SCH-EM30 IP67 high protection level special frequency converter

Sales SCH-EM30 IP67 high protection level special frequency converter

♦ High-tech motor control concept, based on advanced DSP-technology V/Hz, SENSORLESS VECTOR, PMM synchronous motor mode - SPEED/TORQUE control Intelligent AUTOTUNING functions for easy set-up

♦  Rugged construction, all metal enclosure, thermally decoupled from motor, IP67/NEMA4, shock proof (4G)

♦  Flexible configurable man/machine interface - fieldbus capability

♦ Numerous functions, to make it suitable for all kind of industrial and residential applications, and for retrofit as well

♦  Smart PC-tools, for inverter control, parametrization and troubleshooting. Parameter-duplication stick

Product Detail  

SCH-EM30 IP67 high protection level special frequency converter

EM30 is developed for special enviornment, such as high humidity, powder, high viberation. It can work with induction motor and PM motor. The motor-mounted design is flexiable for all kind of motor.

Widely used in pump, gearbox, fan, conveyor, hay mower. etc

Technical parameters

Power
supply
Model Motor power
(kW)
Rated output
current  (A)
Input protection
current  (A)
1Ph

230V
EM30-0004S2 0.4 2.5 10.0
EM30-0007S2 0.75 4.5 18.1
EM30-0015S2 1.5 7 25.2
EM30-0022S2 2.2 10 32.0
3Ph

230V
EM30-0004T2 0.4 2.5 10.0
EM30-0007T2 0.75 4.5 17.0
EM30-0015T2 1.5 7 17.5
EM30-0022T2 2.2 10 25.0
EM30-0030T2 3.0 12 30.0
EM30-0040T2 4.0 17 42.5
EM30-0055T2 5.5 21 53.0
3Ph

400v
EM30-0007T3 0.75 2 6.5
EM30-0015T3 1.5 4 11
EM30-0022T3 2.2 6.5 15.0
EM30-0030T3 3.0 7.6 16
EM30-0040T3 4.0 9 21.0
EM30-0055T3 5.5 12 29.0
EM30-0075T3 7.5 17 34.0
EM30-0110T3 11 23 46.5

Technical Specifications

 

  Items Contents
Input Rated Voltage Range T3380V-480V(+10%/-15%);  S2/T2220V-240V(±15%)
Rated Frequency 50/60Hz
Output Rated Voltage Range 3-Phase:0-INPUT(V)
Frequency Range 0.50~590.0HZ(In Vector Control Mode:Max frequency is
not allowed to exceed 500.00Hz)
Contro
Mode
Control Mode Induction Motor:Sensorless Vector Control (SVC),V/F control
PMSM:open-loop vector control (SVC)
Carrier Frequency 08-16KHz;Fixed carrier-wave and random carrier-wave (F159)
Modulation Mode Space Vector PWM
Speed-control Scope Induction Motor-SVC 1:100;PMSM-SVC 1:20;
Steady Speed Precision ±0.5%(SVC)
Torque Resporse <20ms(SVC)
Torque Control Precision ±5%(SVC)
Start Torque 05Hz/100%(VVVF);0.5Hz/150%(SVC)
DC Braking DC braking frequency:0.20-50.00 Hz;
Braking time:0.00~30.00s;Braking current:0.0~100%
Operation
Function
Jogging Control Jogging frequency range:min frequency~max frequency,
Jogging acceleration/deceleration time:0.1~3000.0s
Frequency Setting mode Potentiometer or external analog signal(0~5V,0~10V,
0~20mA);Keypad (terminals)up/down key;External control
logic and self-circulation setting.
Main Frequency Source Digital given memory,external analogue All,Al2,input
pulse frequency given(100KHZ),digital given without
memory,PID,MODBUS
Auxiliary Frequency Source Flexible auxiliary frequency trim and the operate mode of main
and auxiliary frequency
Auto voltage regulation
(AVR)
When source voltage changes,the modulation rate can be
adjusted automatically,so that the output voltage is unchanged
Analog input 2-channel(All/AI2)
Analog outpu 2-channel (AOl/AO2)
Digit inpu 5-channel general-form input;
1-channel high-speed pulse inpu
Max frequency:100Khz,Internal impedance:3.3KQ;
Digit output l-channel DO1
Relay outpu 2-channel programmable relay output
Others Built-in PID adjusting,oscillation inhabitation,common DC
bus,auto carrier modulation,auto fast current-limiting,I/O
terminals self-checking function and OE automatic adjustment
Keypad 4-line LCD Support
Parameter copy Clone module supported
Protection
Function
Power supply under-voltage,phase loss,DC over-voltage,over-current,inverter overload,
motor overload,output phase loss,overheat,external disturbance,parameter measure failure
analog line disconnected protection,DC-GND short circuit,water shortage protection,
pressure protection,dormant state.
Envronmental
   Conftiors
Environment Temperature -10℃~+40℃
Environment Humidity Below 90%(no water-bead coagulation
Vibration Strength 4G
Height above sea level 1000m or below(Derating use when above 1000m)
Protection
    eve
IP66
Applicable
   Motor
0.4~11kW
Efficiency ≥93%
Others Cooling Mode Force-air cooling
Braking Unit Built-in braking unit needs external braking resistor
Fan Draught fan is pluggable.
Installation Mode Support installing with motor

Note:

1.When input voltage is higher than 420V,please contact with manufacture.

2.When network voltage is different,user can adjust braking voltage by function code.If users increase the initial voltage,then the value of braking resistor should be increased too.

 

Fig 1-2 Appearance and Structure

EM30 Appearance and Structure

Exquisite structure design of aluminum casting housing, detachable cover structureandconvenient connection can realize perfect combination with motor. Take EM30-0075T3J2for instance, the external appearance and structure are shown as belowin Fig1-3

 

Panel Illustration

The panel covers three sections: data display section, status indicating section and keypad operatingsection, as shown in Fig. 2-1.

EM30 Panel Illustration

FAQ

Can we accept samples customized?

No problem for samples order, and welcome your testing before your big order.

 

OEM and ODM are available?

Yes, we accept customized products

 

Can I get a lower price if I order large quantities?

Yes, Cheaper prices with bigger size orders, please contact us and we will give you a quatation.

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
X

Home

Supplier

Leave a message

Leave a message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.