Industrial chiller for metal-cutting machinery

Sales Industrial chiller for metal-cutting machinery

S&A Teyu CWFL-2000 dual temperature water chiller machines with ±0.5℃ precise temperature control and multiple alarm functions are specially designed for cooling 2000W fiber lasers.
  • Dimension : 70*47*89(L*W*H)
  • G.W : 88.5Kgs
  • N.W : 78.5Kgs
  • Inlet and outlet : Rp1/2
  • Tank capacity : 15L
  • Pump power : 0.75KW/0.55KW
  • Reducer : capillary
  • Refrigerant : R-410a
  • Frequency : 50/60Hz
  • Voltage : 220V
  • Precision : ±0.5℃
  • Package dimension : 74*61*104(L*W*H)

Product Detail  

water chiller

S&A Teyu Industrial water chiller CWFL-2000 is developed and produced by S&A Teyu company. It is applied to cool metal-cutting machinery.


The CWFL series water chillers are so multi-functional that the laser device and the QBH connector/optics can be cooled by the low temperature control system and the high temperature control system respectively at the same time, which can greatly reduce the generation of the condensed water and save cost & space. 



  Laser water chiller machines features  
1. With environmental refrigerant;
2. ±0.5℃ precise temperature control;
3. The intelligent temperature controller has 2 control modes, applicable to different applied occasions; with various setting and display functions;
4. Dual temperature to satisfy different needs of fiber laser device and the optics;
5. With Ion adsorption filtrating and test functions conform to fiber laser device operating requirements;
6. Multiple alarm functions: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm;
7. Multiple power specifications; CE approval; RoHS approval; REACH approval;

8. Optional heater and water filter.

THE WARRANTY IS 2 YEARS AND THE PRODUCT IS UNDERWRITTEN BY INSURANCE COMPANY.


  2KW laser cooling machines specification  

parameter

Note: the working current can be different under different working conditions; The above information is for reference only. Please subject to the actual delivered product.


  PRODUCT INTRODUCTION  



Independent production of sheet metal, evaporator and condenser

Adopt IPG fiber laser for welding and cutting sheet metal. 


High precision temperature control system with dual temperature control function

Temperature control accuracy can reach ±0.5℃. High temp. for QBH connector/optics and low temp. for laser device.

Multiple alarm protection

The laser will stop working once it receives alarm signal from the water chiller for protection purpose.


temperature controller



Equipped with water pressure gauges ,drain outlet with valve and universal wheels.

Water pressure gauges help monitor the discharge pressure of water pump while universal wheels facilitate the moving of the chiller.

 

water pressure gauge & drain outlet


Dual inlet and dual outlet connector equipped.

Chiller inlet connects to laser outlet connector. Chiller outlet connects to laser inlet connector.

inlet & outlet


Level gauge equipped

water level gauge


Cooling fan of famous brand installed.

With high quality and low failure rate.
cooling fan


Customized dust gauze available and easy to take apart

 


  TEMPERATURE CONTROLLER PANEL DESCRIPTION  

S&A Teyu industrial water chillers are popular for its 2 temperature control modes as constant temperature and intelligent temperature control.Generally speaking, the defaulted setting for the temperature controller is intelligent temperature control mode. Under intelligent temperature control mode, the water temperature will adjust itself according to the ambient temperature. However, under constant temperature control mode, users can adjust the water temperature manually.

chiller temp controller


Suggestion:
Intelligent temperature control mode for QBH connector/optics
Constant temperature control mode for laser device


Temperature controller panel description:


  Alarm function  

(1)  Alarm Display:
E1 - ultrahigh room temperature
E2 - ultrahigh water temperature
E3 - ultralow water temperature
E4 - room temperature sensor failure
E5 - water temperature sensor failure
E6 - external alarm input
E7 - water flow alarm input

When alarm occurs, the error code and the temperature will be alternately displayed.
(2) To suspend the alarm:
In alarming state, the alarm sound could be suspended by pressing any button, but the alarm display remains until the alarm condition is eliminated.



  CHILLER APPLICATION  

 

fiber laser chiller application




  WAREHOUSE  
18,000 square meters brand new industrial refrigeration system research center and production base. Strictly execute ISO production management system, using mass modularized standard produces, and standard parts rate up to 80% which are the source of quality stability. 

air cooled water chillers workshop


  TEST SYSTEM  
With excellent laboratory testing system, simulates actual working environment for chiller. Overall performance testing before delivery: aging test and complete performance test must be executed on each finished chiller.

WATER CHILLER TEST SYSTEM