the initial investment of equipment.
2. There is no need for boiler room system for heating, no cooling tower is needed for cooling, and no pollution or emission is realized during use.
3, the unit energy efficiency ratio is high. 1KW of energy can be used for heating and cooling in the area of 6-10 square meters, which is 30%-80% more energy efficient than general central air conditioning.
4. The constant temperature of the water body makes the heat pump unit run more reliable and stable, ensuring the system's high efficiency and economy without special maintenance or operation, and running and maintenance costs are minimal.
5, each thousand square meters of buildings with large units of machine room area of 30-40 square meters, box units can be placed on the balcony or small storage room.
6, all air-conditioning systems have micro-computer precise control, the host and the circulation pump, submersible pump and other ancillary equipment are connected to the network, the user can independently charge, independently adjust the water temperature, room temperature, adjust the start-stop time or remote monitoring.