East West dual tilt solar flat roof mounting system is a exclusive design, it can install more solar panel in the same area, and higher energy production output.
East West Dual Tilt Solar Ballast Mounting System for Flat Rooftop
Kseng`s East West dual tilt mounting system is a exclusive design, it can install more solar panel in the same area, and higher energy production output.Greater overall system power production under the same roof area.
. Cost Effectiveness, the same module qualities ( modules are quite cheap), East West dual tilt mounted on the flat rooftop can save on cost of energy. As solar system in an East-West solar racking are more packed together, potentially you would be saving some rails on the system. When you are installing a large project, bits and pieces adds up.
. Easier on the roof and Prevent winds blowing over
North-facing panels titled at 30° need heavy concrete ballasts or stronger mounting to prevent winds blowing the modules over, or off the roof. Less air resistance when using a East West system allows it to be installed on less structurally robust roofs and preserves roof loading capacity for other projects in the future.
Material: | Aluminum 6005-T5 & SUS 304 Stainless Steel |
Application: | Flat Rooftop |
Standard: | AS/NZS 1170 |
Wind Load: | 60M/S |
Snow Load: | 1.4KN/M2 |
Certification: | ISO9001/CE/UL |
Warranty: | 10 Years |
Service Life: | 25 Years |
Applicable Module: | Framed or Frameless |
Causion:
To avoid deadlock of stainless steel fastener, please avoid using electric tools for final tightening. And refer to the safe torque refined for stainless steel in the following forms. And: Do not fasten bolts tightly until each component is adjusted properly.
Bolt Dimension | Safe Torque(N*M) | Bolt Dimension | Safe Torque(N*M) |
M1 | 0.0193 | M2.5 | 0.356 |
M1.1 | 0.0272 | M3 | 0.634 |
M1.2 | 0.0369 | M3.5 | 0.997 |
M1.4 | 0.0578 | M4 | 1.48 |
M1.6 | 0.0853 | M4.5 | 2.14 |
M1.8 | 0.129 | M5 | 2.98 |
M2 | 0.174 | M6 | 5.07 |
M2.2 | 0.229 | M7 | 8.5 |
M8 | 12.3 | M10 | 24.4 |
M12 | 42.5 | M14 | 67.6 |
Components:
Installation Steps:
According to the panel array drawing, Locate the Pillars. Connect Pillars with M10*20 bolt and Guide Slider.
Construct triangle with angles and bolt M8*25.
Put Ballast Plate on Pillar 22, and fix triangle structure to the Pillar 22 with bolt M10*20.
Put on end clamp and mid clamp, not tightened.
Ballast with Concrete Block.
7.8. Install panel, tighten bolt of clamps.
Merit: