China Inveter Price 50KW 60KW 80KW 4 MPPT 3 Phase Grid-tied Solar inverter
High-yield
Max.efficiency 98.8%
40% compact and lighter
Wide input voltage operation range from 200V to 1100V
All in one. Flexible and economical system solution
Dual MPP trackers
OLED and Touch button
DC Switch
Low maintenance cost
High powered density
Rust-free aluminum covers
Flexible monitorings solution
Small size,Light weight
Intelligent grid management
Reactive power adjustable
Self power reducer when over frequency
Remote active/reactive power limit control
Datasheet
|
80KTL
|
100KTL
|
100KTL-HV
|
125KTL-HV
|
136KTL-HV
|
Max. input voltage
|
1100V
|
||||
Rated input voltage
|
600V
|
600V
|
680V
|
680V
|
680V
|
Start-up voltage
|
200V
|
||||
MPPT operating voltage range
|
180V-1000V
|
||||
Full power MPPT voltage range
|
500V-850V
|
500V-850V
|
550V-850V
|
550V-850V
|
550V-850V
|
Number of MPP trackers
|
8
|
10
|
10
|
10
|
12
|
Number for DC inputs
|
16
|
20
|
20
|
20
|
24
|
Max. input MPPT current
|
26A
|
||||
Max. DC input short circuit current per MPPT
|
40A
|
||||
Output(AC)
|
|||||
Rated power
|
80kW
|
100kW
|
100kW
|
125kW
|
136kW
|
Max.AC power
|
88kVA
|
110kVA
|
110kVA
|
137kVA
|
150kVA
|
Max.output current
|
128A
|
160A
|
128A
|
160A
|
160A
|
Nominal grid voltage
|
3/N/PE, 230V/400Vac 220V/380Vac
|
3/PE, 288V/500Vac
|
3/PE, 288V/500Vac
|
3/PE, 311V/540Vac
|
|
Grid voltage range
|
310Vac-480Vac
|
400Vac-575Vac
|
432Vac-621Vac
|
||
Nominal frequency
|
50/60Hz
|
||||
Grid frequency range
|
45Hz-55Hz/54Hz-66Hz ( According to local standard )
|
||||
Active power adjustable range
|
0~100%
|
||||
THD
|
<3%
|
||||
Power factor
|
1 default(adjustable+/-0.8)
|
||||
Performance
|
|||||
Max efficiency
|
98.6%
|
98.7%
|
98.8%
|
99.00%
|
99.00%
|
European weighted efficiency
|
98.20%
|
98.3%
|
98.5%
|
98.50%
|
98.51%
|
MPPT efficiency
|
>99.9%
|
||||
Protection
|
|||||
DC reverse polarity protection
|
Yes
|
||||
Anti-islanding protection
|
Yes
|
||||
Ground fault monitoring
|
Yes
|
||||
PV-array string fault monitoring
|
Yes
|
||||
Zero voltage ride through
|
Yes
|
||||
DC switch
|
Yes
|
||||
Anti-PID protection
|
Optional
|
||||
AFCI
|
Optional
|
||||
Protection class/ Overvoltage category
|
I/III
|
||||
Input/output SPD
|
PV: type II standard, AC: type II standard
|
||||
Communication
|
|||||
Power mamagement unit
|
According to certification and request
|
||||
Communication
|
RS485, Optional: WiFi /GPRS /PLC
|
||||
Operation data storage
|
25 years
|
||||
General Data
|
|||||
Ambient temperature range
|
-30℃~+60℃
|
||||
Topology
|
Transformerless
|
||||
Degree of protection
|
IP66
|
||||
Allowable relative humidity range
|
0~100%
|
||||
Max.Operating altitude
|
4000m
|
||||
Noise
|
≤60dB
|
||||
Weight
|
72kg
|
84kg
|
72kg
|
84kg
|
85kg
|
Cooling
|
Smart forced air cooling
|
||||
Dimension
|
1051*660*340mm
|
||||
Display
|
LCD&Bluetooth+APP
|
||||
Warranty
|
5 years
|
||||
Standard
|
|||||
EMC
|
EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12
|
||||
Safety standards
|
IEC62109-1/2, IEC62116, IEC61727, IEC-61683, IEC60068(1,2,14,30)
|
||||
Grid standards
|
AS/NZS 4777, VDE V 0124-100, V 0126-1-1, VDE-AR-N 4105, BDEW, CEI 0-21/CEI 0-16, UNE 206 007-1, EN50438/EN50549, G59, EN50530, NB/T32004
|
Grid tie (utility tie) PV systems consist of solar panels and an on grid inverter, without batteries.
The solar panel provides a special inverter that directly converts the DC voltage of the solar panel into an AC power source matching the power grid.
Extra power can sale to local city grid to reduce your home electricity fee.
On-grid inverter specifications include single-phase 220-240v, 50hz; three-phase 380-415V 50hz; single-phase 120v / 240v ,240v 60hz and three-phase 480v.
Our Company Solar Projects for Reference
One stop solution for solar power system.
For more information, please feel free to contact our team
Email: info@greensunpv.com
Whatsapp&Wechat: +86 158 5511 0194