♦Supply voltage: 24V DC, ambient temperature: +20°C, response time: 10ms, and analog output value ofmeasurement center distance are used for unspecified measurement conditions, The subiect is white ceramics
♦This is based on the FDA Standard, accordina to Laser Notice No, 50 of the FDA Standard.
♦This is the size in the measurement center distance. These values were defined by using 1/e2 (approx.13.5%) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point maybe higher than at
the point and this may affect the measurement value.
FSD22 series high-precision laser displacement sensor
SCH-FSD22 series switching analog measurement thickness high and low flatness sensor laser displacement distance sensor
Technical Specification
Type | Measurement center 100mm type | |
Part number | Analog+NPN output | FSD22-100P-UI |
Measurement center distance | 100mm | |
Measurement range | ±35mm | |
Beam diameter (Note 3) | Approx. ø120μm | |
Repeatability | 100μm | |
Linearity | ±0.3%F.S. | |
Temperature characteristic | 0.03%F.S./°C | |
Light source | Red semiconductor laser Class 2 [JIS / IEC / GB / FDA (Note 2)] Max. output: 1mW, Emission peak wavelength: 655nm | |
Supply voltage | 12 to 24V DC ±10%, Ripple P-P 10% or less | |
Power consumption | 40mA or less (at 24V DC supply voltage), 65mA or less (at 12V DC supply voltage) | |
Control output | Control output | PNP open-collector transistor |
•Maximum source current: 50mA | ||
•Applied voltage: 30V DC or less | ||
(Between control output to +V) | ||
•Residual voltage: 1.5V or less | ||
(At 50mA source current) | ||
•Leakage current: 0.1 mA or less | ||
Output operation | Switchable either Light-ON or Dark-ON | |
Short-circuit protection | Incorporated (Auto reset type) | |
Analog output | Analog voltage output | •Output range: 0 to +5V (at alarm: +5.2V) |
•Output impedance: 100Ω | ||
Analog current output | •Output range: 4 to 20mA (at alarm: 0mA) | |
•Load impedance: 300Ω or less | ||
Response time | Switchable between 1.5ms / 5ms / 10ms | |
PNP non-contact input | ||
•Input conditions | ||
Invalid: 0 to +0.6V DC or Open | ||
Valid: +4 to +V DC | ||
•Input impedance: Approx. 10kΩ | ||
Protection | IP67 (IEC) | |
Degree of pollution | 2 | |
Ambient temperature | -10 to +45°C (No dew condensation or icing allowed), Storage: -20 to +60°C | |
Ambient humidity | 35 to 85% RH, Storage: 35 to 85% RH | |
Ambient illuminance | Incandescent lamp: Acceptance surface illuminance 3,000ℓx or less | |
Operating altitude | 2,000m or less | |
Cable | 0.2mm2 5-core composite cable, 2m long | |
Material | Enclosure: Aluminum die-cast, Front cover: Acrylic | |
Weight | approx. 85g (including cable) | |
Applicable standard | EMC Directive Compliance, FDA Standard, UL Recognition |
Product Display
FAQ
Can I get some samples?
Yes, Sample order is available for quality check and market test. But you have to pay the express cost.
What's delivery time?
It usually takes about 3-5 working days for small order and 10-15 days for big order.
How to solve the quality problems after sales?
Take photos or videos of the problems and send to us.
We will make a satisfied solution for you within 24 hours after we confirm the problems.