Sales Manager: Andrea
Email: Andrea@tmaxlaboratory.com
Wechat: 18250801164
High Temperature upto 1700C Muffle Box Furnace with Different Chamber Sizes Available
Detailed technical parameters
Model |
TMAX-1700 Muffle-I |
TMAX-1700 Muffle- II |
TMAX-1700Muffle- III |
TMAX-1700Muffle-Ⅳ |
TMAX-1700Muffle-Ⅴ |
TMAX-1700Muffle-ⅤI |
TMAX-1700Muffle-vI I |
Power |
2.5 KW |
3 KW |
5 KW |
7KW |
9 KW |
13KW |
24KW |
Chamber size(DXWXH) |
120X120 X120mm |
160X150 X150mm |
200X200 X200mm |
300X200 X200mm |
300X250 X250mm |
400X300 X300mm |
500X400 X400mm |
Outline Dimension |
470*480 *820 |
520X490 X880 |
564X530 X930 |
600X630 X970 |
620X630 X1020 |
670X760 X1450 |
840X870 X1740 |
Supply voltage |
220V |
220V |
220V |
220V |
380V |
380V |
380V |
Phase |
single phase |
||||||
Heating element |
1800TypeMoSi2 heating element |
||||||
Control mode |
UAV program temperature control instrument
1, 30-stage program temperature control intelligent PID adjustment. 2. With over-temperature protection, the electric furnace heating circuit is automatically cut off when the temperature is over-temperature or broken, (when the electric furnace temperature exceeds 1720 degrees or the thermocouple is blown, the AC relay on the main circuit will be automatically disconnected, the main circuit is broken. On, the ON light on the panel is off, the OFF light is on, and the limited protection electric furnace). 3, with 485 communication interface (standard when purchasing software) 4, with power-off protection function, that is, when the power is turned on after the power is turned off, the program does not start from the starting temperature, but the furnace temperature rises from the time of power failure. 5. The meter has the function of temperature self-tuning. |
||||||
Heating rate |
≤30℃/ Min |
||||||
Recommended rate |
15℃/ Min |
||||||
Chamber material |
Type 1800 alumina polycrystalline fiber (alumina content above 95%) |
||||||
Control precision |
+/- 1℃ |
||||||
max temperature |
1700℃ |
||||||
rated temperature |
1650℃ |
||||||
Peripheral surface temperature |
≤45℃ |
||||||
Thermocouple Type |
B |
||||||
Trigger |
Phase shift trigger (with soft start and current limit function) Current limiting function: No matter how to adjust the heating time, the secondary current of our electric furnace after passing through the transformer is limited to 160A, which has limited protection of the equipment, no matter how you operate, it will not burn out the equipment. Soft start function: the current will increase slowly when starting up, and the impact on the heating element is small, which is beneficial to the extension of the life of the heating element. |
||||||
electric appliance |
Zhejiang chint |
||||||
silicon controlled |
106/16E SEMIKRON |
||||||
Travel switch |
A travel switch is installed on the furnace door. When the furnace door is opened, the power supply is automatically cut off to prevent the electric shock from being caught when the heating element is hit. |
1 Standard exported package: Internal anticollision protection, external export wooden box packaging.
2 Shipping by express, by air, by sea according to customers' requirements to find the most suitable way.
3 Responsible for the damage during the shipping process, will change the damage part for you for free.