Water chiller machines CWFL-2000 for cooling 2000W fiber lasers

Sales Water chiller machines CWFL-2000 for cooling 2000W fiber lasers

CWFL-2000 water chiller developed by S&A Teyu is made especially for fiber laser applications up to 2KW. It features a dual channel design with control accuracy of ±0.5℃. Two temperatures can be supplied from one single chiller unit for the fiber laser and the laser head, indicating up to 50% space saving comparing with the two-chiller solution.
  • Package dimension : 74*61*104(L*W*H)
  • Dimension : 70*47*89(L*W*H)
  • G.W : 88.5Kgs
  • N.W : 78.5Kgs
  • Inlet and outlet : Rp1/2
  • Tank capacity : 15L
  • Pump power : 0.75KW/0.55KW
  • Reducer : capillary
  • Refrigerant : R-410a
  • Frequency : 50/60Hz
  • Voltage : 220V
  • Precision : ±0.5℃

Product Detail  

fiber laser chiller

CWFL-2000 water chiller developed by S&A Teyu is made especially for fiber laser applications up to 2KW. It features a dual channel design with control accuracy of ±0.5℃. 


Two temperatures can be supplied from one single chiller unit for the fiber laser and the laser head, indicating up to 50% space saving comparing with the two-chiller solution.


Fiber laser tends to generate a vast mount of heat during operation. Excessive heat will increase the risk of component failure or degrade the performance of the laser. With this active cooling laser water chiller machine, not only the fiber laser but also the laser head can be perfectly cooled and their lifespans can be extended. 

The warranty period is 2 years.


 Features  

1. Dual channel design for cooling fiber laser and the laser head, no need of a two-chiller solution;
2. ±0.5℃ precise temperature control;
3. Temperature control range: 5-35 ℃; 
4. Constant temperature and intelligent temperature control modes;
5. Built-in alarm functions to avoid water flow problem or temperature problem;
6. CE, RoHS, ISO and REACH compliant;
7. User-friendly temperature controllers for easy operation

8. Optional heater and water filter.



  Specification  

parameter

Note: 
1. The working current can be different under different working conditions; The above information is for reference only. Please subject to the actual delivered product;
2. Clean, pure, impurity free water should be used. The ideal one could be purified water, clean distilled water, deionised water, etc.;
3. Change out the water periodically (every 3 months is suggested or depending on the actual working environment);

4. Location of the chiller should be well ventilated environment. There must be at least 50cm from the obstacles to the air outlet which is on the top of the chiller and should leave at least 30cm between obstacles and the air inlets which are on the side casing of the chiller. 





  PRODUCT INTRODUCTION  


User-friendly temperature controllers for easy operation

temperature controller



Equipped with drain outlet with valve and universal wheels

water pressure gauge & drain outlet



Dual inlet and dual outlet port made of stainless steel to prevent potential corrosion or water leakage.

inlet & outlet


Water level check lets you know when it’s time to refill the tank.

water level gauge



Cooling fan of famous brand installed.

With high quality and low failure rate.
cooling fan


Alarm description

CWFL-2000 water chiller is designed with built-in alarm functions. 


E1- ultrahigh room temperature
E2 - ultrahigh water temperature
E3 - ultralow water temperature
E4 - room temperature sensor failure
E5 - water temperature sensor failure
E6 - external alarm input
E7 - water flow alarm input


  CHILLER APPLICATION  

 CHILLER APPLICATION




 WAREHOUSE  

18,000 square meters brand new industrial refrigeration system research center and production base. Strictly execute ISO production management system, using mass modularized standard production procedure, and standard parts rate up to 80% which is the source of stable quality. 


air cooled water chillers workshop


  TEST SYSTEM  
Excellent laboratory testing system simulates actual working environment for chiller. Overall performance testing before delivery: aging test and complete performance test must be performed on each finished chiller.

WATER CHILLER TEST SYSTEM