1. 7-digit digital tube, intuitive and clear page
2. Button modification is light and convenient
3. Simple and elegant, smooth to the touch
4. Use it directly without programming
5. 232 communication PLC can be adapted, specially designed for small equipment
PLC Industrial Control Board OP320 All-in-one Machine Text Display
This is a domestic PLC industrial control board and all-in-one parameter display text display. It can be used directly without programming. It has a wide range of applications and can be adapted to 232 communication PLCs. It is specially used for small equipment.
Technical Specification
Operating Voltage | DC 5—30V |
Working current | DC24 50ma |
Dimensions | 98*58mm |
Inner frame size | (It is recommended to drill holes)95.8*55.8mm |
Support PLC type | 三菱FX 232全部系列 |
Operating temperature | —20至80°C |
Number of digital tubes | Double row of 7 digital tubes(0—9999999) |
Bit display | Double row of 7 digital tubes |
Key input | 4 button input |
Sound prompt | 1 buzzer |
Display method | English + characters + numerical values can be displayed in combination |
Parameter setting range | D600Start setting up |
Display occupied address | D100—D121 |
MT all-in-one machine memory address reference
display buffer | D109 bit definition | ||||
D100 | Digital H | Display value 0-9999999 D103=10 does not display the value |
D109.0 | LED 0 | |
D101 | Digital L | D109.1 | LED 1 | ||
D102 | Decimal point position in the upper row | D109.2 | LED 2 | ||
D103 | Show additional | D109.3 | LED 3 | ||
D104 | Next number H | Display value 0-9999999 D103=10 does not display the value |
D109.4 | LED 4 | |
D105 | Lower number L | D109.5 | LED 5 | ||
D106 | Lower decimal point position | D109.6 | LED 6 | ||
D107 | Number of digits displayed below | D109.7 | Disable setting | on cannot enter the setting | |
D108 | Set parameter length limit | How many digits should D600 start setting? | D109.8 | ||
D109 | LED lights, speakers | D109.9 | Monitor brightness | onHighlight display | |
D110 | Top row characters 1,2 | display characters Corresponds to 1-7 digital tubes respectively |
D109.10 | Button horn | The on button will sound for 0.3 seconds |
D111 | Top row characters 3,4 | D109.11 | horn sound | on the horn sounds | |
D112 | Top row characters 5,6 | ||||
D113 | Top row character 7 | ||||
D114 | Lower row characters 1,2 | display characters Corresponds to 1-7 digital tubes respectively |
|||
D115 | Lower row characters 3,4 | ||||
D116 | Lower row characters 5,6 | ||||
D117 | Lower row of characters 7 | ||||
D120 | Write key value | D120 key value | |||
D121 | Current setting number | Display current setting number | D120.0 | SET | Press and hold SET IF for 1.5 seconds to enter Or exit the settings and go to the settings mode Press SET UF under the formula to change Set number, press +- to change Change the setting value, the value is from D600 start |
D120.1 | |||||
D600 | Set content 0 | D120.2 | 十 | ||
D601 | Setting content 1 | D120.3 | 一 | ||
D6xx | Set contentxx |
Basic Settings
parameter settings
1.Long press ( 3 seconds
2.The upper row displays the set value and the lower row displays d600.
3. Press the +-- buttons to adjust the upper row value size.
4.press to adjust the d600 number in the lower row.
5. Press and hold for 3 seconds to exit settings L wiring table.
How to display English characters
1.Use the following software to select "共阴"
2.the segment needs to be displayed at the midpoint of the display box
3. Input PLC D110-117 to display
Example showing the value of the "p" character
1.Use the following software to select "共阴"
2.P brightness segment in the display box
3.the value 73 can display the P character
FAQ