Measurement of High/Low voltage AC leakage current and current. (Above 600V, operate with insulation rod). 1. Model No.: ETCR9000S 2. Current Range: AC 0mA~1200A 3. Resolution: 1mA 4.Data Storage: 99 Groups 5. Line Voltage: Below 10kV current test , operate with insulation rods 6. Power Supply: 6VDC (LR03 × 4pcs alkaline dry batteries)
Measurement of DC current and voltage、AC current & voltage true RMS, resistance, surge, capacitance, frequency, on-off test, temperature, diode forward voltage drop and others parameters. 1. Model No. : ETCR6450 2. DC Voltage : 400mV/4V/40V/400V/1000V 3. AC Voltage : 400mV/4V/40V/400V/700V 4. AC Current : 4A/40A/400A/1000A 5. Resistance : 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ 6. Power Supply : 6F22 9VX1
Measurement of H/L voltage AC current below 110kV. (Above 600V, operate with insulation rod). 1. Model No.: ETCR9000 2. Current Range: AC 0mA~1200A 3. Resolution: 1mA 4.Data Storage: 99 Groups 5. Line Voltage: Below 110kV current test , operate with insulation rods 6. Power Supply: 6VDC (LR03 × 4pcs alkaline dry batteries)
High Voltage Insulation Resistance Tester applied to insulation resistance testing of cable, motor, generator, transformer, mutual inductor, high voltage switch, arrester and other large equipment. Insulation resistance measurement (IR); polarization index measurement (PI); absorption ratio (DAR); ramp test mode(RAMP) ; filtered resistance test (FR); Voltage measurement(V); current measurement(nA) 1. Model No.: ETCR3500 2.. Rated Voltage: 250v~5Kv 3.. Insulation Resistance Range: 0.5MΩ~2TΩ 4. Voltage Range: AC/DC 0~1000V 5. Output Short Circuit Current: ≥5mA MAX 6.Power Supply: Rechargeable lithium battery pack 5200mAh
Detecting of AC current, phase, power energy, power, and power factor, harmonic etc. Apply to oscilloscope, harmonic analyzer, Power fault analyzer and other industrial control devices 1. Model No.;ETCR068A 2. Range:0.00A ~ 800A 3. Turn Ratio/Output Voltage:2000:1 / 0~3V(7.5Ω) 4. Resolution : 0.01A 5. Accuracy Class : 0.5 6. CT Size:Φ68mm
Measure three-phase AC voltage, leakage current, current, active power, reactive power, apparent power, total power, phase between current and voltage, phase between phase voltage, frequency, electric energy, phase sequence, etc. 1. Model No.: ETCR7300 2. Measurement of AC current, leakage current, Range: 0.00mA~1200A 3. Measurement of three phase AC voltage, Range: 0.00V~600V 4. Measurement of phase between UI and UU, Range: 0.0°~360° 5. Measurement of active power, reactive power, apparent power, power factor, total power, frequency, phase sequence, electrical energy and other parameters 6. Power Supply : 6V DC(LR6×4 alkaline dry batteries)
Arm Type High Voltage Approach Electric Alarm, after the operator wears the alarm, and close to the high voltage charged body for a certain distance, the alarm will send out a sound and light alarm according to the safety distance of the corresponding voltage level to remind the electrical worker to pay attention to safety and avoid high voltage electric shock accident. This product can also be used for line fault detection and electroscope. 1. Model No.: ETCR1870 2. Alarm Voltage Range : 1kV~500kV 3. Electricity Testing Mode : Non-contact mode 4. Detection Mode : Automatic trigger 5. Max. Alarm Distance: 5.5m 6. Power Supply: CR1632(140mAH)button cell
Measurement of High/Low voltage AC current below 60kV. (Above 600V, operate with insulation rod). 1. Model No.: ETCR9220 2. Current Range: AC 0.00mA~60A 3. Resolution: 0.01mA 4.CT Size: φ68mm 5. Line Voltage: Bperate with insulation rods below 60kV current test 6. Power Supply: 6VDC (LR03 × 4pcs alkaline dry batteries)
Portable Microhmmeter apply to measure the wire resistance of cables, the contact resistance of switches, connectors and relays, the DC resistance of coils, motors and transformers windings, and the connection resistance of the connecting conductor between the metal riveting, the metal components, the ground grid and the ground pole, etc. 1. Model No.: ETCR3640 2. Measurement Range: 1uΩ~200Ω 3. Detection Mode: AC/DC 2 channel simultaneous detection 4. Data Storage: 200 groups 5. Backlight Function : Yes, suitable to the dim place 6. Power Supply: DC 3.7V 7000mAH rechargeable lithium battery
