Horizontal Fluorine-Lined Industrial Hydrochloric Acid Pump

Sales Horizontal Fluorine-Lined Industrial Hydrochloric Acid Pump

FSB series horizontal fluorine-lined industrial hydrochloric acid pumps use a perfluorinated pump body design, which is suitable for use in environments with acid mist. It will not corrode the pump body, has a simple structure and is easy to use.

Product Detail  

Horizontal Fluorine-Lined Industrial Hydrochloric Acid Pump 

FSB pumps have the following design features:

  • The FSB series has two types: direct connection and shaft connection. The pump accessories of the two types are interchangeable and have strong compatibility.
  • The all-plastic shell design can withstand the corrosion of acid mist in the air.
  • Rear pull-out structure, easy maintenance.
  • No need to add oil, save worry and effort.
  • Can handle complex working media, excellent corrosion resistance, full plastic layer and silicon carbide friction parts.

 

FSB Series Fluorine Alloy Centrifugal Pumps Applications:

     Suitable for conveying hydrochloric acid of different concentrations at -20-110℃. Please consult our technical staff for specific selection.

 

Precautions For Use:

  • Plastic alloy pumps have lower steel strength than metal pumps, so the weight of the pipeline cannot be directly pressed on the pump body.
  • All joints must be kept sealed to prevent air leakage and liquid from affecting the working performance of the pump.
  • Before installation, the pump and motor should be checked, and all parts should be intact and there should be no debris in the pump.
  • Place the pump in a horizontal position, connect the inlet and outlet pipes and turn on the power. Finally, turn the coupling by hand to check for any collision.
  • The inlet and outlet pipelines should be supported by additional brackets, and pumps with high head should also be equipped with a check valve at the outlet to prevent water hammer damage caused by sudden shutdown.
  • If vibration or abnormal sound is found during operation, the pump should be stopped immediately to check the cause and the problem can be eliminated before working.

We can according to actual working condition, choose different configuration, provide an accurate solution. Technical consulting, please contact us!

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
X

Home

Supplier

Leave a message

Leave a message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.