Double Output Dual Control Lighting With Sterilization Lamp Microwave Sensor
Features of ON/OFF Switch Sensor:
1. 5.8GHz microwave motion induction control switch.
2. Duble output control
3. Smart detached design,the sensor can be small to fit into the LED PCB board.
4. Supports DIP switch programming and remote control.
5. The detection angle is less than 150° for wall-mounted installation;The ceiling installation is 360°
6. IP 20 with 3 years warranty.
Product Description of ON/OFF Switch Sensor:
Input
|
Operating voltage
|
120-277VAC,50Hz/60Hz
|
Stand-by consumption
|
≤0.5W
|
Output
|
Load capacity
|
Capacitive load 100W; Resistive load 300W
|
Output control method
|
ON/OFF
|
Output L1 road, control lamp; Output L2 channel, control disinfection lamp
|
Sensor Parameters
|
For floodlight
|
Detectio area:50%/100%
|
Hold time:5s/90s/5min/10min
|
Daylight threshold:2Lux/10Lux/50Lux/Disable
|
For sterilamp
|
Delay the light setting:5s/90s/5min/10min
|
Delay turning off light Settings:30min/1H/2H/+∞
|
Microwave Frequency
|
5.8GHz±75MHz
|
Microwave Power
|
<0.3mW
|
Mounting Height
|
2.5-6m /8.2-19.68ft(Ceiling Mounted)
|
Detection Range
|
Radius4-8m/13.12-26.24ft(Ceiling Mounted)
|
Motion Detection
|
0.5m/s
|
Others
|
Detection angle
|
Less than 150° for wall-mounted installation,the ceiling installation is 360°
|
Temperature
|
-30°C~+60°C
|
IP Grade
|
IP 20
|
Certificate
|
RoHS CE
|
Warranty
|
3 years
|
Packing parameters
|
Product net weight
|
0.088kg
|
manner of packing
|
Products with air bags, cardboard compartments packing, 16 / layer, 6 / layer box
|
carton size
|
40*30*24cm
|
Gross weight
|
9.16kg
|
Remark
|
1.Factory Default Setting: Detection area 100%/ Hold time 5s/ Daylight threshold Disable/Delay turn on time 5s/ delay turn off time 30min
2.The product also comes with remote control Settings
3.Tester requirements: a. Height: 1.6m, weight: 65kg, straight walking speed: 0.5/s;
b. Built-in installation of lamps, installation height: 3m high ceiling installation, indoor test results, the actual test data shall be subject to the customer's actual test.
|
ON/OFF Control Detection Area Daylight Threshold Remote Control
Warranty 3 years Hold Time Stand-by period
Detection Range of ON/OFF Switch Sensor
This figure indicates the maximum distance at the highest mounting height with 100% sensitivity.
Typical installation height 2.5-6m.
Mechanical structure of ON/OFF Switch Sensor
Output L1 road, control lamp; Output L2 channel, control disinfection lamp
Wiring diagram of ON/OFF Switch Sensor
Dimensions of ON/OFF Switch Sensor(mm)
Settings of ON/OFF Switch Sensor:
By selecting the combination of the DIP switches,sensor will be precisely set for different applications.
Detection area:
In this area,movement will be detected and able to trigger the sensor,100% detection area is also known as the strong sensitivity.
Hold time:
The period of light keeping 100% brightness after moving object leave the detection area.
Daylight threshold:
Detect ambient brightness and keep daylight priority to motion. Motion detect prioritily if set to "Disable".
Work time:
The period that sterilamp keep ON.
Hold Time Before Light ON:
The period before light ON after the sterilamp starts.
Mode Setting:
UP to control both of L1&L2; DOWN to control L1 only.
The combination of each DIP switch is programmed as shown below:
(1) detection area
(2,3) hold time(LED Light)
(4,5) Daylight threshold
(6,7) Work time (Sterilamp)
(8) Hold time before light ON (Sterilamp)
(9) Output Mode
Installation Method of ON/OFF Switch Sensor:
Application Demo of ON/OFF Switch Sensor
(The following Settings are for DIP switch. For more Settings, please refer to the HD03R remote)
1.In LED Light mode, its detection range/hold time/daylight threshold works at different DIP switch Settings as follows.
(1). When daylight threshold is set to 2lux/5lux/10lux.Ambient brightness is lower than preset lux value, Light ON when detect motion and Light OFF automatically after leaving.
With sufficient daylight, With insufficient daylight, After the last detection and even when motion detected, when motion detected, light ON. the present hold time light remains OFF. elapsed, light OFF.
2. No daylight function
The daylight threshold is set to "Disable".
Light on when detect movement, After people leave, Light off after stand-by period.
Applications: Dim places such as Basement Parking, Underpass.
