Absolute maximum rating |
Operating conditions |
Input Voltage: 350V Output Power: 440W Storage temperature: -55~125℃ Lead welding temperature(10s): 300℃ Junction Temperature:<150℃ |
Input voltage: 220~320V Working temperature(Tc):-55~100℃ |
No. |
Character |
Symbol |
Conditions (Unless otherwisespecified(MI-270N-10-HT-N-M-F) ,-55℃≤Tc≤125℃,VIN=270V) |
Limit value |
Unit |
||||
min |
max |
||||||||
1 |
Input Transient voltagea/V |
Vis |
TA=25℃,Less 100ms |
200 |
350 |
V |
|||
2 |
Input under-voltage/V |
turn-on voltage |
VINL-ONT
VINL-OFF |
TA=25℃ |
185 |
195 |
V |
||
Turn-off voltage |
TA=25℃ |
170 |
179 |
V |
|||||
3 |
Output Voltage |
Vo |
Full-load |
TA=25℃ |
9.90 |
10.10 |
V |
||
Tc=-55℃ TC=100℃ |
9.75 |
10.25 |
|||||||
4 |
Output Current |
Io |
Vin=220V~320V |
- |
40 |
A |
|||
5 |
Voltage Regulation |
Sv |
220V 320V,Full-load TA=25℃、 Tc=-55℃ and TC=100℃ |
- |
±0.30 |
% |
|||
6 |
Load Regulation |
S1 |
No-load Full-load TA=25℃、 Tc=-55℃ and TC=100℃ |
- |
±0.30 |
% |
|||
7 |
Output voltage regulation range a |
VTR |
TA=25℃,Full-load |
-20 |
10 |
% |
|||
8 |
Output ripple voltage |
VPP |
BW≤20MHz, full-load, peak-peak
TA=25℃、 Tc=-55℃和 TC=100℃ |
- |
100 |
mV |
|||
9 |
Output over-voltage protection point |
VOVP |
TA=25℃,design guarantee |
11.25 |
13.75 |
V |
|||
10 |
Output current for over-current protection |
Iimax |
TA=25℃ |
43.2 |
52.8 |
A |
|||
11 |
Output load respond recovery voltage |
|
50%to100%to50% Iomax(0.1A/μs) TA=25℃ |
- |
6 |
%Vo |
|||
12 |
Output load respond recovery time |
|
50%to100%to50% Iomax(0.1A/μs) TA=25℃ |
- |
5 |
mS |
|||
13 |
Capacitive Load |
Co |
Full-load, TA=25℃ |
- |
4000 |
μF |
|||
14 |
Efficiency a |
η |
Vin=240V,Full-load or half-load, TA=25℃ |
91 |
- |
% |
|||
Vin=280V, Full-load or half-load, TA=25℃ |
91 |
- |
% |
||||||
Efficiency |
Vin=220V, Full-load or half-load, TA=25℃ |
89 |
- |
% |
|||||
Vin=320V, Full-load or half-load, TA=25℃ |
89 |
- |
% |
||||||
15 |
Output Voltage Temperature rate |
av |
Full-load |
- |
±0.04 |
%/℃ |
|||
16 |
Input reflect ripple voltage |
|
Full-load, TA=25℃, Peak-Peak |
- |
5 |
V |
|||
17 |
Isolation voltage |
Viso |
TA=25℃,10s,1mA Between input and output |
1500 |
- |
VDC |
|||
18 |
Isolation Resistance/MΩ |
Riso |
TA=25℃ 500vdc |
Between input ground and output ground |
100 |
- |
MΩ |
||
Between Input ground and Metal package |
100 |
- |
MΩ |
||||||
Between Output ground and Metal package |
100 |
- |
MΩ |
||||||
19 |
Over-heat protection |
TOTP |
Temperature of package |
100 |
110 |
℃ |
|||
20 |
Parallel power distributing precision |
PE |
Full-load, TA=25℃ |
- |
5 |
% |
|||
21 |
Parallel power distributing precision a |
|
Full-load, TC=-55℃, TC=100℃ |
- |
5 |
% |
|||
22 |
Parallel power distributing precision |
|
Half-load, TA=25℃ |
- |
8 |
% |
|||
23 |
Input supply ripple current a |
|
8-parallel, full-load, single output ripple current peak-peak, TA=25℃ |
- |
2 |
A |
|||
24 |
Input reflect ripple current a |
|
8-parallel, full-load, single input reflect ripple current peak-peak, TA=25℃ |
- |
800 |
mA |
|||
25 |
Output Overshoot Amplitude |
|
Full-load, TA=25℃
|
- |
1 |
% |
|||
26 |
Output Overshoot time |
|
Full-load, TA=25℃
|
- |
10 |
ms |
|||
a test only be needed when identified inspection or parameters are effected by changing process; b design guarantee, do not require test; c design guarantee, random testing 2pcs from final electric testing products, qualification inspection and quality consistency testing or testing for status change. |
