FOTOVO SMK Series Off Grid Solar System MPPT Solar Charge Controller
Product Description
Advantages
1. MPPT charge mode, conversion efficiency up to 99%.
2.12V/24V/36V/48V battery system automatic recognition, convenient for customers to use.
3. Maximum PV input voltage up to DC150V.
4. Controllers can be connected in unlimited parallels.
5. Charge mode: three stages (fast charge ,constant charge ,floating charge). To extend the life span of the battery
6. Discharge mode: ON/OFF mode, double time control mode, PV voltage control mode, PV voltage+time delay mode and so on .
7. Recommended battery types: sealed lead acid, Vented, Gel, NiCd battery. Other types of the batteries can also be defined, such as lithium battery etc.
8. CE, RoHS, FCC certifications approved, other certifications can also be made based on different requirements.
9. 2 years warranty and 2~10 years extended technical service.
Equipment Parameters
Product Name |
GSC-Wiser |
Style |
MPPT Charge Controller |
Brand |
Greystone |
Colour |
White/Customize |
Material |
Metal |
Place of Product |
Guangdong Province,China |
Net Weight |
9kg |
Packing |
Packed in carton and Shockproof |
Gross Weight | 10kg |
Mode Name |
Wiser |
Model | GSP-50A | GSP-60A | GSP-70A | GSP-80A | GSP-90A | GSP-100A |
Solar System Voltage | 12V/24V/36V/48V auto work | |||||
Electrical | ||||||
Max PV Input Power | 12V 700W | 12V 900W | 12V 1000W | 12V 1200W | 12V 1300W | 12V 1400W |
24V 1400W | 24V 1800W | 24V 2000W | 24V 2300W | 24V 2600W | 24V 2800W | |
36V 2200W | 36V 2600W | 36V 3000W | 36V 3300W | 36V 3800W | 36V 4200W | |
48V 2900W | 48V 3400W | 48V 4000W | 48V 4600W | 48V 5000W | 48V 5400W | |
Rated Output Current | 50A | 60A | 70A | 80A | 90A | 100A |
Rated DC Load Current | 60A | |||||
Self Consumption | 3W | |||||
Max.Conversion Efficiency | 98.50% | |||||
Protection | PV array short circuit,over charging,battery reverse polarity,output short circuit | |||||
Battery Charging | ||||||
Battery Type | Sealed Gel AGM Flooded Lithium | |||||
Charge Algorithm | 4 stage:Bulk,Absorption,Float,Equalize charging | |||||
Bulk Charge Voltage | Sealed :14.4V AGM 14.2V Gel:14.2V Flooded:14.6V User defined:10-15V | |||||
Float Charger Voltage | Sealed:14.6v AGM:14.8V Flooed:14.9V | |||||
Load disconnect voltage | 10.5V~12V adjustable | |||||
Load reconnect voltage | 12.5V | |||||
Temperature Compensation | 5mV/℃/2V with BTS | |||||
Communication | ||||||
Communication Port | Rs485 (standard)Ethernet RS232 Optional with online monltoring system | |||||
Physical | ||||||
Net weight | 6.5kg | 6.5kg | 7.8kg | 7.8kg | 9kg | 9kg |
Gross weight | 7.3kg | 7.3kg | 8.7kg | 8.7kg | 10kg | 10kg |
Dimension(mm) | 310*230*110 | 370*230*110 | 405*230*110 | |||
Cooling | Heatsink cooling | |||||
Enclosure | IP 45 | |||||
Environment | ||||||
Ambient Operating | —25℃-60℃ | |||||
Temperature | ||||||
Storage Temperature | —40℃-80℃ | |||||
Humidity | 5%-95% non-condensing | |||||
Warranty | 2 years |
Factory and Delivery
FAQ
1. Where can I review the products parameter and manual before purchasing?
A: Related files can be found through through official website - Download.
2. Can you provide OEM or ODM service for customers?
A: Yes. Customers should provide formal Letter of Authorization. We will keep our partnership strictly confidential and customized products will be not sold to any third party.
3. Can MPPT charge controller charge lithium battery? How to set it?
A: Yes. All series controllers can set up “User-defined” battery type for lithium battery by APP or PC software. Galaxy, Master, Mars series can be reset battery type on controller itself, too.
4. How to set up the parameter to charge lithium battery?
A:At present, the MPPT controller charging is mainly designed for the traditional conventional battery pack (12V is composed of serial and parallel series), and the battery system is automatically identified according to the battery voltage. Therefore, if the lithium battery pack needs to be charged, it needs to be converted into a conventional battery. Group, the conversion method is as follows:
The nominal voltage of the lithium battery pack is between 9~15V, just like the 12V conventional battery pack, the internal
calculation ratio is=1;
The nominal voltage of the lithium battery pack is between 18~30V, just like the 24V conventional battery pack, the internal
calculation ratio is 2;
The nominal voltage of the lithium battery pack is between 32~40V, just like the 36V conventional battery pack, the internal
calculation ratio is 3;
The nominal voltage of the lithium battery pack is between 42~60V, just like the 48V conventional battery pack, the internal
calculation ratio is 4;
The nominal voltage of the lithium battery pack is between 72 and 120V, just like the 96V conventional battery pack, the internal
calculation ratio is 8;
The nominal voltage of the lithium battery pack is between 144~240V, just like the 192V conventional battery pack, the internal
calculation ratio is 16;
At the same time, there are two main parameters for battery charging, one is the main charging voltage value and the other is the
floating charging voltage value; so please check the main charging voltage value of the lithium battery pack first, and the
lithium battery pack has no floating charging pressure value, so it is recommended Set the float voltage value ≤ main charge
voltage value -- (0~0.3V)
For example, the parameters of a user's lithium battery pack are as follows: the nominal voltage is 48.1V (consisting of 13 3.7V
cells in series), and the maximum charge cut-off voltage is 54.6V (4.2V*13) (this parameter refers to Main charging voltage),
The steps for setting the MPPT controller parameters for the lithium battery pack are:
1). Calculate the conventional battery pack corresponding to the lithium battery pack, and the internal calculation ratio; 48.1V
is between 42~60V, just like the 48V conventional battery pack, the internal calculation ratio is 4;
2). Set the battery type to Custom Type User defined
3). Set the main charging voltage value = 13.65V (54.6V/4=13.65V; internal calculation magnification = 4)
4). Set the float voltage value between 13.33 and 13.65; (the main charge voltage is 13.65V-(0~0.3V)
The above settings can be made by the host computer, WiFi module, or controller (requires the model that can be set)
5. Is there a setting on the controller to tell it whether the batteries are sealed lead-acid or gel?
A: Yes, all of our MPPT charge controller can be checked and set up the conventional battery types (Sealed/Gel/Flooded) by LCD screen, APP and even PC software.