Ki-67 Antibody Reagent for Immunohistochemistry

Sales Ki-67 Antibody Reagent for Immunohistochemistry

IHC Antibody -- Ki-67


  • Specification/ml : 1、3、6、0.2(Concentrated)
  • Secondary Antibody : iVision™
  • Application : IHC-P
  • Positive Control : Tonsil
  • Cellular Localization : Nucleus

Product Detail  

Product name

IHC Antibody -- Ki-67


Packing specification

Code

Clone

Specifications

AM0146

K-2

0.1ml, 0.2ml, 1ml, 1.5ml, 3ml, 6ml, 11ml, 30ml

AM0241

MIB1

0.1ml, 0.2ml, 1ml, 1.5ml, 3ml, 6ml, 11ml, 30ml

AM0383

7B11

0.1ml, 0.2ml, 1ml, 1.5ml, 3ml, 6ml, 11ml, 30ml

AR0248

SP6

0.1ml, 0.2ml, 1ml, 1.5ml, 3ml, 6ml, 11ml, 30ml

AR0383

EPR3611

0.1ml, 0.2ml, 1ml, 1.5ml, 3ml, 6ml, 11ml, 30ml


Intended use

For Research use only. Ki-67 Antibody reagent is intended for use to qualitatively identify Ki-67 by microscopy in sections of FFPE tissue using immunohistochemical detection system.


Principle

Ki-67 antigen is a nuclear, non-histone protein that is present in all stages of the cell cycle except G0. Ki-67’s presence during cellular division makes it an excellent target for labeling rapidly growing malignancies. Given that its presence correlates with cell proliferation, the immunohistochemical labeling of Ki-67 antigen may be useful in characterizing a lesion’s growth fraction. Add the primary antibody to bind the antigen on tissue sections, and then use HRP labeled secondary antibody binding primary antibody to form the secondary antibody-primary antibody-antigen complex. When DAB chromogenic solution is added, HRP reacts with enzyme substrate to produce brown insoluble reaction product, which indirectly indicating the existence of antigen.



Main components

Immunoglobulin, antibody diluent


Storage

Store at 2~8℃ for 18 months


Sample requirements

FFPE tissues are usually cut into sections as thin as 35μm with a microtome. These sections are then mounted onto glass slides that are coated with a tissue adhesive.


Protocol

1. Sample preparationDeparaffinize the slides in xylene , , Ⅲ for 5 minutesTransfer the slides once through 100%, 100%, 95%, 75% alcohols for 2 minutes respectively. Rinse slides with deionized water for 30 seconds.

2BlockingBlock endogenous peroxidase activity by incubating sections in 3% H2O2 solution at room temperature for 5 minutes to block endogenous peroxidase activity. Rinse the slides with deionized water for 30 seconds.

3Antigen retrievalHeat the EDTA Antigen retrieval buffer to 100. Then place the slides in the boiled buffer and continue to heat for 1520 min. Naturally cool down for 30 minutes. Rinse the sample with wash buffer.

4Primary antibody incubation: Drain the slides. Add primary antibody to tissue, incubate at room temperature for 30 minutes. (use antibody diluent or PBS as control). Wash the slides in PBST for 2 times, 5 minutes for each time. If the Primary antibody is concentrated, please dilute it to RTU(ready to use) according to the information on packing. 

5. Secondary antibody: Drain the slides. Add secondary antibody to tissue and incubate at room temperature for 20 minutes. Wash the slides in PBST for 2 times, 5 minutes for each time.

6. DABDrain the slides. Add DAB to the tissue and incubate at room temperature for 5 min. Rinse slides with deionized water.

7. Hematoxylin stainingDrain the slides. Add Hematoxylin to the tissue and incubate at room temperature for 5 minutes. Rinse slides with water. Use the acid solution for differentiation. Rinse slides with water.

8. DehydrateDehydrate the slides in 75%, 95%, 100% alcohols for 2 minutes. Dry the slides. Cover stained tissue with a coverslip using mounting medium.


Positive localization

1. Positive localization: nuclear.

2. Positive control: tonsil.


Precautions

1. Please read the instruction carefully and become familiar with all components of the kit prior to use, Strictly follow the instruction during operation.

2. DO NOT use the kit or any kit component after their.

3. Only trained professionals can use this kit. Please wear suitable lab coat and disposable gloves while handling the reagents.

4. Avoid contact of skin, eyes and mucous membranes with the chemicals.

5. DO NOT pipet by mouth.

6. Unused reagents, used kit and waste must be disposed according to local regulations.


Manufacturer

Company Name: Xiamen Talent Biomedical Technology Co.,Ltd

Address: No.3rd and 4th Floors , Building B10, No. 2068 Wengjiao Road West, BioMedical Park, Haicang District, Xiamen City, 36100 China

Tel: +86 592 6315755            

E-mail: tlsw@talentbiomedical.com                

Website: www.talentbiomedical.com


Symbols


Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
X

Home

Supplier

Leave a message

Leave a message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.