Multifunction Wireless High Voltage Phase Detector applied to phase detecting, phase testing, phase sequence judgement and electrictity testing of the high voltage line,metalclad withdraw switchgear and ring main unit and others occasion. 1. Model No.: ETCR1560 2. Phase Detection Mode: Normal phase detector & Remote phase detection 3. High Voltage Phase Detection Voltage : AC 10V~500kV 4. Ring Main Unit Phase Detection Voltage: AC 1V~600V 5. Metalclad Withdraw Switchgear Phase Detection Voltage : AC10KV ~35KV 6. Power Supply: Host: 3.7V, 2600mAh Rechargeable lithium battery; Detector: 3.7V, 600mAh Rechargeable lithium battery
Measurement of High/Low voltage AC current below 60kV. (Above 600V, operate with insulation rod). 1. Model No.: ETCR9220B 2. Current Range: AC 0.00mA~60.0A 3. Resolution: 0.01mA 4.CT Size: φ68mm 5. Line Voltage: Operate with insulation rods below 60kV current test 6. Power Supply: 6VDC (LR03 × 8pcs alkaline dry batteries)
Measurement of AC leakage current, phase, power energy, power, power factor, harmonicetc. Apply to oscilloscope, harmonic analyzer, power fault analyzer and other industrial control devices. 1:Range:0.00mA~60A AC 2:Turn Ratio:800:1 3:Resolution : 0.01mA 4:Accuracy Class : 0.5 5: Safety Class : CATⅢ600V 6: CT Size:Φ68mm
The milliohmmeter apply to measure the wire resistance of cables, the contact resistance of switches, connectors and relays, the DC resistance of coils, motors and transformers windings, and the connection resistance of the connecting conductor between the metal riveting, the metal components, the ground grid and the ground pole, etc. 1. Model No.: ETCR3620 2. Measurement Range:1mΩ~20.0kΩ 3. Detection Mode : AC/DC 2 channel simultaneous detection 4. Data Storage : 200 groups 5. Inspection Function : Yes 6. Power Supply : DC 7.4V 2600mAH rechargeable lithium battery
H/L voltage AC leakage current and current measurement below 60KV. (Above 600V operate with insulation rods). 1. Model No.: ETCR9100 2. Current Range: AC 0.00mA~600A 3. Resolution: 0.01mA 4.CT Size: φ33mm 5. Line Voltage: Below 60kV current test , operate with insulation rods 6. Power Supply: 6VDC (LR03 × 4pcs alkaline dry batteries)
After the operator wears the alarm, and close to the high voltage charged body for a certain distance, the alarm will send out a sound and light alarm according to the safety distance of the corresponding voltage level to remind the electrical worker to pay attention to safety and avoid high voltage electric shock accident. This product can also be used for line fault detection and electroscope. 1. Model : ETCR1870C 2. Alarm Voltage Range : 40V~1KV(Low voltage alarm) 3. Working Frequency : 50Hz/60Hz 4. Electricity Testing Mode : Non-contact mode 5. Detection Mode : Automatic trigger 6. Power Supply : CR1632(140mAH)button cell2PCS
Measurement of AC leakage current, current, higher harmonic current, phase, power energy, power factor. 1. Model No. : ETCR015 2. Range : 0.00mA ~ 100A 3. Clamp Size:17mm×18mm 4. Weight :175g 5. Safety Class : CATⅢ600V 6. Working Temperature : -15°C~50°C
Measurement of H/L voltage AC current below 110kV. (Above 600V, operate with insulation rod). 1. Model No.: ETCR9000 2. Current Range: AC 0mA~1200A 3. Resolution: 1mA 4.Data Storage: 99 Groups 5. Line Voltage: Below 110kV current test , operate with insulation rods 6. Power Supply: 6VDC (LR03 × 4pcs alkaline dry batteries)
Simultaneously monitor and record 1~3 channel of AC leakage currents, currents, and voltages. Used for the inspection of circuit insulation faults, monitoring of intermittent leakage faults, transformer core grounding current monitoring, cable grounding circulating current monitoring and other line current and voltage monitoring. 1. Model No.:ETCR8340 2. Current Range: AC 0.00mA~20A/60A/300A/600A/1000A/6000A(option) 3. Voltage Range: AC 0.0V~600V 4. Current Test Channel : 1~6 channel(option) 5. CT Caliber: Φ40mm/Φ60mm/64x16mm/Φ100mm(optional) 6. Power Supply: 6VDC~24VDC,50mA Max.(External power supply)
Simultaneously online monitoring and recording 1 ~ 3 channelAC leakage current and current, used for circuit insulation fault troubleshooting, monitoring intermittent leakage fault, check the happen time of insulation fault and maintenance lines, etc. 1. Model No.: ETCR8300F 2. CT Size: φ50mm~φ1500mm 3. Current Range : AC 0.00A~20.00kA 4. Resolution: AC 10mA 5. Current Clamps Quantity: 1 - 3PCS (optional); 6. Power Supply : Rechargeable lithium battery DC3.7V,2600mAh
