1650nm FBG Reflector LC/APC
The fiber brag grating reflector(FBG Reflector) is a low-cost specific band reflector mounted on the optical network unit (ONU) side. It can reflect light pulses (1650 +/- 5 nm) from the OTDR on the fiber line terminal (OLT) side nearly 100%, while the working bands of the passive optical network (PON) are transmitted normally. The OTDR can determine whether the fiber line is normal by detecting the signal reflected by the fiber grating reflector. When the reflected signal is lower than the normal value, the line loss is too large; when the reflection value is 0, the optical fiber line is broken。Therefore, we can maintain the fiber line in time by the real-time monitoring of the fiber line.
Application
Detection and maintenance of Passive Optical Network lines (applied to FTTx).
Optical parameter
item |
parameter |
specification |
unit |
Remarks |
|
1 |
wavelength range |
Pass band |
1260~1625 |
nm |
- |
Reflect band |
1644.5~1655.5 |
nm |
- |
||
2 |
Pass band |
IL |
≤1.4 |
dB |
@1260~1360 |
≤1.4 |
dB |
@1460~1600 |
|||
≤3.4 |
dB |
@1600~1625 |
|||
ORL |
>35 |
dB |
@1260~1580 |
||
>30 |
dB |
@1580~1620 |
|||
>20 |
dB |
@1620~1625 |
|||
3 |
Reflect band |
IL |
>21 |
dB |
@1644.5~1655.5 |
ORL |
≤1.0 |
dB |
@1644.5~1655.5 |
||
4 |
PDL |
≤0.4 |
dB |
@1260~1600 |
|
5 |
Ripple |
≤0.6 |
dB |
@1644.5~1655.5 |
|
6 |
TDL |
≤0.5 |
dB |
@1260~1600 |
|
7 |
Max Optical Power Handling |
27 |
dBm |
- |
|
8 |
Plug Times |
>500 |
Times |
- |
|
9 |
Connector |
LC/APC |
- |
- |
Structure
The FBG reflector adopts a standard LC connector structure, and its external dimensions are as follows:
Working/storage conditions
parameter |
specification |
unit |
Working temperature |
-25 ~ +65 |
°C |
Working humidity |
5~95 |
%RH |
Storage temperature |
-40 ~ +85 |
°C |
Storage humidity |
5~95 |
%RH |