MIMS cable Mineral insulated metal sheath cable

Sales MIMS cable Mineral insulated metal sheath cable

SICC is the first pioneering companies to manufacture MIMS(Mineral insulated metal sheath) cable to improve product performance and reliability. Over the decades, we’ve refined and improved that technology,as it remains the heart of our products to this day.

We specialise in:

•Mineral insulated thermocouple cable

• Mineral insulated RTD cable

• Mineral insulated heating cable

• Mineral insulated copper cable

Product Detail  


SPECIFICATIONS DETAILS

SICC can supply mi thermocouple cable type K/J/N/E/T from O.D=0.25 to 12.7 mm or 0.01" to 0.5" with SS,Inconel,Nircobell sheath.

SHEATH MATERIALS

 

SS304/321

SS316

SS310

INCONEL600

NIRCOBELL

DIA(mm/inch)

Simplex

Duplex

Simplex

Duplex

Simplex

Duplex

Simplex

Duplex

Simplex

Duplex

0.25/.010

 

 

 

 

 

 

0.5/.020

 

 

 

 

 

 

1.0/.040

 

 

 

 

 

 

1.5/.060

 

 

 

 

 

1.6/.062

 

 

 

 

 

2.0/.079

2.4/

3.0/.120

3.2/.125

4.0/

4.5/.177

4.8/.188

5.0/

6.0/.236

6.4/.250

8.0/.313

9.5/.375

10/

SICC can supply all kinds of mineral insulated RTD cable, including 3,4,6,8 cores, Nickel and Copper conductors.

SHEATH MATERIALS

 

SS304/321(NI)

SS316(NI)

SS304/321(CU)

SS316(CU)

DIA(mm/inch)

3

4

6

3

4

6

3

4

6

3

4

6

2/.079

2.4

3/.120

3.2

4

4.5/.177

4.8

5

6.0/.236

6.4/.250

8.0/.313

QUALITY GUARANTEE

All SICC’ MIMS cables are manufactured to meet the requirements specified in IEC61515 and ASTM E585, and the calibration tolerance of IEC584 and ASTM E230. We provide calibration results for all mineral insulated cable with each shipment, including EMF values, accuracy, batch number, raw materials chemistry, lab environment condition,etc, each order has only one job no for tracement. Calibration capability is available up to 1000C on suitable thermocouple types.

Our lab routinely calibrates at the following fixed points:100C,200C,400C,600C,800C,1000C,we works continuously to reduce the measurement uncertainty at each calibration temperature and new estimates are made every six months to ten months,ensuring any deviations are identified early so that results generated by the lab remain consistent and accurate.

Pls contact us for a completed quote and we will be waiting here at 7*24.