Full Range C-reactive Protein (FR-CRP) Kit (Immunofluorescence)

Sales Full Range C-reactive Protein (FR-CRP) Kit (Immunofluorescence)

Full Range C-reactive Protein (FR-CRP) Kit (Immunofluorescence) is mainly for the in vitro quantitative determination of high sensitive C-reactive protein (hs-CRP) and conventional C-reactive protein in human whole blood (WB) and plasma.
  • Specification : 1/25 Tests

Product Detail  

Full Range C-reactive Protein (FR-CRP) Kit (Immunofluorescence) is mainly for the in vitro quantitative determination of high sensitive C-reactive protein (hs-CRP) and conventional C-reactive protein in human whole blood (WB) and plasma. C-reactive protein is an acute phase protein, which is very low in healthy people, and it increases dramatically when the body infection and tissue damage happen. C-reactive protein is a marker of inflammation and tissue damage, which is associated with the degree of infection, besides, it can also be used to detect conventional inflammation and cardiovascular inflammation and provide information for diagnosis, treatment and  monitor of inflammatory diseases.


Test principle

The assay is a double-antibody sandwich immunoassay for quantitative determination of CRP concentration based on immunofluorescence technology. Add the sample to the sample well of the cartridge. Through chromatography, the sample reacts with  the fluorescent latex particles coated with CRP monoclonal antibody Ⅰ on the conjugate pad. The complex spreads ahead along the nitrocellulose membrane captured by CRP monoclonal antibody Ⅱ on the test line. The more CRP the sample contains, the more complexes the test line accumulates. The intensity of fluorescent antibody signal reflects the amount of captured CRP. The immunofluorescence quantitative analyzer produced by our company can detect the concentration of CRP in the sample.


Package

25 Tests /Box


Materials provided

Contents


25

Cartridges

1

Calibration Card

25 FR-CRP sample diluent


One cartridge contains:

CRP monoclonal antibody

200-400ng

CRP monoclonal antibody

800±80ng

Goat-anti-mouse IgG antibody

800±80ng

Diluent:



Phosphate buffer (10mmol/L), Tween-20(1‰), etc. pH=7.4±0.2. Accessories required but not provided)

  • Immunofluorescence quantitative analyzer(NRM-FI-1000)
  • Reagent strip incubator
  • Pipette
  • CRP Control


Storage and stability

Sealed: The kit must be stored at 10-30℃, valid for 18 months. The sample diluent must be stored at 10-30℃, valid for 18 months.

Opened: The cartridge must be used within 1 hour once its foil pouch is opened. The sample diluent is valid for 1 month once it is opened.


Warnings and precautions

For in vitro diagnostic use.

The package insert must be carefully followed. Reliability of the test results cannot be guaranteed if there are any deviations from the package insert.


Safety precautions

CAUTION: This product requires the handling of human samples. It is recommended that all human sourced materials are considered potentially infectious and be handled in accordance with the OSHA Standard on Bloodborne Pathogens. Biosafety Level 211 or other appropriate biosafety practices should be used for materials that contain or are suspected of containing infectious agents.

Appropriate protective measures should be taken in the collection, processing, storage, mixing of the sample and testing process; once the sample and the reagent contact skin, wash with plenty of water; if skin irritation or rash occurs, get medical advice/attention.

Samples, used cartridge and disposable tips may be potentially infectious. Proper handling and disposal methods should be established by the laboratory in accordance with local regulations.


Handling precautions

Do not use the kit beyond the expiration date. The production date and expiration date are on the label.

Different batches of reagents, calibration cards and cartridges cannot be mixed.

The cartridge is disposable and cannot be reused.

Please do not use obviously damaged kit or cartridge.

Do not insert the cartridge wetted by other liquids into the analyzer, in order not to damage and pollute the instrument. Please avoid high temperature in the lab.

The calibration card and immunofluorescence quantitative analyzer should keep away from vibratile and electromagnetic environment when used. Slight vibration of the instrument is normal. Do not pull out the cartridge during testing.

To avoid contamination, wear clean gloves when operating with reagent kits and samples.

For a detailed discussion of handling precautions during system operation, refer to the NORMAN service information.


Specimen collection and preparation

The whole blood and plasma are advised to use EDTA anticoagulant tube, and the sample is advised to be tested immediately. If not, store the whole blood sample at 2-8℃, and complete the test within 24 hours. Plasma should be stored at 2-8℃; If testing is delayed more than 24 hours, then store the sample at -20℃ or below.

Heat inactivated and hemolysis samples should be abandoned.

The samples must reach room temperature (10-30℃) before the test. The cryopreserved sample can only be used after complete melting, rewarming and mixing. Avoid repeating freezing and thawing samples.


Procedure

Preparation

Installation of the immunofluorescence quantitative analyzer NRM-FI-1000and reagent strip incubator

Please read the operator’s manual of the immunofluorescence quantitative analyzer (NRM-FI-1000) and reagent strip incubator carefully before use.


Calibration Card installation

Each box contains a lot-specific Calibration Card to correct for lot-to-lot deviation.

Turn on the power switch, according to the system self-test prompt, waiting for the instrument to display the main interface.

Press “Assay Management”.

Insert the Calibration Card into the card slot following the direction of the arrow, then press “Read". Confirm the lot number of the Calibration Card with the reagent relevant information, then press "Ok".

Press “Return” to the main interface.


Cartridge

Cartridge needs to reach room temperature before opened.


Test procedure

Remove the cartridge (after reaching room temperature), draw in 10μL of whole blood or plasma to FR-CRP sample diluent. After gently mixing the sample, add 90μL of diluted whole blood or plasma into the sample well and incubate it for 5 minutes in the reagent strip incubator.

After incubation insert the cartridge into the immunofluorescence quantitative analyzer(NRM-FI-1000) using the cartridge arrows as a guide, and click start, then the instrument will scan the cartridge automatically.