Our solar cable PV1-F is designed and produced by the standard of 2Pfg1169/08.2007,the max voltage can meet with 1.8KV(Core-to core,non-grounded system),the max environment temperature of working is 120 degree and can be used in multiple circuit by more wires.we can supply free sample to our overseas customers and customers must bear express cost by themself.
2PFG 1169 PV1-F 1*4MM2 solar cable
In a solar power system of rated voltage U0=0.6KV,PV cables are used to connect between solar panels and inverters.
Twin Core Solar Cable are widely used for electrical installation of indoor and outdoor solar installation equipment.
Product description:
Voltage Rating (Uo/U) |
AC:600/1000V DC: 1000V |
Test Voltage |
6500V AC |
Temperature Rating |
Rated: -40°C to +90°C Max.conductor temp: +120°C Short Circuit: +250°C |
Minimum Bending Radius |
Ø≤12mm 4 x overall diameter Ø>12mm 10 x overall diameter |
Testing Standard |
Flame Test : IEC60332-1-2 ,EN60332-1-2 Halogen Free : EN50627-2-1 , EN60684-2 |
|
|
Cable Name |
Cross Section
(mm²)
|
Construction
(No./mm)
|
Conductor
Stranded O.D.
(mm)
|
Conductor resistance
Max (Ώ/km)
|
Cable O.D.
(mm)
|
Max.DC Voltage
(V)
|
PV1-F Twin core TÜV 2PfG/1169 |
2*1.5 | 30/0.24 | 1.51 | 13.7 | 4*0.82 |
1000 |
2*2.5 | 49/0.24 | 1.93 | 8.21 | 4.4*9.0 | ||
2*4.0 | 52/0.3 | 2.46 | 5.09 | 4.6*9.4 | ||
2*6.0 | 78/0.3 | 3.06 | 3.39 | 5.3*10.9 | ||
2*10 | 77/0.4 | 4.05 | 1.95 | 7.1*14.5 | ||
2*16 | 126/0.4 | 5.6 | 1.24 | 10.2*20.7 | ||
2*25 | 196/0.4 | 7 | 0.795 | 12.2*24.7 | ||
2*35 | 276/0.4 | 8.3 | 0.565 | 13.8*27.9 |
Application:
The advantage of Solar power station: Safety in Use, Pollution-free, Noise-free,High quality power energy, no limit for the resource distribution area, no waste of fuel and Short-term construction.
Solar power is becoming the most popular and promoted energy all over the world.
***Large photovoltaic power generation
***Rural building photovoltaic (PV)power generation
***City street light photovoltaic (PV)power generation
***Urban road lamp power
***Large photovoltaic power generation in public places
***Photovoltaic industrial building
Application Techniuque Specification
Double insulation,electron-beam cross-linked cables for photovoltaic power station.
Construction:
①Conductor: Tined copper,according to the VDE 0295/EN 60228, Class 5
②Insulation: Polyolefin copolymer electron-beam cross-linked
③Outer sheath: Polyolefin copolymer electron-beam cross-linked.Sheath color: Black.
Material Properties /Standards
Fire performance: IEC 60332-1
Smoke emission: IEC 61034;EN 50268-2
Low fire load:DIN 51900
Approvals:EN 50618:2014, H1Z2Z2-K
Application standards:
EN 60811;EN60216;EN50395;EN50396.