Photocell And Daylight Harvesting Brightness Learning DC Motion Sensor
Features:
1. Photocell Function,daylight harvesting and ambient brightness learning
2. 12VDC input, 0-10V dimmable
3. Remote Control and five years warranty
4. Stand-by consumption less-than 20mA
Voltage
|
10.5-15V DC (Currect Required>30mA)
|
Dim Output
|
DIM 0-10V
|
Standby Consumption
|
<20mA (Power Consumption)
|
Daylight Harvesting
|
30Lux/50Lux/80Lux/120Lux/200Lux/250Lux/300Lux/350Lux/400Lux
|
Photocell
|
2Lux/10Lux(Light will be off when ambient brightness is 10 times of preset lux level)
|
Brightness Learning
|
Remote control to learn ambient brightness and daylight harvesting
|
Temperature
|
-20°C~+60°C
|
IP Grade
|
IP65
|
Warranty
|
5 Years
|
Photocell of DC sensor:
The sensor performs photocell function when preset lux level is only 2Lux/10Lux.
Light will be off when ambient brightness is 10 times of preset lux level
|
|
Light will automatically ON when ambient brightness is lower than perset level.
|
|
Light will automatically OFF when ambient brightness is 10 times higher than preset level.
|
Daylight Harvesting:
When ambient brightness is lower than the preset lux level options(30Lux/50Lux/80Lux/120Lux/
200Lux/250Lux/300Lux/350Lux/400Lux), LED light will be darker when ambient is getting brighter,
and brighter when darker; when ambient brightness is brighter than preset lux level, light off.
When daylight threshold set as 30Lux/50Lux/80Lux/120Lux/200Lux/250Lux/300Lux/350Lux/
400Lux, it performs daylight harvesting function.
Brightness Learning:
Instead of giving a specific lux level, this function enables current ambient brightness to be learnt and
set as a standard lux level; When ambient brightness is getting darker, the artificial light will be
brighter; and brighter darker; When ambient brightness exceeds the standard level, light will turn off.
How To Learn Ambient Brightness
1. Light ON, use HD05R remote;
2. Press “ Scene ” button;
3. Then press MW/PIR button twice till you see the MW icon and PIR icon on the screen display start
flashing, then the light will keep OFF for about 3S and turn ON again, that means learning completed.
Wiring diagram:
Installation:
Detection Coverage:
Typical installation height 8-12m.
This figure indicates the maximum distance at the highest mounting height with 100% sensitivity.