characteristics |
conditions ( Unless otherwisespecified ,-55℃≤Tc≤125℃,VIN=270V±10V) |
criteria |
Parallel Capacity |
Full-load, TA=25℃ |
Max 8pcs |
Using function |
ON/OFF voltage is over 2.4V, TA=25℃ |
No output |
ON/OFF voltage is lower than 0.7V or hung in the air, TA=25℃ |
Normal Output |
No. |
characteristics |
Symbol |
Condition ( Unless otherwisespecified ,-55℃≤Tc≤125℃,VIN=270V) |
Limit value |
Unit |
||||
min |
max |
||||||||
1 |
Input Transient voltagea/V |
Vis |
TA=25℃,less 100ms |
200 |
350 |
V |
|||
2 |
Input under-voltage/V |
turn-on voltage |
VINL-ONT
VINL-OFF |
TA=25℃ |
185 |
195 |
V |
||
Turn-off voltage |
TA=25℃ |
173 |
183 |
V |
|||||
3 |
Output Voltage |
Vo |
Full-load |
TA=25℃ |
9.90 |
10.10 |
V |
||
Tc=-55℃ TC=100℃ |
9.75 |
10.25 |
|||||||
4 |
Output Current |
Io |
Vin=220V~320V |
- |
40 |
A |
|||
5 |
Voltage Regulation |
Sv |
220V 320V,Full-load TA=25℃、 Tc=-55℃和 TC=100℃ |
- |
±0.30 |
% |
|||
6 |
Load Regulation |
S1 |
No-load Full-load TA=25℃、 Tc=-55℃和 TC=100℃ |
- |
±0.30 |
% |
|||
7 |
Output voltage regulation range a |
VTR |
TA=25℃,Full-load |
-20 |
10 |
% |
|||
8 |
Output ripple voltage |
VPP |
BW≤20MHz, full-load, peak-peak TA=25℃、 Tc=-55℃和 TC=100℃ |
- |
520 |
mV |
|||
9 |
Output over-voltage protection point |
VOVP |
TA=25℃,design guarantee |
11.25 |
13.75 |
V |
|||
10 |
Output current for over-current protection |
Iimax |
TA=25℃ |
43.2 |
52.8 |
A |
|||
11 |
Output load respond recovery voltage |
|
50%to100%to50% Iomax(0.1A/μs) TA=25℃ |
- |
6 |
%Vo |
|||
12 |
Output load respond recovery time |
|
50%to100%to50% Iomax(0.1A/μs) TA=25℃ |
- |
5 |
mS |
|||
13 |
Capacitive Load |
Co |
Full Load, TA=25℃ |
- |
4000 |
μF |
|||
14 |
Efficiency a |
η |
Vin=240V, Full-load or half-load, TA=25℃ |
89 |
- |
% |
|||
Vin=280V, Full-load or half-load, TA=25℃ |
89 |
- |
% |
||||||
Efficiency |
Vin=220V, Full-load or half-load, TA=25℃ |
87 |
- |
% |
|||||
Vin=320V, Full-load or half-load, TA=25℃ |
87 |
- |
% |
||||||
15 |
Output Voltage Temperature rate |
av |
Full-load |
- |
±0.04 |
%/℃ |
|||
16 |
Input reflect ripple voltage |
|
Full-load, TA=25℃,peak-peak |
- |
5 |
V |
|||
17 |
Isolation voltage |
Viso |
TA=25℃,10s,1mA Between input and output |
1500 |
- |
VDC |
|||
18 |
Isolation Resistance/MΩ |
Riso |
TA=25℃ 500vdc |
Between input ground and output ground |
100 |
- |
MΩ |
||
Between Input ground and Metal package |
100 |
- |
MΩ |
||||||
Between Output ground and Metal package |
100 |
- |
MΩ |
||||||
19 |
Over-heat protection |
TOTP |
Temperature of package |
100 |
125 |
℃ |
|||
20 |
Parallel power distributing precision |
PE |
Full-load, TA=25℃ |
- |
5 |
% |
|||
21 |
Parallel power distributing precision a |
|
Full-load, TC=-55℃, TC=100℃ |
- |
5 |
% |
|||
22 |
Parallel power distributing precision |
|
Half-load, TA=25℃ |
- |
8 |
% |
|||
23 |
Input supply ripple current a |
|
8-parallel, full-load, single output ripple current peak-peak, TA=25℃ |
- |
2 |
A |
|||
24 |
Input reflect ripple current a |
|
8-parallel, full-load, single input reflect ripple current peak-peak, TA=25℃ |
- |
800 |
mA |
|||
25 |
Output Overshoot Amplitude |
|
Full-load, TA=25℃ |
- |
1 |
% |
|||
26 |
Output Overshoot time |
|
Full-load, TA=25℃ |
- |
10 |
ms |
