CNG Daughter Station is built on the area where no natural gas pipeline. CNG which is delivered by road trailers is off-loaded to NGV and stored in the storage tank group of the station.
Daughter Station Compressor:
CNG Daughter Station is built on the area where no natural gas pipeline. CNG which is delivered by road trailers is off-loaded to NGV and stored in the storage tank group of the station.
Features:
Technical Parameters:
Item |
Unit |
Parameters |
Model |
|
VFD-0.32/(30~200)-250 |
Type |
|
V-type air cooling with piston, two stage compressing |
Suction pressure |
MPa |
3.0~20.0 |
Discharge pressure |
MPa |
25 |
Capacity |
Nm3/h |
600~1800 |
Suction temperature |
℃ |
≤40 |
Cooling mode |
|
Air cooling |
Lubrication mode |
|
Tiny oiling |
Equipped power |
KW |
YB2-315M-8 Explosion-proof motor, 75kW (service factor 1.1), 740r/min, 380V, B3 dⅡBT4 |
Coupling mode |
|
Spring direct coupling |
Noise |
dB(A) |
≤75 dB(A) measured at one meter away from the sound-proof enclosure |
Starting mode |
|
Soft starting |
Dimension of sound-proof enclosure |
mm |
~5538×2438×2438 |
Total weight |
KG |
~10,000 |
Package condition |
|
Brand new |
Installation mode |
|
Overall unit mounted, installation outside |