CM-400 Biochemistry Analyzer
Intended Use
CM-400 is a fully automated analyzer intended for the quantitative analysis of the components from human bodily fluids in clinical diagnosis. It is characterized by open reagents, discrete system, emergency priority, random access and an external computer. Operators should read the manual and be familiar with its functions before operating the instrument.
The analyzer consists of the main instrument and the computer. The main instrument is composed of an optical system, reaction system, sample adding system, reagent adding system, cleaning system and mixing system,and the electrolyte module is optional.
This analyzer is intended for the quantitative analysis of chemical components in human serum, plasma, whole blood, urine, and cerebrospinal liquid samples.
Features
Specifications:
Test Principle |
Latex Immunoturbidimetry, Immunoturbidimetry, Colorimetry |
Analysis Method |
Velocity, End-point, Fixed-time |
Test Items |
Up to 78 items at the same time |
Analysis Rate |
Constant Speed 400T/H |
Reaction Time |
12.3 min |
Sample Volume |
2.0-35µL (0.1 µL increment) |
Sample Tray |
90 Sample Positions (including sample, calibrator and controls) Outer: 30 sample positions Median: 30 sample positions Inner: 30 controls and calibrator positions |
Reagent |
Up to 4 reagents per test item |
Reagent Volume |
R1: 20.0-300.0 µL R2/R3/R4: 0 or 20.0-300.0 µL (1 µL increment) |
Reagent Tray |
Reagent Positions: outer: 40 sample positions inner: 40 sample positions Reagent Bottle Volume: 20 mL, 70 mL Refrigeration: circulating water system
|
Reaction Volume |
120.0-360.0 µL |
Cuvette |
Quartz glass:5*5mm; 90 cuvettes |
Photometry |
Direct Photometry with multiple wavelengths Light Source: 20w halogen lamp, over 2000 hours Spectrometer: grating Detector: photodiode array Wavelengths: support single/double wavelength among 12wavelengths 340, 380, 405, 450, 505, 546, 578, 600, 660, 700, 750, 800nm Points: 82 (every 9 seconds) +2 points for reaction cup blank |
Stir |
High speed stirring, more evenly |
Reaction Temperature |
Constant temperature control (37.0±0.2)°C |
Preheat Time |
20min |
Application |
Calibration: multi-point calibration curve with up to 7 points Dilution: automatic pre-dilution Data Check: basic range check, qualitative judgement |
Dimension |
1160mm(L)*790mm(W)*1140mm(H) |
Max Noise |
58 dB |
Weight |
300kg |
Water Consumption |
No more than 20L purified water per hour |
Liver Function |
TBA, TP, PA, AFU, GPDA, CHE, ALT, GLDH, ADA, AST, ALB, 5’-NT, ALP, TB, LAP, GGT, DB, MAO |
Renal Function |
CRE, cysc, CRE-E, NGAL, BUN, mAlb, UA, NAG,β,-MG |
Specific Protein and Rheumatism |
ASO, CSF, C4, RF, PCT, lgA, CRP, RBP, lgM, hs-CRP, C3, lgG |
Glycometabolism |
GLU, D3-H, GLU-HK, HbA1c, GLU-OX, GA, FMN, LAC |
Blood Lipids and Cardiovascular |
TG, ApoB, ACE, TCH, ApoE, H-FABP, HDL-C, Lp(a), Myo, LDL-C, HCY, cTnl, ApoA1 |
Pancreatitis |
AMY, Lps, α-Amylase |
Venous Thromboembolism and Coagulation |
D-Dimer |
Trace Elements and Electrolytes |
Ca,CO2, Cl, Mg, Fe, K, P, Na, UIBC |
Myocardial Enzyme |
CK, HBDH, CK-MB, LDH1, LDH |