|||
a test only be needed when identified inspection or parameters are effected by changing process; b design guarantee, do not require test; c design guarantee, random testing 2pcs from final electric testing products, qualification inspection and quality consistency testing or testing for status change. |
characteristics |
Conditions ( Unless otherwisespecified ,-55℃≤Tc≤125℃,VIN=270V±10V) |
criteria |
Parallel Capacity |
Full-load, TA=25℃ |
Max 8pcs |
Using function |
ON/OFF voltage is over 2.4V, TA=25℃ |
No output |
ON/OFF voltage is lower than 0.7V or hung in the air, TA=25℃ |
Normal Output |
No. |
characteristics |
symbol |
Conditions ( Unless otherwisespecified ,-55℃≤Tc≤125℃,VIN=270V) |
Limit value |
Unit |
||||
min |
max |
||||||||
1 |
Input Transient voltagea/V |
Vis |
TA=25℃,less 100ms |
200 |
350 |
V |
|||
2 |
Input under-voltage/V |
turn-on voltage |
VINL-ONT
VINL-OFF |
TA=25℃ |
185 |
195 |
V |
||
Turn-off voltage |
TA=25℃ |
170 |
179 |
V |
|||||
3 |
Output Voltage |
Vo |
Full-load |
TA=25℃ |
11.90 |
12.10 |
V |
||
Tc=-55℃ TC=100℃ |
11.75 |
12.25 |
|||||||
4 |
Output Current |
Io |
Vin=220V~320V |
- |
34 |
A |
|||
5 |
Voltage Regulation |
Sv |
220V 320V, Full-load TA=25℃、 Tc=-55℃和 TC=100℃ |
- |
±0.30 |
% |
|||
6 |
Load Regulation |
S1 |
No-load Full-load TA=25℃、 Tc=-55℃和 TC=100℃ |
- |
±0.30 |
% |
|||
7 |
Output voltage regulation range a |
VTR |
TA=25℃, Full-load |
-20 |
10 |
% |
|||
8 |
Output ripple voltage |
VPP |
BW≤20MHz, full-load, peak-peak
TA=25℃、 Tc=-55℃和 TC=100℃ |
- |
100 |
mV |
|||
9 |
Output over-voltage protection point |
VOVP |
TA=25℃,design guarantee |
13.25 |
15.75 |
V |
|||
10 |
Output current for over-current protection |
Iimax |
TA=25℃ |
36 |
44 |
A |
|||
11 |
Output load respond recovery voltage |
|
50%to100%to50% Iomax(0.1A/μs) TA=25℃ |
- |
6 |
%Vo |
|||
12 |
Output load respond recovery time |
|
50%to100%to50% Iomax(0.1A/μs) TA=25℃ |
- |
5 |
mS |
|||
13 |
Capacitive Load |
Co |
Full Load, TA=25℃ |
- |
4000 |
μF |
|||
14 |
Efficiency a |
η |
Vin=240V, Full-load or half-load, TA=25℃ |
92 |
- |
% |
|||
Vin=280V, Full-load or half-load, TA=25℃ |
92 |
- |
% |
||||||
Efficiency |
Vin=220V, Full-load or half-load, TA=25℃ |
91 |
- |
% |
|||||
Vin=320V, Full-load or half-load, TA=25℃ |
91 |
- |
% |
||||||
15 |
Output Voltage Temperature rate |
av |
Full-load |
- |
±0.04 |
%/℃ |
|||
16 |
Input reflect ripple voltage |
|
Full-load, TA=25℃,peak-peak |
- |
5 |
V |
|||
17 |
Isolation voltage |
Viso |
TA=25℃,10s,1mA Between input and output |
1500 |
- |
VDC |
|||
18 |
Isolation Resistance |
Riso |
TA=25℃ 500vdc |
Between input ground and output ground |
100 |
- |
MΩ |
||
Between Input ground and Metal package |
100 |
- |
MΩ |
||||||
Between Output ground and Metal package |
100 |
- |
MΩ |
||||||
19 |
Over-heat protection |
TOTP |
Temperature of package |
100 |
110 |
℃ |
|||
20 |
Parallel power distributing precision |
PE |
Full-load, TA=25℃ |
- |
5 |
% |
|||
21 |
Parallel power distributing precision a |
|
Full-load, TC=-55℃, TC=100℃ |
- |
5 |
% |
|||
22 |
Parallel power distributing precision |
|
Half-load, TA=25℃ |
- |
8 |
% |
|||
23 |
Input supply ripple current a |
|
8-parallel, full-load, single output ripple current peak-peak, TA=25℃ |
- |
2 |
A |
|||
24 |
Input reflect ripple current a |
|
8-parallel, full-load, single input reflect ripple current peak-peak, TA=25℃ |