Helmet Type High Voltage Approach Electric Alarm, after the operator wears the alarm, and close to the high voltage charged body for a certain distance, the alarm will send out a sound and light alarm according to the safety distance of the corresponding voltage level to remind the electrical worker to pay attention to safety and avoid high voltage electric shock accident. This product can also be used for line fault detection and electroscope. 1. Model No.: ETCR1880 2. Alarm Voltage Range : 1kV~500kV 3. Electricity Testing Mode : Non-contact mode 4. Detection Mode : Automatic trigger 5. Max. Alarm Distance: 5.5m 6. Power Supply: CR1632(140mAH)button cell
Testing leakage operating time of various leakage protector. 1. Model No.: ETCR8600 2. Leakage Current Range : 15mA~500mA (10 gears) 3.Leakage Operating Time: 0ms~999ms 4. Line Voltage Measurement: Below 250V 5. Test Mode: Manual or Automatic 6. Power Supply: DC 6V LR03 1.5VX4PCS
Measurement of AC leakage current,current. 1. Model No. : ETCR7000B 2. Current Range : 0.0A~2500A 3. CT Size : 80mm×80mm 4. Data Storage : 99 groups 5. Working Current : Open backlight 50mA; close backlight 25mA 6. Power Supply : 6V DC(LR6×4 alkaline dry batteries)
Measurement of primary and secondary current, transformation ratio, phase difference, polarity and phase sequence of current transformers and transformers below 35kV 1. Model No.: ETCR9500C-008 2. Primary Current Test Accuracy : 0.0A~800A/0.1A/±0.5%FS 3. Secondary Current Test Accuracy: 0.00mA~5A/ 0.01mA/ ±0.5%FS 4. Turn Ratio Measurement Range: 1~500 5. Transmission Distance: Primary: 100m; Seconary: 2m cable 6. Power Supply: DC6V alkaline batteries (1.5V AAA × 8)
Measurement of AC leakage current, AC current. 1. Model No.: ETCR6500 2. Range: 0.01mA~300.0A 3. Resolution : 0.01mA 4. Data Storage : 99 groups 5. Working Current : 5mA 6. Power Supply : Alkaline battery 6LR61 9V
On-line testing the equipotential bonding resistance, DC resistance, contact resistance, riveting resistance, etcEquipotential Bonding Reistance On-line Tester apply for on-line testing the equipotential bonding resistance, DC resistance, contact resistance, riveting resistance, etc. 1.Model No.: ETCR3740 2. Measurement Range: 1mΩ~1000Ω 3. Max Test Current: ≥1A 4. Measurment Time: About 30 seconds/times 5. Communication Mode: RS485 6. Power Supply : 12V±1V DC(External power supply)
Detecting of AC current, phase, power energy, power, and power factor, harmonic etc. Apply to oscilloscope, harmonic analyzer, Power fault analyzer and other industrial control devices 1. Range :0.00A~300A 2. Turn Ratio/Output Voltage : 3000:1 /0~3V(30Ω) 3. Resolution : 0.01A 4. Accuracy Class : 0.5 5. Safety class : CATⅢ600V 6. Clamp Size :25mm×30mm
Measurement of DC current,AC current. 1. Midel No. : ETCR6800D 2. Range : DC 0.0A~2000A,AC 0.0A~1500A 3. Working Current : 10mA 4. Data Storage : 99 groups 5. Communication Interface : USB, storage data can be uploaded to computer save and print 6. Power Supply : Alkaline battery 6LR61 9V
Leakage current, current, transformation ratio, ratio difference, angle difference, phase difference and polarity test of current transformer primary & secondary circuits in 380V/220V power distribution system. 1. Model No.:ETCR9620B 2. Primary Current Test Accuracy: 0.0A~3000A/ 0.1A/ ±1%FS 3. Secondary Current Test Accuracy : 0.00mA~5A/ 0.01mA/ ±0.5%FS 4. Turn Ratio Measurement Range: 1~500 5. Wireless Transmission Distance: 100M 6. Power Supply : Alkaline batteries (1.5V AAA X 4PCS & 6F22 9V X1PCS)
Measurement of AC leakage current,large current. 1. Model No.:ETCR7100A 2. Current Range : AC 0.0mA~4000A 3. Data Storage : 99units 4. Frequency : 50Hz ,60Hz automatic identification 5. Sampling Rate : 2 times/second 6. Power Supply : 6V DC(LR6×4 alkaline dry batteries)