HWB A-18 Wall hung boiler and water heater features superior temperature stablility and user-friendly backlit LCD display.
The unit has a wide power range in 7 sizes 18kW 20kW 24kW 28kW 32kw 36kW 40kW, to meet all of your heating and hot water needs, whilst doing so efficiently.
KEY FACTS AND BENEFITS
TECHNICAL DATA
Model |
HWB-A18-18P HWB-A18-18D |
HWB-A18-20P HWB-A18-20D |
HWB-A18-24P HWB-A18-24D |
HWB-A18-28P HWB-A18-28D |
HWB-A18-32P HWB-A18-32D |
HWB-A18-34P HWB-A18-34D |
HWB-A18-40P HWB-A18-40D |
Fuel Type | Natural gas /LPG /Town gas | ||||||
Rated gas pressure(Pa) | 2000(Natural gas) /2800(LPG) /1000(Town gas) | ||||||
Rated heat load(kW) | 18 | 20 | 24 | 28 | 32 | 36 | 40 |
Heat efficiencty at rated heat load | ≧90% | ≧90% | ≧90% | ≧90% | ≧90% | ≧90% | ≧90% |
Power supply | AC220-50Hz | AC220-50Hz | AC220-50Hz | AC220-50Hz | AC220-50Hz | AC220-50Hz | AC220-50Hz |
Rated electric power (W) | 110 | 110 | 110 | 120 | 120 | 150 | 150 |
Water proof protection | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 |
Central Heating | |||||||
Rated output capacity (kW) | 16.2 | 18 | 21.6 | 25.2 | 28.8 | 32.4 | 36 |
Water temperature range (℃) | Radiator: 30-80; Underfloor heating: 30-60 | ||||||
Heating area (sq.M) | 50-120 | 70-140 | 80-180 | 120-220 | 160-260 | 200-300 | 250-380 |
Water pump lift(m) | 5 | 5 | 5 | 6 | 6 | 7 | 7 |
Water pressure for heating system (MPa) | 0.1-0.3 | 0.1-0.3 | 0.1-0.3 | 0.1-0.3 | 0.1-0.3 | 0.1-0.3 | 0.1-0.3 |
Expansion tank volume (L) | 6 | 6 | 6 | 6 | 6 | 8 | 8 |
Expansion tank preload (MPa) | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 |
Heating system circuit | Sealed and forced | ||||||
Domestic hot water | |||||||
Flow rate △T=25℃(kg/min) | 9 | 10 | 12 | 14 | 16 | 18 | 20 |
Flow rate △T=30℃(kg/min) | 7.5 | 8.3 | 10 | 11.7 | 13.7 | 15 | 16.7 |
DHW temperature range(℃) | 30-60 | ||||||
Applicable water pressure(MPa) | 0.03-0.8 | 0.03-0.8 | 0.03-0.8 | 0.03-0.8 | 0.03-0.8 | 0.03-0.8 | 0.03-0.8 |
Min.Startup flow rate(L/min) | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 |
Min.turnoff flow rate(L/min) | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Connector | Heating/gas inlet: G3/4; DHW connector: G1/2 | ||||||
Flue spec (mm) | Coxial double pipes Φ60-Φ100 | ||||||
Flue pipe length (m) | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Net weight (kg) | 32.8 | 32.8 | 33 | 35 | 35 | 39.5 | 39.5 |
Normal working noise (dB) | <45 | <45 | <45 | <45 | <45 | <45 | <45 |
Exhaust type | Balanced forced draught | ||||||
Ignition | Pulse automatic ignition | ||||||
Temperature control method | Gas proportional modulating | ||||||