KEY FACTS AND BENEFITS
TECHNICAL DATA
Heating | |
Model | SC-L24M3C |
Gas type | NG |
Rated input capacity | 25.3Kw |
Rated output capacity(60/80℃) | 24Kw |
Rated Maximum output capacity(30/50℃) | 26.1Kw |
Minimum input capacity | 5.3Kw |
Minimum output capacity(60/80℃) | 4.8Kw |
Rated minimum output capacity (30/50℃) | 5.6Kw |
Heat efficiency (full load 60/80℃) | 95% |
Heat efficiency (full load 30/50℃) | 104% |
Heat efficiency (30% load 30/50℃) | 107% |
Heating system working pressure | 0.5~0.3MPa |
Maximum heating temperature | 90℃ |
Range of water temperature for radiator heating (±3℃) | 40℃~85℃ |
Range of water temperature for floor heating (±3℃) | 35℃~60℃ |
Rated electrical capacity | 125W |
Protection degree | I |
Water protection degree | IPX4D |
Expansion tank volume | 8L |
Expansion tank initial pressure | 0.1MPa |
Reference heating area | 60~200m2 |
Power supply | ~220V/50Hz |
Reference Natural Gas Cosumption | 0.36~2.52m3/h |
Net weight | 32Kg |
Net dimension (L*W*H) | 681*445*291mm |
Packing dimension(L*W*H) | 775*525*385mm |
Domestic Hot Water | |
Heat efficiency | 96% |
Maximum working pressure | 0.5Mpa |
Minimum working pressure | 0.03Mpa |
Rated hot water capability with △t=25k | 13.6L/min |
Rated hot water capability with △t=30k | 11.3L/min |
Range of water temperature for hot water (±3℃) | 35℃~60℃ |
Minimum hot water flow | 2.5L/min |
Water temperature stable flow | >6 L/min |
Limited flow | 10L/min |
Rated Gas Pressure | |
Natural Gas | 2000Pa |