Suitable for insulation resistance testing of cable, motor, generator, transformer, mutual inductor, high voltage switch, arrester and other large equipment.Insulation resistance measurement (IR); polarization index measurement (PI); absorption ratio (DAR); ramp test mode(RAMP) ; filtered resistance test (FR); Voltage measurement(V); current measurement(nA) 1.Model No.:ETCR3500B 2. Insulation Resistance Range: 0.5MΩ~5TΩ 3. Rated Voltage: 250v~10Kv(6 gears) 4. Shout Circuit Current: >5mA MAX 5. VoltageTest Range :AC/DC 0V~1000V 6. Power Supply : Rechargeable lithium battery pack 5.2Ah 14.8v
Measurement of H/L voltage AC current below 110kV. (Above 600V, operate with insulation rod). 1. Model No.: ETCR9000A 2. Measurement range: AC 0mA~1200A ; 3. Max resolution : 1mA; 4. CT Size: Ф48mm; 5. Communication mode: bluetooth, straight distance 10m ; 6. Power Supply : Ablelithium battery DC 7.4V 600mAH
Measurement of High/Low voltage AC current below 60kV. (Above 600V, operate with insulation rod). 1. Model No.: ETCR9220 2. Current Range: AC 0.00mA~60A 3. Resolution: 0.01mA 4.CT Size: φ68mm 5. Line Voltage: Bperate with insulation rods below 60kV current test 6. Power Supply: 6VDC (LR03 × 4pcs alkaline dry batteries)
Measurement of High/Low voltage AC current below 60kV. (Above 600V, operate with insulation rod). 1. Model No.: ETCR9200B 2. Current Range: AC 0mA~1200A 3. Resolution: 1mA 4.CT Size: φ68mm 5. Line Voltage: Below 60kV current test , operate with insulation rods 6. Power Supply: 6VDC (LR03 × 8pcs alkaline dry batteries)
Testing leakage operating time of various leakage protector. 1. Model No.: ETCR8600 2. Leakage Current Range : 15mA~500mA (10 gears) 3.Leakage Operating Time: 0ms~999ms 4. Line Voltage Measurement: Below 250V 5. Test Mode: Manual or Automatic 6. Power Supply: DC 6V LR03 1.5VX4PCS
Double Clamp Earth Resistance Tester applied with precise 4-pole, 3-pole and simple 2-pole method, selection method, double clamp method for grounding resistance measurement, The measurement of earth resistance, soil resistivity, earth voltage, AC voltage, grounding lead leakage current, AC current, DC resistance. 1. Model No.: ETCR3200 2. Erth resistance,Range:0.00Ω~30.00kΩ 3. Soil resistivity Range:0.00Ωm~9000kΩm 4. Test Frequency: 128Hz/111Hz/105Hz/94Hz(AFC) 5. Short-circuit Current:AC 20mA max 6. Power Supply:DC 9V (Alkaline dry battery LR14-1.5V )
Measurement ofAC/DC Current, AC/DC voltage, resistance, capacitance, continuity test, diode forward voltage drop andLED working voltage parameters etc. 1. Model No. : ETCR6470 2. DC Voltage : 2V/20V/200V/2000V 3. AC Voltage : 2V/20V/200V/2000V 4. DC Current : 20A/200A/2000A 5. Capacitance : 20uF/200uF/2uF/20uF/200uF/2000uF 6. Power Supply : 6F22 9V(IEC6F22, NEDA1604, JIS006P)
H/L voltage AC leakage current and current measurement below 60KV. (Above 600V operate with insulation rods). 1. Model No.: ETCR9100B 2. Current Range: AC 0.00mA~600A 3. Resolution: 0.01mA 4.Communication Mode: Wireless, transmission distance 30M 5. Line Voltage: Current testing below 60kV, operate with insulation rods 6. Power Supply: 6VDC (LR03 × 8pcs alkaline dry batteries)
Apply to equipotential bonding resistance testing between metal components, the transformer windings DC impedance testing. Measurement of DC low value resistance, contact resistance, riveting resistance, wire length, etc. 1. Model No.: ETCR3700 2. Range: 0.0001Ω~30.00kΩ 3. Data Storage : 400 groups 4. MaxTest Current :≥2A 5. Detection Mode : Precision 4-wire method, 2 channel A/D simultaneous detection 6. Power Supply : DC 7.4V 2.6Ah, rechargeable lithium battery, full charge about 8.4V
Suitable for measuring the insulation resistance,dielectric absorption ratio andpolarization index of electric motor ,cable ,switch,electrical appliance and others electrical equipment and insulation materials. 1. Model No.: ETCR3480B 2. Insulation Resistance Tester:0.1MΩ~400GΩ 3. Voltage Range:AC/DC 0V~750V 4. Rated Voltage:5000V 5. Short Circuit Current:≥2mA MAX 6. Power Supply : DC 1.5V LR14 X 6PCS