Spin Non-vaccum Histology Tissue Processor equipment

Sales Spin Non-vaccum Histology Tissue Processor equipment

YSD 260 automatic spin tissue processor and YSD 260-V automatic Vacuum spin tissue processor are equipment that perform tissue infiltration , through the combination of an efficient and well-tested technology

  • Size : Capacity :2.3L /1.3L

Product Detail  

Product Description

Spin Non-vaccum Histology Processor equipment

YSD-260 Non-vaccum Histology Tissue Processor equipment widely applied in pathologic laboratories , medical colleges and universities , animal and plan scientific research institute and food inspection department

The combination of a silent and robust and robust precision mechanism , plus new software , enable the user to attain the highest degree of felicity , as all function can be programmed

Non-vaccum Tissue Processor equipment

Product YSD-260 Non-vaccum Histology Tissue Processor equipment

Vacuum

NO

Temperature range

45℃ to 85℃

Tissue processing steps

12 steps

Number of reagent cups

9 (with a volume of 1.3L/2.3L for a larger volume)

Number of paraffin cups

3 (with a volume of 1L/1.8L for a larger volume)

Minimum time interval setting

1 min

Frequency of basket stirring

≥10 times/hour, 30 sec for each time

Program:Maximal turn-on dely
1 month
Program:Duration in each cup
0-10 hours(10 programs)
Size of basket
95mm*80mm
Voltage and frequency
AC 220V±10% 50Hz (standard model)
Power
500W (1.3L), 1000W (2.3L )
Net weight
60KG
Size
670(D)*540(H),680mm at the highest point

Histology Tissue processor machine Details

tissue processor machine

tissue processor

Tissue processor price specification:

  • Entire operation process is controlled by a PLC through a touch screen, easy to operate, reliable and stable.
  • Tissue specimen basket can be placed in a cup at any station by a mechanical arm, flexible and easy to operate.
  • Multiple safety protection mechanisms including power failure alert and operation error protection.
  • Stirring during the dehydration process ensures adequate contact of tissue with reagents and paraffin to improve dehydration performance.
  • Temperature of paraffin cup is precisely controlled by a constant temperature control system and the inner surface of the cup is TEFLON-coated, contamination-resistant, and corrosion-resistant.
  • 1.3L ( or a larger volume of 2.3L) medical glass beakers are used as processing cups, allowing clear observation of tissue changes during the operation.

tissue processor equipment

Histology tissue processor

tissue processor equipment

tissue processor

tissue processor equipment