AC large current, high harmonic current, phase, electric energy, power, power factor and other industrial electricity consumption and electricity metering detection. Apply for industrial control device, oscilloscope, harmonic analyzer, path analyzer, double clamp earth resistance tester, cable fault tester, power quality analyzer. 1. Model No. : ETCR070A 2. Input Current Range : 0A~1000A 3. Output Signal : 1A~5A 4. Frequency : 40Hz~1kHz 5. Accuracy Class : 0.5 6. CT Size : Φ70mm
H/L voltage AC leakage current and current measurement below 60KV. (Above 600V operate with insulation rods). 1. Model No.: ETCR9100 2. Current Range: AC 0.00mA~600A 3. Resolution: 0.01mA 4.CT Size: φ33mm 5. Line Voltage: Below 60kV current test , operate with insulation rods 6. Power Supply: 6VDC (LR03 × 4pcs alkaline dry batteries)
Measurement of AC leakage current, current, higher harmonic current, phase, power energy, power factor. 1. Model No. : ETCR015 2. Range : 0.00mA ~ 100A 3. Clamp Size:17mm×18mm 4. Weight :175g 5. Safety Class : CATⅢ600V 6. Working Temperature : -15°C~50°C
In the case of the tested circuit is not open-loop, measure two AC voltages, current, phase between voltages, phase between currents, phase, frequency, phase sequence, active power, reactive power, apparent power, and power factor between voltage and current. Discriminate the transformer wiring group, inductive and capacitive circuits, test the secondary circuit and the busbar protection system, read the phase relationship between the CTs of the differential protection groups, check the wiring of the meter for correctness, and repair the line equipment, etc. 1. Model No.: ETCR4020 2. Simultaneous Measurement of Two Channel AC Current Range : 0mA~600A 3. Simultaneous Measurement of Two Channel AC Voltage Range: 0.00V~600V 4. Simultaneous Phase Test Between UI, II and UU Range : 0.0°~360.0° 5. Frequency Range: 45.00Hz~65.00Hz 6. Power Supply : DC9V Alkaline battery LR61.5V AAX6PCS
Multifunction Three-Phase Phase Voltammeter can measure the voltage amplitude, current amplitude, voltage phase, current phase, the phase between voltage and current, frequency, power, active power, reactive power,harmonic and so on parameters at the same time. 1. Model No.: ETCR4400 2. Current Range: 0.001A-20A 3. Voltage Range: 2V-700V 4. Phase Range: 0°~360° 5. Harmonic range: 2 ~ 21 times 6. Power Supply : DC7.4V, 5200mAH rechargeable lithium battery
Detecting of AC current, phase, power energy, power, and power factor, harmonic etc. Apply to oscilloscope, harmonic analyzer, Power fault analyzer and other industrial control devices 1. Model No.: ETCR080A 2. Range : 0.00A~1000A 3. Turn Ratio/Output Voltage:2000:1 / 0~3V(6Ω) 4. Resolution : 0.01A 5. Accuracy Class : 0.5 8. CT Size:80mm x 80mm
Double Clamp Earth Resistance Tester applied with precise 4-pole, 3-pole and simple 2-pole method, selection method, double clamp method for grounding resistance measurement, The measurement of earth resistance, soil resistivity, earth voltage, AC voltage, grounding lead leakage current, AC current, DC resistance. 1. Model No.: ETCR3200 2. Erth resistance,Range:0.00Ω~30.00kΩ 3. Soil resistivity Range:0.00Ωm~9000kΩm 4. Test Frequency: 128Hz/111Hz/105Hz/94Hz(AFC) 5. Short-circuit Current:AC 20mA max 6. Power Supply:DC 9V (Alkaline dry battery LR14-1.5V )
Detecting of AC current, phase, power energy, power, and power factor, harmonic etc. Apply to oscilloscope, harmonic analyzer, Power fault analyzer and other industrial control devices 1. Model No.: ETCR040A 2. Range :0.00A~500A 3. Turn Ratio/Output Voltage : 4000:1 /0~3V(20Ω) 4. Resolution : 0.01A 5. Accuracy Class :0.5 6. Clamp Size :35mm×40mm
Measurement of DC/AC current. 1. Model No. : ETCR7000D 2. Range : DC: 0.0A~2000A AC: 0.0A~1000A 3. Data Storage : 99 groups 4. Peak Hold : Peak value capture and hold function, long pressHOLD key display peak value 5. Working Current : 20mA 6. Power Supply : DC 6V (LR6×4 alkaline dry batteries)
Simultaneously online monitoring and recording 1 ~ 3 channelAC leakage current and current, used for circuit insulation fault troubleshooting, monitoring intermittent leakage fault, check the happen time of insulation fault and maintenance lines, etc. 1. Model No.: ETCR8300F 2. CT Size: φ50mm~φ1500mm 3. Current Range : AC 0.00A~20.00kA 4. Resolution: AC 10mA 5. Current Clamps Quantity: 1 - 3PCS (optional); 6. Power Supply : Rechargeable lithium battery DC3.7V,2600mAh
