Medium Voltage filter capacitor (FC) banks are widely used to limit harmonic propagation, to improve power quality, to reduce harmonic distortion, and to provide reactive power compensation. These are designed for high‐current and high‐voltage applications. Many such filters are in operation for HVDC transmission systems, large industrial drives, static VAR compensators, and so on.
Filter Capacitor (FC) Banks
It is the most common method for the cancellation of harmonic current in the distribution system. Filter capacitor banks(FC) are basically designed on principle of either single tuned or band pass filter technology. As the name suggests shunt type filter are connected in system parallel with load. Passive filter offer a very low impedance in the network at the tuned frequency to divert all the related current & at given tuned frequency. Because of passive filter always have tendency of offering some reactive power in the circuit so the design of passive shunt filter take place for the two purpose one is the filtering purpose & another one is to provide reactive compensation purpose of correcting power factor in the circuit at desired level. The advantage with the passive shunt type filter is that it only carry fraction of current so the whole system AC power losses are reduced compare to series type filter. The given figure shows the schematic diagram of 6 pulse converter system connected with shunt passive type filter which are simply employed ever connection in distribution system have R-L load in system.
CHARACTERISTICS OF FC WITH FIXED ELEMENTS
Filter capacitor FC banks or passive filters were preferred in the earlier days for harmonic compensation because they are simple in structure and easy to install Different topologies of passive filters were emerged during stages of research. They are generally classified into series and shunt passive filters. Series passive filters use high series impedance to block harmonics, and shunt filters divert harmonics by means of a low impedance shunt path. The series filters must be designed to carry full load current, whereas shunt filters carry only a fraction of the current that a series filter carries. Also shunt filters, if properly designed, supply reactive power to the load at the fundamental frequency. Hence the most practical approach is to use shunt passive filters. The shunt passive filter is made up of passive elements resistance, inductance and capacitance. When the inductive and capacitive reactance of the passive filter become equal at a particular harmonic frequency, shunt passive filter acts as low impedance path for that harmonic component.
SPECIFICATION
Models
ZD-GWJ-PF-
Voltage
3-35 kV
Power
100Kvar~1200Kvar
Fundamental frequency
50 or 60 Hz
Tuning frequency
Optional
Installation
Indoor or outdoor
Capacitors
Film Capacitor banks
Reactor
Air or iron core
MV FC filter Capacitor banks Capacitors and Reactors
ADVANTAGES OF FC
A “clean” network creates much less strain on equipment and lengthens its life span. This results in a lower maintenance cost and the cost for replacing worn-out equipment. ZDDQ passive harmonic filters are the ideal solution to render medium/high-voltage networks more efficient and trouble-free.
APPLICATIONS
Nonlinear loads such as saturated coils and transformers are the main cause of producing harmonics in power system. Power electronic creates most of the due to its non liner characteristics pollution issues. Most of the pollution issues are created due to the nonlinear characteristics and fast switching of Power electronics.
Classically, shunt Filter capacitors FC or passive harmonic filters, mainly consist of tuned LC filters and or high passive filters are used to reduce the harmonics and power capacitors are used to improve the power factor. But they have the limitations of fixed compensation, large size and can also exile resonance conditions. In this work both shunt passive filter is used for power quality improvement. Transformers, motors, cables, interrupters and capacitors are the some equipment which is affected by harmonics converters mainly produces notches and they basically affect the electronic control devices.
There are two routes to the reduction of power quality problems. The first way is known as load conditioning, which assures that the equipment is made less sensitive and effective to power disturbances. The second technique is, to install line-conditioning systems that counteract or suppress the power system disturbances .In distribution systems passive filters have been used to limit of harmonic currents.
|
|
|
|
|
|
|
|