Customer Design |
|
Wide input voltage:16V~100V |
|
Bipolar (±10V) Analog DC signal input |
|
Max continuous input current 50A |
|
The product includes a current limiting circuit |
|
Work in the rated power without the need for external radiator |
Absolute Maximum Ratings |
Recommended working conditions |
Supply voltage +Vs:+120V Supply voltage +Vcc:16V Internal power loss:380W(Total power consumption of two tubes) Storage temperature:-55℃~105℃ Operating temperature(Tc):-40℃~85℃ Input voltage +PWM:±10V |
Supply voltage +Vs :16V~100V Supply voltage +Vcc:15V Input voltage +PWM:±2V
|
No. |
Symbol |
Function |
No. |
Symbol |
Function |
1 |
1 |
Control signal Ground |
8 |
A1 |
+100v |
2 |
2 |
+15V |
9 |
A2 |
Power ground |
3 |
3 |
NC |
10 |
A3 |
Output 1 |
4 |
4 |
Control signal |
11 |
A4 |
Output 2 |
5 |
5 |
+15V ground |
12 |
A5 |
Current protectthreshold |
6 |
6 |
Functiondetection signal terminal A |
13 |
A6 |
NC |
7 |
7 |
Functiondetection signal terminal B |
|
|
|