Model: ZA5030A
Channel size: 500(L)*300(W)
Unit size: 1660(L)*746(W)*1165(H)
Unit weight: 284kg
Conveyor Max Load: 50kg
Penetration: 6mm steel
Power Consumption: max. 1KW
Generate direct: from bottom to top
Operation Power: 220VAC(±10%) 50±3Hz
Film Safety: Guarantee ASA/ISO1600 Film
Single Energy X Ray Inspection System Baggage Scanner ZA5030A
ZA5030A X-ray inspection system increases the operator’s ability to identify potential threats; the device is designed to scan briefcases, carry on baggage, small cargo parcels.
Product highlights
* Multilingual operation
* Automatic built in test and self diagnosis
* Secure access Key
* Uninterruptable power supply (UPS)
* Threat alert and material classification
* Auto archiving
* Network-Ready
* Energy saving design
* One key turn off
* Drugs and explosives inspection
* Indication of the date and time
* baggage counter
Physical Specifications | |
Unit weight (kgs) | 284 |
Unit size (mm) | 1660(L)*746(W)*1165(H) |
after packed in wooden pallet - |
|
Gross weight (kgs) | 400 |
Packing size | 180*88*138cm |
General Specifications | |
Tunnel size(mm) | 500(L)*300(W) |
Conveyor Speed(m/s) | 0.2 |
Conveyor height(mm) | 663 |
Conveyor Max Load(kgs) | 50 |
X ray dose per each inspection | 3.0 μGy |
X ray leakage | <1.0 μGy / h |
Penetration | 6mm steel |
Wire Resolution | dia 0.0787mm copper wire (AWG40) |
Penetration Resolution | dia 0.202mm copper wire (AWG32) under three-step aluminum wedge 9.5mm, 15.9mm, 22.2mm |
Spatial resolution: | Horizontal:dia1.0mm,Vertical: dia1.0mm |
Power Consumption | max. 1KW |
Noise | 56.3 dB |
Film Safety | Guarantee ASA/ISO1600 Film |
X-ray Generator (single) | |
Anode Voltage | 80 kv |
Anode power | 0.4-1.2mA (adjustable) |
Generate angle | 80 degree upward |
Generate direct | from bottom to top |
Cooling / Duty Cycle | Oil Cooling /100% |
Image System | |
X-ray Sensor | L-Shaped Photodiode Array (multi-energetic) , 12bit Deep |
Image Display | High resolution of 1024 * 1280 pixel; Image Grey Level: 4096 |
Image Enhancement | 1-64times enlargement continuity, Color/BW, negative, high/low |
penetration, organic /inorganic Stripping, general enhancement, and pseudo color, etc. | |
Image Recall | All preceding images recallable, retrieval |
Explosives & Narcotics Detection | Explosives & narcotics alarm and highlight according to atomic number signature |
High Density Region Alarm | Impenetrable region alarm and highlight, for possible concealing of threats and contrabands |
Threat Image Projection | Inserting fictional, but realistic images of threat items into baggage during screening operation, for maintenance of vigilance, as well as training and assessment of image identification capability |
Image Archive | Up to 100,000 images stored automatically, enable transferring to USB disk, and converting to JPG, BMP and other general formats |
Miscellaneous Functions | Time/date display, counters, user management, system-on/X-ray-on timers, power on self test, built-in diagnostic facilities, system log, system standby and stimulant training, ADS etc. |
Network Applications | Multiple remote applications available based on Ethernet LAN and windows platform, such as image centralized storage and identify, recheck workstation, and network TIP, etc ( Optional) . |
Images process | 24bit real time processing ,4colors analysis, Images displayed marked date and ID NO ,Count the number of bags |
Operating Environment | |
Operation temperature/Humidity | 0℃-45℃ / 5%-95%(non-condensing) |
Storage Temperature/Humidity | -40℃to 70℃ / 5%-95%(non-condensing) |
Operation Power | 220VAC(±10%) 50±3Hz (Optional: 100VAC,110VAC,120VAC,200VAC) |
UPS | 15mins, 30mins, 60mins etc, optional |
Computer and other | |
Monitor | High Resolution Color, LCD Accord, 17inch |
Hard Disk | SEAGATE 500G 3.5” |
CPU | G1610 2.6G |
Storage | 2GB 1600MHz DDR3 Innodisk |
Main board | H61 SYM76993VGGA |
Compliance | |
International | * ISO19001 ; ISO14001 ; OHSMS18001 ; |
* CE | |
* USA FDA | |
* Maximum X-ray leakage of less than 5 μSv/h(0.5mR/h) measured at 5cm from any external surface. (European standard - less than 1 μSv/h(0.1mR/h) measured at 10cm from any external surface) | |
National (China) | * Health Inspection Report |
* Computer Software Copyright Registration Certificate | |
* Software Product Registration Certificate | |
* Radiation Safety Certificate from Ministry of Public Security | |
* Quality Certification from Safety and Police Electronic Products Quality Inspection Center | |
* Design pantent certification: Patent No. : 201020700245.2 ; Patent No. : 201020700245.8 ; Patent No. : 201020700256.0 |