Widely motor input voltage range:16V~100V |
|
TTL square wave signal input |
|
Max Continuous output current : 30A |
|
Overheat Current-limiting protection function |
Absolute maximum rating |
Recommended operatingconditions |
Supply voltage +Vs:120V Supply voltage +Vcc:17V Control voltageV+PWM:7V Forbidden voltage VSI:7V Lead resistance welding temperature :300℃ Storage temperature(10s):-65℃~150℃ Junction temperature(Tc):150℃ |
Supply voltage+Vcc:15V±1V Supply voltage+Vs:16V~100V,typical value 60V Controlvoltage V+PWM:TTL width square wave(high level 5V) Operatingtemperature range,H class:-55℃~125℃
|
No |
Character |
Conditions -55℃≤Tc≤125℃ |
HSA03-B |
Symbol |
||
min |
Typical value |
max |
||||
1 |
Power +Vs |
- |
16 |
- |
100 |
V |
2 |
Power +Vcc |
- |
14 |
15 |
16 |
V |
3 |
+Vcc static current |
Io=0 |
- |
- |
80 |
mA |
4 |
Input clock high level |
- |
4.8 |
- |
5.3 |
V |
5 |
Input clock low level |
- |
0 |
- |
0.4 |
V |
6 |
clock input frequency |
- |
42 |
45 |
48 |
KHZ |
7 |
outputefficiency |
VS=100V,Output current 10A |
- |
97 |
- |
% |
8 |
Continuous working current |
Below 60℃ |
- |
- |
30 |
A |
9 |
Peak working current |
- |
- |
- |
40 |
A |
10 |
Ilimit/shutoff threshold |
- |
90 |
- |
110 |
mV |
11 |
Operating Temperature(shell temperature) |
- |
-55 |
- |
+125 |
℃ |
No |
symbol |
Designation |
No |
symbol |
Designation |
1 |
CLK IN |
Clockinput |
7 |
ISENSEB |
Load current inductor B
|
2 |
CLK Out |
Clockoutput |
8 |
Bout |
Output B |
3 |
+PWM |
TTL PWM square wave |
9 |
+Vs |
motor power |
4 |
Vref |
2.5V |
10 |
+Vcc |
+15V power |
5 |
GND |
Ground |
11 |
Aout |
OutputA |
6 |
VSHT |
Currentlimiter/ shut off |
12 |
ISenseA |
Load current inductor A |
Symbol |
Data/mm |
||
|
Min |
Typical |
Min |
A |
- |
- |
6.99 |
A1 |
2.28 |
- |
2.44 |
Φb |
1.47 |
- |
1.57 |
D |
- |
- |
40.40 |
E |
- |
- |
40.40 |
e |
- |
5.08 |
- |
e1 |
- |
30.48 |
- |
L |
11.43 |
- |
12.70 |
X1 |
49.56 |
- |
49.96 |
X |
- |
- |
58.90 |
ΦP |
3.80 |
- |
4.20 |