FR-4 is also known as fiberglass board; FR4 reinforcing board; FR-4 epoxy resin board; flame retardant insulation board; epoxy board, FR4 light board; epoxy glass cloth board; circuit board drilling pad.
FR-4 Laminates Sheet Technical Date sheet
Item |
Test method |
Unit |
Typical Values |
|
Physical
Properties
|
Color |
Visual inspection |
-- |
Light/Green/Yellow |
Specific Gravity |
IEC 60893-2:2003 |
g/cm³ |
1.90-2.15 |
|
Water absorption |
ISO 62:2008 |
% |
<0.3 |
|
Electrical
Proerties
|
Electric strenght ┴ |
IEC 60893-2:2003 |
KV/mm |
≥14(3.0mm) |
Breakdown Voltage // |
IEC 60893-2:2003 |
KV |
≥60 |
|
Volume Resistivity |
IEC 60893-1980 |
Ω.m |
≥1.0*10¹² |
|
Surface Resistivity |
IEC 60893-1980 |
Ω |
≥1.0*1014 |
|
(1 MHZ)Dielectric constant |
IEC 60893-2:2003 |
-- |
4.0-5.5 |
|
(1 MHZ)Dissipation Factor |
IEC 60893-2:2003 |
-- |
0.04-0.05 |
|
Proof Tracking Index PTI |
IEC 60893-2:2003 |
V |
≥200 |
|
Insulation resistance after immersion 24Hrs in Water |
IEC 60893-2:2003 |
Ω |
≥5*1010 |
|
Mechanical
Properties
|
Flexural Strength ┴ |
IEC 60893-2:2003 |
Mpa |
≥340 |
Charpy Impact strength // |
IEC 60893-2:2003 |
KJ/m2 |
≥60 |
|
Tensile Strength |
IEC 60893-2:2003 |
MPa |
≥300 |
|
Bond Strength// |
IEC 60893-3-4:2003 |
N |
≥8000 |
|
Compressive Strength┴ |
IEC 60893-2:2003 |
MPa |
≥350 |
|
Flame
Resistance
Properties
|
Flame resistance |
IEC 60893-2:2003 |
-- |
V-0 |
Temperature Index |
IEC 60085:2004 |
°C |
155 |
|
Toxicant Content |
E662 |
-- |
Low |
|
Others |
Acetone Resistance |
boiled |
Min |
30(OK) |
More products series: