Advantage:
1. Bypass charging function,AC charge available when the unit off
2. 90-280V AC Widely input voltage Grid electricity and battery power priority is optional.
3. Higher charge current and adjustable Communicate with our MPPT charge controller.
4. Intelligent protection, high class of security.
Date Sheet
Model
IVPA3524
IVPA5048
IVPA7548
IVPA10048
Rated Output Power(VA)
3500VA
5000VA
7500VA
10000VA
Rated Output Power(W)
2800W
4000W
6000W
8000W
Nominal DC Input Voltage
24V
48V
48V
48V
Input Voltage Waveform
Sinusoidal(Utility or generator)
Teriminal connection
L N
HOT1 HOT2
Low Line Disconnect
170Vac±7V(UPS)
90Vac±7V(Appliances)
Low Line Re-connect AC Input Range
180Vac±7V(UPS)
100Vac±7V(Appliances)
High Line Disconnect
280Vac±7V
High Line Re-connect
270Vac±7V
Max AC Input Voltage
280Vrms
Nominal Input Frequency
50Hz/60Hz
Low Line Frequency Disconnect
40±1Hz
Low Line Frequency Re-connect
42±1Hz
High Line Frequency Disconnect
65±1Hz
High Line Frequency Re-connect
63±1Hz
Output Voltage Waveform
Synchronize with input voltage
Over-Load Protection(SMPS load)
Over current protector
air switch protection
Over current protector
air switch protection
Output Short Circuit Protection
Over current protector
air switch protection
Over current protector
air switch protection
Efficiency(Line mode)
≥95%
Transfer Time (AC to DC)
15ms (typical value)
Transfer Time (DC toAC)
15ms (typical value)/30ms (special value)
Pass Through Without Battery
NO
Over current Protector (grid)
50A
63A
63A
63A
Utility Charge Mode Specificati
Nominal Input Voltage
80- 140Vac
90-280Vac
Input Voltage Range
Depends On The Battery Type
Nominal Output Voltage
40A
50A
60A
80A
Max Charge Current
0-40A
0-50A
0-60A
0-80A
Charge Current Regulation
Circuit breaker
Battery Initial Voltage
50A
63A
63A
63A
Charger Short Circuit
Dependent on battery type or self-defined
Breaker Size
YES
Product Detail
Installation Procedure:
1. Insure the DC voltage of inverter in accordance with the battery voltage.
2. Insure the positive pole (red)of inverter connect with the positive pole (red) of battery, and the negative pole (black) of inverter connect with the negative pole (black) of battery, then tighten the screw.
3. Turn on the inverter and see if it is good, if good then turn off.
4. Connect with AC power / Ground wire, turn on the inverter and see if it is working normally (charge the battery, show charge current) if so, turn off the inverter.
5. Connect with the load/ground wire and turn on the inverter (Power saver auto or Power saver off ).
6. Turn on the Load.
FQA
Q :Can we use this inverter with AC electricity?
A :Yes, Felicitysolar pure sine wave inverter can hybrid AC, generator, solar, UPS electricity.
Q :If we use DC and AC electricity both, which one will be first?
A :Felicitysolar pure sine wave inverter is AC first.
Q :How about the efficiency of this inverter
A :Felicitysolar pure sine wave inverter has 80% power efficiency.
Q : What kind of certification of this inverter you have?
A :We have many certification, IEC certification by Beide Compliance Loboratory, SONCAP by CIC,etc.