- |
800 |
mA |
|||
25 |
Output Overshoot Amplitude |
|
Full-load, TA=25℃ |
- |
1 |
% |
|||
26 |
Output Overshoot time |
|
Full-load, TA=25℃ |
- |
10 |
ms |
|||
a test only be needed when identified inspection or parameters are effected by changing process; b design guarantee, do not require test; c design guarantee, random testing 2pcs from final electric testing products, qualification inspection and quality consistency testing or testing for status change. |
characteristics |
Conditions ( Unless otherwisespecified ,-55℃≤Tc≤125℃,VIN=270V±10V) |
criteria |
Parallel Capacity |
Full-load, TA=25℃ |
Max 8pcs |
Using function |
ON/OFF voltage is over 2.4V, TA=25℃ |
No output |
ON/OFF voltage is lower than 0.7V or hung in the air, TA=25℃ |
Normal Output |
No. | characteristics | Symbol | Conditions | Limit value | Unit | ||||
( Unless otherwise specified ,-55℃≤Tc≤125℃,VIN=270V) | Min | Max | |||||||
1 | Input Transient voltagea/V | Vis | TA=25℃,less 100ms | 200 | 350 | V | |||
2 | Input under-voltage/V | turn-on voltage | VINL-ONT | TA=25℃ | 185 | 195 | V | ||
VINL-OFF | TA=25℃ | 173 | 183 | V | |||||
Turn-off voltage | |||||||||
3 | Output Voltage | Vo | Full-load | TA=25℃ | 27.72 | 28.28 | V | ||
Tc=-55℃ | 27.6 | 28.4 | |||||||
TC=100℃ | |||||||||
4 | Output Current | Io | Vin=220V~320V | - | 14.5 | A | |||
5 | Voltage Regulation | Sv | 220V 320V, Full-load | - | ±0.30 | % | |||
TA=25℃、 Tc=-55℃和 TC=100℃ | |||||||||
6 | Load Regulation | S1 | No-load Full-load , | - | ±0.30 | % | |||
TA=25℃、 Tc=-55℃和 TC=100℃ | |||||||||
7 | Output voltage regulation range a | VTR | TA=25℃, Full-load | -20 | 10 | % | |||
8 | Output ripple voltage | VPP | BW≤20MHz, full-load, peak-peak | - | 460 | mV | |||
TA=25℃、 Tc=-55℃和 TC=100℃ | |||||||||
9 | Output over-voltage protection point | VOVP | TA=25 | 31.5 | 28.5 | V | |||
10 | Output current for over-current protection | Iimax | TA=25℃ | 16 | 20.3 | A | |||
11 | Output load respond recovery voltage | 50%to100%to50% Iomax(0.1A/μs) | - | 6 | %Vo | ||||
TA=25℃ | |||||||||
12 | Output load respond recovery time | 50%to100%to50% Iomax(0.1A/μs) | - | 5 | mS | ||||
TA=25℃ | |||||||||
13 | Capacitive Load | Co | Full-load, TA=25℃ | - | 4000 | μF | |||
14 | Efficiency a | η | Vin=240V,Full-load or Half Load, TA=25℃ | 89 | - | % | |||
Vin=280V, Full-load or Half Load , TA=25℃ | 89 | - | % | ||||||
Efficiency | Vin=220V, Full-load or Half Load , TA=25℃ | 87 | - | % | |||||
Vin=320V, Full-load or Half Load , TA=25℃ | 87 | - | % | ||||||
15 | Output Voltage Temperature rate | av | Full-load | - | ±0.04 | %/℃ | |||
16 | Input reflect ripple voltage | Full-load , TA=25℃,peak-peak | - | 5 | V | ||||
17 | Isolation voltage | Viso | TA=25℃,10s,1mA | 1500 | - | VDC | |||
Between input and output | |||||||||
18 | Isolation Resistance | Riso | TA=25℃ | Between input ground and output ground | 100 | - | MΩ | ||
500vdc | Between Input ground and Metal package | 100 | - | MΩ | |||||
Between Output ground and Metal package | 100 | - | MΩ | ||||||
19 | Over-heat protection | TOTP | Temperature of package | 100 | 125 | ℃ | |||
20 | Parallel power distributing precision | PE | Full-load, TA=25℃ | - | 5 | % | |||
21 | Parallel power distributing precision a | Full-load , TC=-55℃, TC=100℃ | - | 5 | % | ||||
22 | Parallel power distributing precision | Half-load, TA=25℃ |