ETCR9100 H/L Voltage Clamp Current Meter AC 0.00mA~600A

Sales ETCR9100 H/L Voltage Clamp Current Meter AC 0.00mA~600A

H/L voltage AC leakage current and current measurement below 60KV. (Above 600V operate with insulation rods).



1. Model No.: ETCR9100

2. Current Range: AC 0.00mA~600A

3. Resolution: 0.01mA

4.CT Size: φ33mm

5. Line Voltage: Below 60kV current test , operate with insulation rods

6. Power Supply: 6VDC (LR03 × 4pcs alkaline dry batteries)


Product Detail  

ETCR9100 H/L Voltage Clamp Leakage Current Meter break through the traditional structure, specially used to measure the leakage state of high voltage circuit line and judge the running state of zinc oxide arrester. It adopts CT and shielding technology, and is composed of special high voltage detector and high voltage insulation rod.


ETCR9100  H/L Voltage Clamp Leakage Current Meter, the innovative integrated design of the clamp and the guide area ensures the high accuracy, high reliability and high stability of year-round uninterrupted testing. The insulation rod is light, with moistureproof, high temperature resistance, shock resistance, bending resistance, and high insulation and telescopic and others features.


ETCR9100 Series H/L Voltage Clamp Leakage Current Meter connect with insulation rod, which can use for high voltage line current measurement of the wire with insulation skin below 60KV or bare wire below 35KV, online current measurements, also with peak hold, data hold and data storage and so on others functions, the special clamp current meter convenient to clamp or withdraw the tested wire operate by push or pull back the insulation rod, save time and convenient. It is widely used in substations, power plants, and industrial and mining enterprises, inspection stations, electrical maintenance departments for current detection and electrical field operations. It also can replace the H/L voltage transformation ratio tester, which can measure the H/L voltage current of the primary circuit and the secondary circuit respectively, and then calculate the H/L voltage transformation ratio. The insulation rod is light, has the characteristics of moisture-proof, high temperature resistance, impact resistance, bending resistance, high insulation, scalable and so on.


ETCR9100 H/L Voltage Clamp Leakage Current Meter can be used as high and low voltage current transformer ratio tester, zinc oxide arrester tester, which is measured the current in the primary and secondary circuits of the CT respectively, and then calculated out the turns ratio or conversion turns ratio of the CT. Note: due to the running of surge arrester leakage current should be less than 500ua, so it can according to the measurement of arrester leakage situation to judge the running situation of surge arrester, if the measured current of lightning arrester leakage  is too large, more than 500ua, excluding system voltage is too high, the lightning arrester may have stains or be affected with damp or aging. The larger of the leakage current, and the situation of stains or be affected with damp or aging are more serious.

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
X

Home

Supplier

Leave a message

Leave a message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.