Detached Design Remote Control Apply for sterilizing lamp on/off function sensor
HD401S CR-UV Features:
1. When a person walks into the detection area,the lights will automatically go out.
2.The detection area,delay-off settings and delay-on settings are adjustable.
3. Support remote control to set parameters by HD01R.
4. Separate design for easy installation into lamps
5. Saving energy,protecting environment intelligent sterilization.
6. IP 20 with 5 years warranty.
HD401S CR-UV Description:
Operating voltage | 120VAC,50Hz/60Hz |
Switch capacity | Impedance load 400w,capacitive load 200w |
Stand-by power | ≤1W(230VAC) |
Power on delay turn on time | 15s |
Detection area | 50%/100% |
Hold time | 15min/30min/60min/120min |
Method of the connection wire | Amphenol connector(L,N,N,L') |
Output control | ON/OFF |
Method of setting up | By HD01R remote control |
Microwave Frequency | 5.8GHz±75MHz |
Microwave Power | <0.3mW |
Mounting Height | 0.5m-1.2m(on the desktop),1.5-3m(side mounting) |
Detection Range | Radius3-6m/9.84-19.68ft(Ceiling Mounted) |
Motion Detection | 0.5m/s |
Detection angle | Less than 150° for wall-mounted installation,the ceiling installation is 360° |
Temperature | -25°C~+60°C |
IP Grade | IP 20 |
Certificate | RoHS CE |
Warranty | 3 years |
Product net weight | 0.06kg |
manner of packing | Products with air bags, cardboard compartments packing, 18pcs/layer, 6 layers/box |
carton size | 40*30*24cm |
Gross weight | 7.5kg |
The detection distance and delay time setting reference HD01R remote control |
ON/OFF Control Detection Area Remote Control
Warranty 5 years Hold Time
HD401S CR-UV Mechanical Structure
HD401S CR-UV Dimensions (mm)
1.When the sterilization lamp is powered on,the indicator light will be on long.The sterilization lamp will be saved and turned off.The remote control (ON/OFF) is needed to turn on the light.
2.After pressing the remote control button(ON/OFF),the indicator light flashes for 15s.After 15s,the sterilization light starts to work.After the end of working hours,the sterilization light turns OFF.
3.If the sterilization lamp is in working state and someone is detected walking,the sterilization lamp will automatically turn OFF.After people leve the induction area,the sterilizing lamp will not automatically turn ON,so you need to press ON/OFF button remote control to turn ON the lamp again.
When the sterilizing light is After 15s,the sterilizing lamp If the sterilizing lamp is working
ON,turn ON he light by will start to work.The time can state and someone is detected
remote control(press ON/OFF) be set to(15min/30min/60min to be walking,the light will
and the indicator flashes for /120min).After the working automatically turn off,and the
15s,When the sterilizing light time,the lamp will automatically rear light will not automatically
is ON,people should leave turn off. turn on when the person leaves
the scene. the sensing area.
Remark:
There are two ways turn on the sterilization lamp
1.Press the remote control(ON/OFF)key,the indicator light flashes for 15s,and the sterilizing light turns ON.
2.Press AC switch 3-8 times continuously,and turn on the sterilizing lamp after the indicator flashes for 15s.
HD01R remote control instruction for use:
Remote Keying | Function Of The Button | Function Introduction | |
ON/OFF | 1. Sterilization lamp long on/long off function; | ||
2. Turn off the induction mode and press the reset key to exit. | |||
Reset | Restore factory default setting: detection range 100%, turn on lamp delay 15S, sterilization lamp delay 1H turn off lamp | ||
Detection area | Refers to the microwave detection range setting | ||
Hold time | That is, the working time of the disinfection lamp is long | ||
Note: In the absence of obstacles, the linear remote control distance is about 4-6m; The blank keys in the remote control are non-functional keys. |
|||
Remote control Settings:
1. Press the reset button in front of the sensor to be set;
2. Set the detection distance and working time of the sensor
3. Remote control setting is completed, and the set value sensor will be saved automatically.
Note: The indicator light will flash when the sensor receives the signal during setting, indicating that the setting is successful.