Light ON automatically once After people leave the detection After the last detection and detect any motion area, light remains 100% the present hold time brightness within hold time. elapsed, light OFF.
2. When it's dual output mode, LED light work priority to sterilamp. Sterilamp start to work only after LED light en work. It works at different DIP switch Settings as follows.
Output L1 is LED Light, output L2 is Sterilamp.
Remarks:
1.Trigger sterilamp to turn into work mode under three conditions:
-
When ambient lux is lower than preset lux value, LED light ON once detect movement, then sterilamp turn into work mode when LED light turn off after the hold time;
-
When ambient lux is higher than preset lux value, L1 output would be shut down and keep LED light OFF, sterilamp turn into work mode after people leave;
-
When work time is set to be "+∞", sterilamp won't turn off automatically until the microwave sensor detect any movement.
2.When detect movement, LED light start to work and sterilamp turn off , the sterilamp work time will be retimed when turn into work after people leave. To say when it change from L2 to L1 mode, the work time would be retimed when back to L2 mode.
3.The sterilamp couldn't detect daylight.
4.When power on, LED light will need 10s before turn on and sterilamp will not.
1.When ambient lux>2lux/10lux/50lux, hold time is set to 5s/90s/5min/10min; hold time before sterilamp turn on is set to 5s/10min, work time is set to 30min/1H/2H ;
With sufficient daylight Sterilamp will turn into Sterilamp work time Sterilamp OFF after the even when motion work mode when could be set to work time until the next detected, light sensor don't detect 30min/1H/ 2H round start when the
remains OFF. any movement after sensor detect movement.
people leave. Hold time could be set to 5s/10min.
2.When ambient lux<2lux/10lux/50lux, hold time is set to 5s/90s/5min/10min; hold time before sterilamp turn on is set to 5s/10min, work time is set to 30min/1H/2H ;
With insufficient Light remains 100% Sterilamp will turn into Sterilamp work time daylight, when motion brightness within workmode when sensor could be set to detected, LED hold time after people don’t detect any 30min/1H/2H.
light ON. leaave the detection movement after people
area. leave. Hold time could be set to 5s/10min.
Sterilamp OFF after the work time until the next round start when the sensor detect movement.
3. When daylight threshold is set to “Disable”, hold time is set to 5s/90s/5min/10min; hold time before sterilamp turn on is set to 5s/10min, work time is set to 30min/1H/2H ;
LED light ON when Sterilamp will turn Sterilamp work time Sterilamp OFF after the people approach into work mode when could be set to 30min work time until the (sensor detect sensor don’t detect /1H/2H. next round start movement). any movement after when the sensor
people leave. Hold detect movement.
time could be set to 5s/10min.
4. When daylight threshold is set to 2lux/10lux/50lux/Disable;Sterilamp work time is set to “+∞” , sterilamp won’t turn off until the sensor detect movement;
Sterilamp keep ON Sterilamp turn off when If LED light ON when Sterilamp will keep ON
when no movement detect movement,the people approach, until the sensor detect detected. sensor will control the the light will keep movement, then turn LED light to be ON/OFF 100% brightness off. Followed by based on the daylight during hold time recycling.
threshold setting(Refer after people leave.
to point 1/2/3 above). Otherwise sterilamp start to work after people leave.
HD03R Remote Control Keys Function Introduction
Attention:
1. Please read the instructions carefully before using this product and keep it well for all users to read at any time.
2. The sensor should be installed by qualified electrician and ensure power is off before the installation.
3. We reserve the right to modify any incorrect text, image and necessary technical parameters.
4. Any unauthorized modification is forbidden, otherwise all guarantees will be immediately invalid.
Installation precautions:
1. Microwave sensor can be installed in any lamp except the one with full metal shell.
2. The detected surface cannot be shielded by metal objects.
3. Make sure the microwave module is completely exposed outside.
4. The detection surface of the sensor module shall be installed facing the detection area.
5. Should be kept away from the driver to avoid interference generation and lamp flashing.
6. Wiring must be strictly in accordance with the wiring diagram to avoid short circuit.
Application Environment:
1. Suitable for indoor installation to avoid false triggering due to external factors such as rain, wind or tree swing.
2. Shall not be installed in the place with all four metal shelters and small space (such as galvanized-iron roof ).
3. Shall note be mounted installation, so as to avoid false trigger caused by the lamp itself shaking.
4. Shall not be installed next to large operating machines such as ventilator/ceiling fan to avoid false triggering caused by machine vibration.
User Notes:
1.Microwave can penetrate walls or glass thinner than 20cm and attenuate if thicker than 20cm.
2. The driver voltage shall be stable and float within 10%.
3. Detection area will be affected by speed of motion, mounting height and movement volume.
4. Conduct test on sunny days without the lampshade which will affect the tested lux value.