Characters
-120V/240V Split phase, 220V Single phase Pure sine wave inverter.
- Self-consumption and Feed-in to the grid.
- Auto restart while AC is recovering.
- Programmable supply priority for Battery or Grid.
- Programmable multiple operation modes: On grid, off grid and UPS.
- Configurable battery charging current/voltage based on applications via LCD setting.
- Configurable AC/Solar Charger priority via LCD setting.
- Compatible to mains voltage or generator power.
- Overload/Over temperature/Short circuit protection.
- Smart battery charger design for optimized battery performance
- With limit function, prevent excess power overflow to the grid.
- Supporting wifi monitoring and Build-in 2 strings of MPP trackers
- Smart settable three stages MPPT charging for optimized battery performance
- Maximum 5.5KW charging capacity.
-Time Of Use setting with settable inverter maximum output power, allow user to use grid power more efficient and recover the investment.
-Parallel connection (for both on grid mode and off grid mode) is optional to increase the power.
Specification
Model |
8KW |
Battery Input Data |
|
Battery Type |
Lead-acid or Lithium-ion |
Battery Voltage Range (V) |
40~60V |
Max. Charging Current (A) |
190A |
Max. Discharging Current (A) |
190A |
Charging Curve |
3 Stages / Equalization |
External Temperature Sensor |
Optional |
Charging Strategy for Li-Ion Battery |
Self-adaption to BMS |
PV String Input Data |
|
Max. DC Input Power (W) |
10400W |
PV Input Voltage (V) |
370V (100V~500V) |
MPPT Range (V) |
125V-425V |
Start-up Voltage (V) |
150V |
PV Input Current (A) |
22A+22A |
No.of MPPT Trackers |
2 |
No.of Strings Per MPPT Tracker |
2+2 |
AC Output Data |
|
Rated AC Output and UPS Power (W) |
8000W |
Max. AC Output Power (W) |
8800W |
Peak Power (off grid) |
2 times of rated power, 10 S |
AC Output Rated Current (A) |
35A |
Max. AC Current (A) |
38.5A |
Max. Continuous AC Passthrough (A) |
50A |
Output Frequency and Voltage |
50 / 60Hz; 230Vac (single phase) or 120V/240V split phase |
Grid Type |
Single Phase |
Current Harmonic Distortion |
THD<3% (Linear load<1.5%) |
Efficiency |
|
Max. Efficiency |
97.60% |
Euro Efficiency |
97.00% |
MPPT Efficiency |
99.90% |
Protection |
|
PV Input Lightning Protection |
Integrated |
Anti-islanding Protection |
Integrated |
PV String Input Reverse Polarity Protection |
Integrated |
Insulation Resistor Detection |
Integrated |
Residual Current Monitoring Unit |
Integrated |
Output Over Current Protection |
Integrated |
Output Shorted Protection |
Integrated |
Output Over Voltage Protection |
Integrated |
Surge protection |
DC Type II / AC Type II |
Certifications and Standards |
|
Grid Regulation |
VDE 0126, AS4777, NRS2017, G98, G99, IEC61683, IEC62116, IEC61727 |
Safety Regulation |
IEC62109-1, IEC62109-2 |
EMC |
EN61000-6-1, EN61000-6-3, FCC 15 class B |
General Data |
|
Operating Temperature Range (℃) |
-25~60℃, >45℃ Derating |
Cooling |
Smart cooling |
Noise (dB) |
<30 dB |
Communication with BMS |
RS485; CAN |
Weight (kg) |
32 |
Size (mm) |
420W×670H×233D |
Protection Degree |
IP65 |
Installation Style |
Wall-mounted |
Warranty |
5 years |