GROWATT 25000~40000TL3-S 3 phase grid-tied inverter for commercial rooftop or ground mounted application. Integrated wire box for comprehensive protections.
GROWATT Solar Inverter Three Phase 25000~40000TL3-S for Commercial Application
* Maximum efficiency 99%
* Dual MPP trackers
* Supports export limitation
* Integrated DC switch
* String fuse and string monitoring
* Anti-PID function
* Type II DC and AC SPDs
Growatt 30000TL3-S ~ 50000TL3-S
|
||||
Datasheet
|
Growatt
30000TL3-S
|
Growatt
33000TL3-S
|
Growatt
40000TL3-NS
|
Growatt
50000TL3-S
|
Input Data
|
||||
Max recommended PV Power
(for module STC)
|
37500W
|
41250W
|
50000W
|
60000W
|
Max DC voltage
|
1000V
|
1000V
|
1000V
|
1000V
|
Start Voltage
|
250V
|
250V
|
250V
|
250V
|
PV voltage range
|
200V - 1000V
|
200V - 1000V
|
200V - 1000V
|
200V - 1000V
|
Nominal voltage
|
580V
|
580V
|
580V
|
695V
|
Full load MPP voltage range
|
450V - 800V
|
450V - 800V
|
540V - 800V
|
645V - 850V
|
Max. input current
|
34A/34A
|
38A / 38A
|
38A / 38A
|
38A / 38A
|
Max. input current per string
|
12A
|
12A
|
12A
|
12A
|
Number of MPP trackers / strings per MPP tracker
|
2/4
|
2/4
|
2/4
|
2/4
|
Output (AC)
|
||||
Rated AC output power
|
30kW
|
33kW
|
40kW
|
48kW
|
Max. AC apparent power
|
33.3kVA
|
36.6kVA
|
44.4kVA
|
53.3kVA
|
Max. output current
|
48.3A
|
53A
|
64.5A
|
64.5A
|
AC nominal voltage;range
|
230V/400V ; 320-478V
|
230V/400V ; 320-478V
|
230V/400V ; 320-478V
|
277V/480V ; 320-478V
|
AC grid frequency
|
50Hz/60Hz ±5Hz
|
50Hz/60Hz ±5Hz
|
50Hz/60Hz ±5Hz
|
50Hz/60Hz ±5Hz
|
Power factor
|
0.8 leading - 0.8 lagging
|
0.8 leading - 0.8 lagging
|
0.8 leading - 0.8 lagging
|
0.8 leading - 0.8 lagging
|
THDi
|
<3%
|
<3%
|
<3%
|
<3%
|
AC grid connection type
|
3W+N+PE
|
3W+N+PE
|
3W+N+PE
|
3W+N+PE/3W+PE
|
Efficiency
|
||||
Max.efficiency
|
98.9%
|
98.9%
|
99%
|
99%
|
Euro - eta
|
98.4%
|
98.4%
|
98.5%
|
98.5%
|
MPPT efficiency
|
99.5%
|
99.5%
|
99.5%
|
99.5%
|
Protection Devices
|
||||
DC reverse polarity protection
|
yes
|
yes
|
yes
|
yes
|
DC Switch
DC Surge protection Ground fault monitoring |
yes
Type II yes
|
yes
Type II yes
|
yes
Type II yes
|
yes
Type II yes
|
Output short circuit protection
|
yes
|
yes
|
yes
|
yes
|
AC Surge protection
String Fuse protection |
Type II yes
|
Type II yes
|
Type II yes
|
Type II yes
|
String fault monitoring
|
yes
|
yes
|
yes
|
yes
|
Anti-PID protection
|
yes
|
yes
|
yes
|
yes
|
General Data
|
||||
Dimensions (W / H / D)
|
470/754/270 mm
|
470/754/270 mm
|
470/754/270 mm
|
470/754/270 mm
|
Weight
|
48kg
|
48kg
|
48kg
|
48kg
|
Operating temperature range
|
-25 °C ... +60 °C
|
-25 °C ... +60 °C
|
-25 °C ... +60 °C
|
-25 °C ... +60 °C
|
Noise emission (typical)
|
≤40 dB(A)
|
≤40 dB(A)
|
≤40 dB(A)
|
≤40 dB(A)
|
Self-Consumption (night)
|
<1W
|
<1W
|
<1W
|
<1W
|
Topology
|
Transformerless
|
Transformerless
|
Transformerless
|
Transformerless
|
Cooling concept
|
Smart cooling
|
Smart cooling
|
Smart cooling
|
Smart cooling
|
Environmental Protection Rating
|
IP65
|
IP65
|
IP65
|
IP65
|
Altitude
Relative Humidity |
4000m
0~100%
|
4000m
0~100%
|
4000m
0~100%
|
4000m
0~100%
|
Features
|
||||
Display
|
Graphic LCD
|
Graphic LCD
|
Graphic LCD
|
Graphic LCD
|
Interfaces: RS232/R485/WiFi/LAN/GPRS
|
yes / yes / opt / opt / opt
|
yes / yes / opt / opt / opt
|
yes / yes / opt / opt / opt
|
yes / yes / opt / opt / opt
|
Warranty:5 years / 10 years
|
yes / opt
|
yes / opt
|
yes / opt
|
yes / opt
|
Certificates and Approvals
|
CE, IEC 62109-1/2, IEC 61727, IEC 62116, VDE 0126-1-1, Greece, VFR 2014, CEI 0-21, CEI 0-16, VDE-AR-N4105, EN50438, G59/3, AS
4777, PEA, IEC 60529, IEC 60068, IEC 61683, DRRG
|
Contact US:
General Manager
Name: Chris Zheng
Tel/WhatsApp/Wechat: 86-132-2596-3563
E-mail: sales1@eitaichina.cn
Address: #1002 NO.498 XingLinWan Road,JiMei District XiaMen China