♦50-hour battery (rechargeable), 4.3'' color LCD mult-line display all integrated into a rugged, watertight enclosure.
♦± 0.5% high accuracy flow measurement.
♦Data logger function.
♦The heat measurement function by configuring with paired temperature sensors.
♦Non-invasive transducers.
♦Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range: -35℃~200℃.
♦Works reliably in both clean and somewhat dirty liquids with turbidity<10000ppm.
♦Lightweight and easily transportable in box.
♦With the ability of Dynamic zero.
SCH-TF1100-DP Portable Dual Channels Clamp On Ultrasonic Flow Meters
The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Two pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.
This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.
Specifications: Transmitter
Measurement principle | Ultrasonic transit-time difference correlation principle |
Flow velocity range | 0.01 to 15 m/s, bi-directional |
Resolution | 0.1mm/s |
Repeatability | 0.15% of reading |
Accuracy | ± 0.5% |
Response time | 0.5s |
Sensitivity | 0.001m/s |
Damping of displayed value | 0-99s(selectable by user) |
Liquid Types Supported | Both clean and somewhat dirty liquids with turbidity <10000 ppm |
Power Supply | AC: 85-265V Up to 50 h with fully charged internal batteries |
Enclosure type | Portable |
Degree of protection | IP65 according to EN60529 |
Operating temperature | -20℃ to +60℃ |
Housing material | ABS |
Display | 4.3'' color multi-line LCD display |
Units | User Configured (English and Metric) |
Rate | Rate and Velocity Display |
Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
Thermal energy | unit GJ,KWh can be optional |
Communication | 4~20mA (accuracy 0.1%),OCT, Relay, RS485 (Modbus RTU), Data Logger, GPRS/GSM |
Security | Keypad lockout, system lockout |
Size | 270X215X175mm |
Weight | 3kgs |
Specifications: Transducer
Degree of protection | IP65 according to EN60529.(IP67 or IP68 Upon request) |
Suited Liquid Temperature | -35℃~200℃ |
Pipe diameter range | 20-50mm for type B, 40-5000mm for type A |
Transducer Size | Type B 40(h)*24(w)*22(d)mm |
Type A 46(h)*31(w)*28(d)mm | |
Material of transducer | Aluminum + Peek |
Cable Length | Std:5m |
Temperature Sensor | Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1% |
FAQ
Can you produce according to the samples or drawings?
Yes, we can produce by your samples or technical drawings. We can build the molds
What is the lead time?
For standard models, lead time is about 3~5 days after order confirmed and payment received.
For OEM orders, the delivery is about 2~3 weeks after data confirmed and payment received.
How to solve the quality problems after sales?
Take photos or videos of the problems and send to us.
We will make a satisfied solution for you within 24 hours after we confirm the problems.