Measurement of High/Low voltage AC current below 60kV. (Above 600V, operate with insulation rod). 1. Model No.: ETCR9220B 2. Current Range: AC 0.00mA~60.0A 3. Resolution: 0.01mA 4.CT Size: φ68mm 5. Line Voltage: Operate with insulation rods below 60kV current test 6. Power Supply: 6VDC (LR03 × 8pcs alkaline dry batteries)
Measurement of High/Low voltage AC current below 60kV. (Above 600V, operate with insulation rod). 1. Model No.: ETCR9200B 2. Current Range: AC 0mA~1200A 3. Resolution: 1mA 4.CT Size: φ68mm 5. Line Voltage: Below 60kV current test , operate with insulation rods 6. Power Supply: 6VDC (LR03 × 8pcs alkaline dry batteries)
Measure three-phase AC voltage, current, active power, reactive power, apparent power, total power,thephase between current and voltage,thephase between phase voltage, frequency, electric energy, phase sequence, etc. 1. Modle No.: ETCR7350 2. Current Measurement Range: AC 0.0A~6000A 3. Voltage Measurement Range:AC 0.01V~600V 4. Active Power Measurement Range:0.00W~3600kW 5. Apparent Power Measurement Range:0.00VA~3600kVA 6. Power Supply : 6V DC(LR03X4PCS)
After the operator wears the alarm, and close to the high voltage charged body for a certain distance, the alarm will send out a sound and light alarm according to the safety distance of the corresponding voltage level to remind the electrical worker to pay attention to safety and avoid high voltage electric shock accident. This product can also be used for line fault detection and electroscope. 1. Model : ETCR1870C 2. Alarm Voltage Range : 40V~1KV(Low voltage alarm) 3. Working Frequency : 50Hz/60Hz 4. Electricity Testing Mode : Non-contact mode 5. Detection Mode : Automatic trigger 6. Power Supply : CR1632(140mAH)button cell2PCS
High/low voltage AC current measurement (operate with insulation rod above 600V). 1. Model No.:ETCR9150B 2. Measure Range : AC 0mA~1200A 3. Max Resolution : 1mA 4. Communication Mode: Wireless, transmission distance 30M 5. Line Voltage : Bare wire test below110kV 6. Power Supply : DC6V dry lithium battery(LR03X4PCS
In the case of the tested circuit is not open-loop, measure two AC voltages, current, phase between voltages, phase between currents, phase, frequency, phase sequence, active power, reactive power, apparent power, and power factor between voltage and current. Discriminate the transformer wiring group, inductive and capacitive circuits, test the secondary circuit and the busbar protection system, read the phase relationship between the CTs of the differential protection groups, check the wiring of the meter for correctness, and repair the line equipment, etc. 1. Model No.: ETCR4000A 2. Simultaneous measurement of two channel AC current, range: 0.0mA~20.0A 3. Simultaneous measurement of two channel AC voltage, range: 0.00V~600V 4. Simultaneous measurement the phase between UU, II, UI, range: 0.0°~360.0° 5. Active power Range:0.0W~12kW 6. Power supply : DC9V Alkaline battery LR61.5V AAX6PCS
After the operator wears the alarm, and close to the high voltage charged body for a certain distance, the alarm will send out a sound and light alarm according to the safety distance of the corresponding voltage level to remind the electrical worker to pay attention to safety and avoid high voltage electric shock accident. This product can also be used for line fault detection and electroscope. 1. Model : ETCR1860C 2. Alarm Voltage Range : 40V~1kV(Low voltage alarm) 3. Working Frequency : 50Hz/60Hz 4. Detection Mode : Automatic trigger 5. Electricity Testing Mode : Non-contact mode 6. Power Supply : CR1632(140mAH)button cell 1PCS
Measurement of AC leakage current,large current. 1. Model No.:ETCR7100 2. Current Range : AC 0.0mA~3200A 3. Data Storage : 99units 4. Frequency : 50Hz ,60Hz automatic identification 5. Sampling Rate : 2 times/second 6. Power Supply : 6V DC(LR6×4 alkaline dry batteries)
Suitable for measuring the insulation resistance,dielectric absorption ratio andpolarization index of electric motor ,cable ,switch,electrical appliance and others electrical equipment and insulation materials. 1. Model No.: ETCR3480B 2. Insulation Resistance Tester:0.1MΩ~400GΩ 3. Voltage Range:AC/DC 0V~750V 4. Rated Voltage:5000V 5. Short Circuit Current:≥2mA MAX 6. Power Supply : DC 1.5V LR14 X 6PCS
H/L voltage AC leakage current and current measurement below 60KV. (Above 600V operate with insulation rods). 1. Model No.: ETCR9100B 2. Current Range: AC 0.00mA~600A 3. Resolution: 0.01mA 4.Communication Mode: Wireless, transmission distance 30M 5. Line Voltage: Current testing below 60kV, operate with insulation rods 6. Power Supply: 6VDC (LR03 × 8pcs alkaline dry batteries)