♦Adopt double high-impedance three-electrode system, with online one-key calibration, real-time temperature compensation, electrode loose alarm, electrode good or bad alarm during calibration, and power-off protection (the calibration result and preset data will not be lost due to shut down or power failure).
♦Over-current protection, over voltage protection, high measurement accuracy, fast response, long life and so on.
♦Small in size, light in weight, easy to install and maintain, and the standard industrial signal output (0-5V, 0-10V, 4-20MA, Modbus RTU485) can meet the limit of on-site connection to various real-time monitoring equipment.
Water ORP Transmitter Detection Sensor
ORP transmitter adopt double high-impedance three-electrode system, with online one-key calibration, real-time temperature compensation, electrode loose alarm, electrode good or bad alarm during calibration, and power-off protection (the calibration result and preset data will not be lost due to shut down or power failure) , Over-current protection, over voltage protection, high measurement accuracy, fast response, long life and so on.
This product is suitable for: electroplating, yeast, food processing, sewage treatment, metallurgy, environmental protection and other occasions.
ltems | Parameters |
Measurement ORP range | -1000~1000mV or-2000~2000mV |
Measuring ORP Accuracy | ±3mV@-1000~1000mV ±6mV@-2000~2000mV |
ORP sensitivity | 1mV |
Power supply | DC 12V-24V |
Output | 0-5V/0-10V/4-20mA/RS485 |
load resistance | Voltage output: R load 2 10K Ω Current output: R loads(Uvcc-310.02Q |
Consumption | <1W |
Storage condition | 10-50℃(-20~+80°℃ peak) 20-60%RH |
Working environment | -20℃~+80℃ |
dimension | 65X46X28.5mm³ |
The linear relation between analog signals and the corresponding physical value:
0 to 5 v output:
(-1000~1000mV range):ORP=ORP output voltage*400-1000;
(-2000~2000mV range):ORP=ORP output voltage*800-2000;
0 to 10 v output:
(-1000~1000mV range):ORP=ORP output voltage*200-1000;
(-2000~2000mV range):ORP=ORP output voltage*400-2000;4-20 ma output:
(-1000~1000mV range):ORP=(ORP current-4)*125-1000;
(-2000~2000mV range):ORP=(ORP current-4)*250-1000;
Due to the ORP electrode in the measurement environment vulnerable to pollution cause electrode signal affected, in order to ensure the ORP sensor can normally use for a long time, usually need to make a correction on a regular basis through the calibration of transducer (once a month). Depending on the water samples of specific calibration cycle.